1、Designation: D3673 89 (Reapproved 2009)Standard Test Methods forChemical Analysis of Alpha Olefin Sulfonates1This standard is issued under the fixed designation D3673; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the chemical analysis of alphaolefin sulfonates. The analytical procedures appear in thefollowin
3、g order:SectionsMoisture by the Distillation Method 4-8Sodium Sulfate 9-14Neutral Oil 15-19Chlorides Calculated as Sodium Chloride (NaCl) 20-24Alkalinity 25-29pH 30 and 31Determination of Color 32-37Determination of Active Content by Methylene Blue Titration 38-471.2 The values stated in SI units ar
4、e to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
5、 and determine the applica-bility of regulatory limitations prior to use. For specificprecaution statement see 36.1. Material safety data sheets areavailable for reagents and materials. Review them for hazardsprior to usage.2. Referenced Documents2.1 ASTM Standards:2D1172 Guide for pH of Aqueous Sol
6、utions of Soaps andDetergentsD1193 Specification for Reagent WaterD1209 Test Method for Color of Clear Liquids (Platinum-Cobalt Scale)D3049 Test Method for Synthetic Anionic Ingredient byCationic Titration3. Purity of Reagents3.1 Reagent-grade chemicals shall be used in all tests.Unless otherwise in
7、dicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.3Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to
8、permit its use without lessening the accuracy ofthe determination.3.2 Unless otherwise indicated, references to water shall beunderstood to mean Type III reagent water conforming toSpecification D1193.MOISTURE BY THE DISTILLATIONMETHOD4. Apparatus4.1 The apparatus required shall consist of a glass f
9、laskheated by suitable means and provided with a reflux condenserdischarging into a trap and connected to the flask. Theconnections between the trap and the condenser and flask shallbe interchangeable ground joints. The trap serves to collect andmeasure the condensed water and to return the solvent
10、to theflask. A suitable assembly of the apparatus is illustrated in Fig.1.4.1.1 Flask, 1-L capacity, either the short-neck, round-bottom type, or the Erlenmeyer type.4.1.2 Heat SourceEither an oil bath (for example, stearicacid or paraffin wax) or an electric heater provided with asliding rheostat o
11、r other means of heat control.4.1.3 CondenserA water-cooled glass reflux condenser(Fig. 1), having a jacket approximately 1534 in. (400 mm) inlength, with an inner tube38 to12 in. (9.5 to 12.7 mm) inoutside diameter, and not less than14 in. (6.35 mm) in insidediameter. The end of the condenser to be
12、 inserted in the trapmay be ground off at an angle of 30 from the vertical axis ofthe condenser. When inserted into the trap, the tip of the1These test methods are under the jurisdiction of ASTM Committee D12 onSoaps and Other Detergents and are the direct responsibility of SubcommitteeD12.12 on Ana
13、lysis and Specifications of Soaps, Synthetics, Detergents and theirComponents.Current edition approved Oct. 1, 2009. Published March 2010. Originallyapproved in 1978. Last previous edition approved in 2003 as D3673 89(2003).DOI: 10.1520/D3673-89R09.2For referenced ASTM standards, visit the ASTM webs
14、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications , AmericanChemical Society, Washington, DC. For sug
15、gestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM Internationa
16、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.condenser shall be about14 in. (7 mm) above the surface of theliquid in the trap after the distillation conditions have beenestablished. Fig. 1 shows a conventional sealed-in type ofcondenser, but any other conden
17、ser fulfilling the detailedrequirements of this paragraph may be used.4.1.4 TrapFor greatest accuracy several trap sizes areallowable, depending upon the percentage of moisture ex-pected:Moisture Expected, % Size of Trap, mL0to5,incl 5Over 5 to 17, incl 10Over 17 to 30, incl 25Over 30 to 50, incl 25
18、Over 50 to 70, incl 25Over 70 to 85, incl 25Traps made of well-annealed glass, constructed essentiallyas shown in Fig. 1, and graduated to contain one of thefollowing specified volumes at 20C shall be used:4.1.4.1 Trap, 5-mL capacity, subdivided into 0.1-mL divi-sions with each 1-mL line numbered (5
19、 mL at top). The errorin any indicated capacity may not be greater than 0.05 mL.4.1.4.2 Trap, 10-mL capacity, subdivided from 0 to 1 mL in0.1-mL divisions and from 1 to 10 mL in 0.2-mL divisions.4.1.4.3 Trap, 25-mL capacity, subdivided from 0 to 1 mL in0.1-mL divisions and from 1 to 25 mL in 0.2-mL
20、divisions.NOTE 1The condenser and trap should be thoroughly cleaned beforeuse.5. Solvent5.1 XyleneSaturate xylene with water by shaking with asmall quantity of water and distill. Use the distillate for thedetermination.6. Procedure6.1 Transfer to the 1000-mL flask (equipped with the size ofthe trap
21、specified in 4.1.4) an amount of sample according tothe percentage of moisture expected, as follows:Moisture Expected, %Weight of Sampleto Be Used, gA0 to 5, incl 50 6 5Over 5 to 17, incl 50 6 5Over 17 to 30, incl 40 6 4Over 30 to 50, incl 30 6 3Over 50 to 70, incl 30 6 3Over 70 to 85, incl 25 6 2AW
22、eighed to the nearest 0.25 g.Immediately add about 250 mL of xylene. Place a small, thinsheet of long-fiber, chemical-resistant glass4wool on thesurface of the xylene. The glass wool should be thoroughlydried in the oven and held in the desiccator before use.6.2 Connect the flask and receiver to the
23、 condenser and poursufficient xylene down the condenser tube to cause a slightoverflow through the side tube. Wrap the flask and tube leadingto the receiver with glass wool, so that refluxing will be underbetter control.6.3 Heat the oil bath with a gas burner or other source ofheat, or apply heat di
24、rectly to the flask with an electric heaterand distill slowly. The rate at the start should be approximately100 drops per minute. When the greater part of the water hasdistilled over, increase the distillation rate to 200 drops perminute until no more water is collected. Rinse during thedistillation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD367319892009STANDARDTESTMETHODSFORCHEMICALANALYSISOFALPHAOLEFINSULFONATES 烯磺酸 盐化 分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515228.html