ASTM D3349-2017 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf
《ASTM D3349-2017 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3349-2017 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3349 17Standard Test Method forAbsorption Coefficient of Ethylene Polymer MaterialPigmented with Carbon Black1This standard is issued under the fixed designation D3349; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method measures the amount of light transmit-ted through a film of carbon black pigmented ethyl
3、ene poly-mer.1.2 After calculation of the amount of light and filmthickness, an absorption coefficient is calculated.1.3 Whenever two sets of values are presented, in differentunits, the values in the first set are the standard, while those inparentheses are for information only.1.4 This standard do
4、es not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Sta
5、ndards:2E60 Practice for Analysis of Metals, Ores, and RelatedMaterials by SpectrophotometryD1248 Specification for Polyethylene Plastics ExtrusionMaterials for Wire and Cable3. Summary of Test Method3.1 The transmission of light of a specified wavelengththrough thin ethylene polymer film is measure
6、d. The result isused to calculate an absorption coefficient that is a reciprocalfunction of transmission after correction for thickness.4. Significance and Use4.1 The absorption coefficient of polyolefin polymer pig-mented with carbon black is useful to judge the degree anduniformity of dispersion o
7、f the pigment, and the adequacy ofthe quantitative level of pigment addition. These factors areused to predict the performance of the polymer material inresponse to prolonged exposure to ultraviolet light as evi-denced by minimal changes in specific properties.NOTE 1This test method was developed to
8、 evaluate ethylene polymermaterials pigmented with small particle size carbon blacks suitable for UVprotection. It is not known how accurate and reproducible the test wouldbe with larger (35 nm or greater) particle size blacks.5. Apparatus5.1 SpectrophotometerAn instrument in accordance withPractice
9、 E60 is required.NOTE 2Consult the spectrophotometers operation manual or consultthe manufacturer of the instrument for the calibration procedure.5.2 MoldA mold in accordance with Figs. 1 and 2. Makethe mold of Ketos steel (or equivalent) hardened to RockwellC45, with mold surfaces chromium plated t
10、o 0.005-mm(0.0002-in.) minimum thickness.5.3 Specimen HolderCut two concentric rings fromphenolic-paper laminate or other suitable material to thedimensions shown in Fig. 3. Slip fit the rings snugly one withinthe other.5.4 Reference MaterialA reference material is requiredhaving an absorbance value
11、 of 1.0 to 1.2 at 375 nm asmeasured by the instrument used for testing.5.4.1 Neutral Density Filter,3M-type carbon 0.85 density,laminated between cellulose acetate sheets has been foundsatisfactory. Since this material is furnished as a rigid sheet, itcannot be mounted as described in Section 7. Ins
12、tead, a specialmount must be prepared by cutting Ring 1 of Fig. 3 in halfaround its circumference to give two rings about 2 mm(0.08 in.) thick. Cut a 22-mm (0.87-in.) circle from thelaminated filter, sandwich this between the two 2-mm rings,and slide the outer ring (Ring 2 of Fig. 3) over this compo
13、site.5.4.2 An alternative reference material can be prepared byany user of this test method. Prepare an alternative reference1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.07 on El
14、ectrical Insulating Materials.Current edition approved March 1, 2017. Published March 2017. Originallyapproved in 1974. Last previous edition approved in 2012 as D3349 12. DOI:10.1520/D3349-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at se
15、rviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of the apparatus known to the committee at this timeis The Kodak neutral density filter, No. 5, available from the Eastman Kodak CoIf you are
16、 aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.*A Summary of Changes section appears at the end of this standardCopyright AST
17、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Stan
18、dards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1material consisting of a highly uniform sample of ASTM TypeI polyethylene (see Specification D1248) containing about 1 %of a 20-nm carbon black (either channel or furnace type). Pres
19、sout a uniform film of this material and mount as in Section 8to meet the above requirements. Reference materials so pre-pared shall show no more than 6 4 % variation from theaverage absorbance value when measured at any point at375 nm in the instrument used for testing.6. Calibration and Standardiz
20、ation6.1 Allow the spectrophotometer to stabilize. Using thespectrophotometer manufacturers instructions, set the zeroand infinity values on the absorbance scale.6.2 Insert the mounted reference material in the spectropho-tometer and place it into the light beam. Read and record theabsorbance value
21、using the conditions that bring the valuenearest to zero on the absorbance scale. With the referencematerial still in the beam, readjust the slit width to bring thereading back to zero. Recheck the infinity value.7. Conditioning7.1 No special conditioning is required.8. Specimen Preparation8.1 Prepa
22、re three test specimens from each lot of materialby hot-pressing the ethylene polymer at a suitable temperaturebetween highly polished plates, such as those shown in Figs. 1and 2, using a charge sufficient to yield a specimen 40 to 50mm in diameter and approximately 0.01 mm in thickness.Double press
23、ing expedites the preparation of satisfactoryspecimens, that is, pressing to approximately 0.05 mm thick-ness and then pressing a section of that sheet to the required0.01 mm thickness. Use of a silicone mold release agent is alsorecommended. For each specimen in turn, carefully transfer thespecimen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33492017STANDARDTESTMETHODFORABSORPTIONCOEFFICIENTOFETHYLENEPOLYMERMATERIALPIGMENTEDWITHCARBONBLACK

链接地址:http://www.mydoc123.com/p-514628.html