ASTM D3349-2012 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf
《ASTM D3349-2012 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3349-2012 Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black《用炭黑着色的乙烯聚合材料吸收系数的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:D334906 Designation: D3349 12An American National StandardStandard Test Method forAbsorption Coefficient of Ethylene Polymer MaterialPigmented with Carbon Black1This standard is issued under the fixed designation D3349; the number immediately following the designation indicates the year
2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method measures the amount of light transmitte
3、d through a film of carbon black pigmented ethylene polymer.1.2 After calculation of the amount of light and film thickness, an absorption coefficient is calculated.1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those inparenthe
4、ses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations p
5、rior to use.2. Referenced Documents2.1 ASTM Standards:2E60 Practice for Analysis of Metals, Ores, and Related Materials by SpectrophotometryD1248 Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable3. Summary of Test Method3.1 The transmission of light of a specified wavele
6、ngth through thin ethylene polymer film is measured. The result is used tocalculate an absorption coefficient that is a reciprocal function of transmission after correction for thickness.4. Significance and Use4.1 The absorption coefficient of polyolefin polymer pigmented with carbon black is useful
7、 to judge the degree and uniformityof dispersion of the pigment, and the adequacy of the quantitative level of pigment addition. These factors are used to predict theperformance of the polymer material in response to prolonged exposure to ultraviolet light as evidenced by minimal changes inspecific
8、properties.NOTE 1This test method was developed to evaluate ethylene polymer materials pigmented with small particle size carbon blacks suitable for UVprotection. It is not known how accurate and reproducible the test would be with larger (35 nm or greater) particle size blacks.5. Apparatus5.1 Spect
9、rophotometerAn instrument in accordance with Practice E60 is required.NOTE 2Consult the spectrophotometers operation manual or consult the manufacturer of the instrument for the calibration procedure.5.2 MoldA mold in accordance with Figs. 1 and 2. Make the mold of Ketos steel (or equivalent) harden
10、ed to Rockwell C45,with mold surfaces chromium plated to 0.005-mm (0.0002-in.) minimum thickness.5.3 Specimen HolderCut two concentric rings from phenolic-paper laminate or other suitable material to the dimensionsshown in Fig. 3. Slip fit the rings snugly one within the other.5.4 Reference Material
11、A reference material is required having an absorbance value of 1.0 to 1.2 at 375 nm as measured bythe instrument used for testing.1This test method is under the jurisdiction of ASTM Committee D09 on Electrical and Electronic Insulating Materials and is the direct responsibility of SubcommitteeD09.18
12、 on Solid Insulations, Non-Metallic Shieldings, and Coverings for Electrical and Telecommunications Wires and Cables.Current edition approved AprilJan. 1, 2006.2012. Published April 2006.February 2012. Originally approved in 1974. Last previous edition approved in 19992006 asD334999.D3349 06. DOI: 1
13、0.1520/D3349-06.10.1520/D3349-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an A
14、STM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In
15、all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4.1 N
16、eutral Density Filter,3M-type carbon 0.85 density, laminated between cellulose acetate sheets has been foundsatisfactory. Since this material is furnished as a rigid sheet, it cannot be mounted as described in Section 7. Instead, a specialmount must be prepared by cutting Ring 1 of Fig. 3 in half ar
17、ound its circumference to give two rings about 2 mm (0.08 in.) thick.Cut a 22-mm (0.87-in.) circle from the laminated filter, sandwich this between the two 2-mm rings, and slide the outer ring (Ring2 of Fig. 3) over this composite.5.4.2 An alternative reference material can be prepared by any user o
18、f this test method. Prepare an alternative reference materialconsisting of a highly uniform sample of ASTM Type I polyethylene (see Specification D1248) containing about 1 % of a 20-nmcarbon black (either channel or furnace type). Press out a uniform film of this material and mount as in Section 8 t
19、o meet the aboverequirements. Reference materials so prepared shall show no more than 6 4 % variation from the average absorbance value whenmeasured at any point at 375 nm in the instrument used for testing.6. Calibration and Standardization6.1 Allow the spectrophotometer to stabilize. Using the spe
20、ctrophotomer manufacturers instructions, set the zero and infinityvalues on the absorbance scale.6.2 Insert the mounted reference material in the spectrophotomer and place it into the light beam. Read and record theabsorbance value using the conditions that bring the value nearest to zero on the abs
21、orbance scale. With the reference material stillin the beam, readjust the slit width to bring the reading back to zero. Recheck the infinity value.7. Conditioning7.1 No special conditioning is required.8. Specimen Preparation8.1 Prepare three test specimens from each lot of material by hot-pressing
22、the ethylene polymer at a suitable temperature3The sole source of supply of the apparatus known to the committee at this time is The Kodak neutral density filter, No. 5, available from the Eastman Kodak Co Ifyou are aware of alternative suppliers, please provide this information to ASTM Internationa
23、l Headquarters. Your comments will receive careful consideration at a meetingof the responsible technical committee, which you may attend.FIG. 1 Mold, Top PlatenD3349 122between highly polished plates, such as those shown in Figs. 1 and 2, using a charge sufficient to yield a specimen 40 to 50 mmin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33492012STANDARDTESTMETHODFORABSORPTIONCOEFFICIENTOFETHYLENEPOLYMERMATERIALPIGMENTEDWITHCARBONBLACK

链接地址:http://www.mydoc123.com/p-514627.html