ASTM D926-2017 Standard Test Method for Rubber Property&x2014 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf
《ASTM D926-2017 Standard Test Method for Rubber Property&x2014 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D926-2017 Standard Test Method for Rubber Property&x2014 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D926 08 (Reapproved 2013)D926 17Standard Test Method forRubber PropertyPlasticity and Recovery (Parallel PlateMethod)1This standard is issued under the fixed designation D926; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test meth
3、od covers the determination of plasticity and recovery of unvulcanized rubber by means of the parallel plateplastometer. Uncompounded, compounded, and reclaim rubber may be tested.NOTE 1ISO 2007 and Test Method D3194 use a principle similar to this test method although the apparatus, test conditions
4、, and procedure aredifferent.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of
5、 this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished
6、in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D3194 Test Method for Rubber From Natural SourcesPlasticity Retention
7、Index (PRI)D3767 Practice for RubberMeasurement of DimensionsD4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing IndustriesE145 Specification for Gravity-Convection and Forced-Ventilation Ovens2.2 ISO Standard:3ISO 2007 Rubber UnvulcanizedDe
8、termination of PlasticityRapid Plastimeter Method3. Summary of Test Method3.1 Plasticity:3.1.1 A specimen of specific volume and height is tested at room temperature or heated to a specified test temperature for 15min and then subjected to a compressive force of 49 N for a specified time.3.1.2 At th
9、e end of this time, the height of the specimen is measured, and the plasticity number is calculated.3.2 RecoveryThere are two recovery procedures.3.2.1 Procedure AThe test specimen is removed from the plastometer immediately after the determination of plasticity andallowed to cool and recover some o
10、f its original height for 1 min. The height is measured again and the recovery is calculated.3.2.2 Procedure BThe test specimen is compressed to a height of 5 mm for 30 s and then allowed to recover at the testtemperature for 5 min. The height is measured again and the recovery is calculated.1 This
11、test method is under the jurisdiction of ASTM committee D11 on Rubber and Rubber-like Materials and is the direct responsibility of Subcommittee D11.12 inProcessability Tests.Current edition approved Nov. 1, 2013Oct. 1, 2017. Published January 2014November 2017. Originally approved in 1956. Last pre
12、vious edition approved in 20082013as D926 08.D926 08 (2013). DOI: 10.1520/D0926-08R13.10.1520/D0926-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards
13、Document Summary page on the ASTM website.3 Available from American National Standards Institute, 25 West 43rd St., 4th Floor, New York, NY 10036.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the pre
14、vious version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM I
15、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Significance and Use4.1 The plasticity number and the recovery of the test specimen are related to the flow properties and the elastic properties,respectively, and may be useful in predicting process
16、ing characteristics, such as ease of forming and extrusion characteristics.4.1.1 In this test method, plasticity is measured in an inverse manner, as noted by the final height of the specimen. Thus, highplasticity rubbers (high degree of flow during test) are indicated by a low plasticity number.5.
17、Apparatus5.1 The essential features of the parallel plate plastometer, illustrated in Fig. 1, are as follows:5.1.1 Two metal plates, not less than 10 mm in thickness and 40 mm in diameter, shall be mounted on a suitable frame so thatone plate moves with respect to the other, and so that the two plat
18、es are parallel within 0.017 rad (1) at all times.5.1.2 The apparatus shall be so designed that a specimen between the parallel plates is subjected to a force of 49 6 0.5 N,including the effect of the spring in the dial gauge during test.5.1.3 A digital or dial indicator gauge calibrated in hundredt
19、hs of a millimetre (0.01 mm) shall be mounted on the apparatusin such a manner that the distance between the plates can be determined at all times.5.1.4 When required, the apparatus shall be operated in any oven, as described in Specification E145, that is capable ofcontaining the plastometer.5.1.5
20、A separate dimensional measurement gauge is required for performing recovery measurements. The apparatus andmethodology described in Practice D3767, Procedure A, shall be employed when performing these measurements.5.2 Test SurfacesFilms or material with low coefficients of friction shall be used to
21、 prevent sticking of the test specimen tothe plates. The most commonly used test surface is polyester film. Other films such as cellophane or nylon may be used. The testsurface film shall have a thickness of 0.25 6 0.005 mm.NOTE 2The test surface used can affect the plasticity number. Even different
22、 grades of the same type of film can cause different results. Whencomparing results, the same test surface must be used.6. Sampling6.1 Samples may be taken from raw rubber or unvulcanized rubber compounds undergoing processing operations.FIG. 1 One Type of Parallel Plate PlastometerD926 1727. Test S
23、pecimens7.1 The specimen shall be a right cylinder 2.00 6 0.02 cm3 in volume and be free from air pockets. (A cylinder 16 mm indiameter and 10 mm in height is appropriate.) The specimen may be prepared from either a solid piece or plied sheets ofunvulcanized rubber approximately 1.5 mm in thickness,
24、 care being taken to exclude air pockets in the sheet. The specimens maybe cut from the sheet either by means of two mating dies conforming to Fig. 2, which produce cylinders of the correct volume,or a rotating die having an internal diameter of approximately 16 mm. If a rotating die is used, the he
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9262017STANDARDTESTMETHODFORRUBBERPROPERTYX2014PLASTICITYANDRECOVERYPARALLELPLATEMETHOD 橡胶 特性 标准

链接地址:http://www.mydoc123.com/p-512521.html