ASTM D2908-1991(2005) Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography《用水喷射气体色层分离法测量水中的挥发性有机物质》.pdf
《ASTM D2908-1991(2005) Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography《用水喷射气体色层分离法测量水中的挥发性有机物质》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2908-1991(2005) Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography《用水喷射气体色层分离法测量水中的挥发性有机物质》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2908 91 (Reapproved 2005)Standard Practice forMeasuring Volatile Organic Matter in Water by Aqueous-Injection Gas Chromatography1This standard is issued under the fixed designation D 2908; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers general guidance applicable tocertain test methods for the qual
3、itative and quantitative deter-mination of specific organic compounds, or classes of com-pounds, in water by direct aqueous injection gas chromatogra-phy (1, 2, 3, 4).21.2 Volatile organic compounds at aqueous concentrationsgreater than about 1 mg/L can generally be determined bydirect aqueous injec
4、tion gas chromatography.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prio
5、r to use.2. Referenced Documents2.1 ASTM Standards:3D 1129 Terminology Relating to WaterD 1192 Guide for Equipment for Sampling Water andSteam in Closed Conduits4D 1193 Specification for Reagent WaterD 3370 Practices for Sampling Water from Closed ConduitsE 260 Practice for Packed Column Gas Chromat
6、ographyE 355 Practice for Gas Chromatography Terms and Rela-tionships3. Terminology3.1 DefinitionsThe following terms in this practice aredefined in accordance with Terminology D 1129.3.1.1 “ghosting” or memory peaksan interference, show-ing as a peak, which appears at the same elution time as theor
7、ganic component of previous analysis.3.1.2 internal standarda material present in or added tosamples in known amount to serve as a reference measurement.3.1.3 noisean extraneous electronic signal which affectsbaseline stability.3.1.4 relative retention ratiothe retention time of theunknown component
8、 divided by the retention time of theinternal standard.3.1.5 retention timethe time that elapses from the intro-duction of the sample until the peak maximum is reached.3.2 For definitions of other chromatographic terms used inthis practice, refer to Practice E 355.4. Summary of Practice4.1 This prac
9、tice defines the applicability of various col-umns and conditions for the separation of naturally occurringor synthetic organics or both, in an aqueous medium forsubsequent detection with a flame ionization detector. Aftervaporization, the aqueous sample is carried through the columnby an inert carr
10、ier gas. The sample components are partitionedbetween the carrier gas and a stationary liquid phase on an inertsolid support. The column effluent is burned in an air-hydrogenflame. The ions released from combustion of the organiccomponents induce an increase in standing current which ismeasured. Alt
11、hough this method is written for hydrogen flamedetection, the basic technology is applicable to other detectorsif water does not interfere.1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.06 on Methods for Analysis forOrganic
12、 Substances in Water.Current edition approved Dec. 1, 2005. Published January 2006. Originallyapproved in 1970. Last previous edition approved in 2001 as D 2908 91 (2001).2The boldface numbers in parentheses refer to the list of references at the end ofthis practice.3For referenced ASTM standards, v
13、isit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
14、n, PA 19428-2959, United States.4.2 The elution times are characteristic of the variousorganic components present in the sample, while the peak areasare proportional to the quantities of the components. A discus-sion of gas chromatography is presented in Practice E 260.5. Significance and Use5.1 Thi
15、s practice is useful in identifying the major organicconstituents in wastewater for support of effective in-plant orpollution control programs. Currently, the most practical meansfor tentatively identifying and measuring a range of volatileorganic compounds is gas-liquid chromatography. Positiveiden
16、tification requires supplemental testing (for example, mul-tiple columns, speciality detectors, spectroscopy, or a combi-nation of these techniques).6. Interferences6.1 Particulate MatterParticulate or suspended mattershould be removed by centrifugation or membrane filtration ifcomponents of interes
17、t are not altered. This pretreatment willprevent both plugging of syringes and formation of condensa-tion nuclei. Acidification will often facilitate the dissolving ofparticulate matter, but the operator must determine that pHadjustment does not alter the components to be determined.6.2 Identical Re
18、tention TimesWith any given column andoperating conditions, one or more components may elute atidentical retention times. Thus a chromatographic peak is onlypresumptive evidence of a single component. Confirmationrequires analyses with other columns with varying physical andchemical properties, or s
19、pectrometric confirmation of theisolated peak, or both.6.3 AcidificationDetection of certain groups of compo-nents will be enhanced if the sample is made neutral or slightlyacidic. This may minimize the formation of nonvolatile salts incases such as the analysis of volatile organic acids and basesan
20、d certain chlorophenols.6.4 GhostingGhosting is evidenced by an interferencepeak that occurs at the same time as that for a component froma previous analysis but usually with less intensity. Ghostingoccurs because of organic holdup in the injection port. Re-peated Type I water washing with 5-L injec
21、tions betweensample runs will usually eliminate ghosting problems. Thebaseline is checked at maximum sensitivity to assure that theinterference has been eliminated. In addition to water injec-tions, increasing the injection port temperature for a period oftime will often facilitate the elimination o
22、f ghosting problems.6.4.1 Delayed ElutionHighly polar or high boiling com-ponents may unpredictably elute several chromatograms laterand therefore act as an interference. This is particularly truewith complex industrial waste samples. A combination ofrepeated water injections and elevated column tem
23、perature willeliminate this problem. Back flush valves should be used if thisproblem is encountered often.7. Apparatus7.1 Gas System:7.1.1 Gas RegulatorsHigh-quality pressure regulatorsshould be used to ensure a steady flow of gas to the instrument.If temperature programming is used, differential fl
24、ow control-lers should be installed in the carrier gas line to prevent adecrease in flow as the pressure drop across the columnincreases due to the increasing temperature. An unsteady flowwill create an unstable baseline.7.1.2 Gas Transport TubingNew tubing should be washedwith a detergent solution,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD290819912005STANDARDPRACTICEFORMEASURINGVOLATILEORGANICMATTERINWATERBYAQUEOUSINJECTIONGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-513774.html