1、Designation: D789 18Standard Test Method forDetermination of Relative Viscosity of ConcentratedPolyamide (PA) Solutions1This standard is issued under the fixed designation D789; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of relativeviscosity as it applies to concentrated solutions of poly
3、amide(PA).1.2 This test method does not address measures of viscosityderived from measurements with dilute solutions.1.3 The values stated in SI units are to be regarded asstandard. The values given in brackets are for information only.1.4 This standard does not purport to address all of thesafety c
4、oncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.NOTE 1This standard and ISO 307 address the same subject, buy t
5、hetechnical content is different.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade
6、Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D446 Specifications and Operating Instructions for GlassCapillary Kinematic ViscometersD883 Terminology Relating to PlasticsD2162 Practice for Basic Calibration of Master Viscometersand Viscosity Oil S
7、tandardsD6779 Classification System for and Basis of Specificationfor Polyamide Molding and Extrusion Materials (PA)E1953 Practice for Description of Thermal Analysis andRheology ApparatusE2975 Test Method for Calibration or Calibration Verifica-tion of Concentric Cylinder Rotational Viscometers2.2
8、ISO Standards:3ISO 307 Determination of Viscosity Number of Polyamidesin Dilute SolutionsISO 16396-1 PlasticsPolyamide (PA) moulding and extru-sion materialsPart 1: Designation system, marking ofproducts and basis for specificationsISO 17025 General Requirements for the Competence ofTesting and Cali
9、bration Laboratories3. Terminology3.1 DefinitionsThe definitions used in these test methodsare in accordance with Terminology D883.4. Significance and Use4.1 These test methods are intended for use as control andacceptance tests. They are also applicable in the partialevaluation of materials for spe
10、cific end uses and as a means fordetecting changes in materials due to specific deterioratingcauses.4.2 The steps involved in running this method are:4.2.1 Calibration of the viscometers,4.2.2 Preparation of solutions,4.2.3 Determination of efflux time,4.2.4 Calculation of relative viscosity (which
11、requires thefollowing),4.2.4.1 Determining the density of the polymer/formic acidsolution, and4.2.4.2 Determining the absolute viscosity of the formicacid used.4.3 Solvents used to prepare concentrated solutions for usein this test method are formic acid (9.2.6.1) and m-cresol(9.2.6.2).4.4 Solvents
12、used to prepare dilute solutions of variouspolyamides are designated in ASTM D6779, ISO 16396, andISO 307. These include:1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materials(Section D20.15.09).C
13、urrent edition approved June 15, 2018. Published July 2018. Originallyapproved in 1944. Last previous edition approved in 2015 as D789 - 15. DOI:10.1520/D0789-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
14、of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyrig
15、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of Internationa
16、l Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.14.4.1 Formic AcidPA 6, PA 46, PA 66, PA 69, PA 610, PAMXD6 and corresponding copolyamides4.4.2 Sulfuric AcidPA6, PA46, PA66, PA69, PA610, PA612, PA MXD6 and corresponding copol
17、yamides4.4.3 m-cresolPA 612, PA1010, PA1012, PA 11, PA 12,PA1212, PA 11/12 copolymers, PA 6T/66, PA 6I/66, PA 6I/6T,PA 6T/6I/66, PA 6T/6I, PA 6I/6T/664.4.4 Phenol/1,1,2,2-tetrachloroethane (where legal)PA6T/66, PA 6I/66, PA 6I/6T, PA 6T/6I/66, PA 6T/6I, PA6I/6T/66, PA 6T/66, PA 6I/66, PA 6I/6T, PA 6
18、T/6I/66, PA6T/6I, PA 10T PA 6I/6T/66, PPA and copolyamides5. Test Specimen5.1 Test specimens for the various tests shall conform to therequirements prescribed herein.6. Number of Tests6.1 One determination shall be considered sufficient fortesting each molding powder batch or resin lot. Table 1 give
19、srepeatability and reproducibility statistics for relative viscositytesting.7. Sampling7.1 The material shall be sampled statistically or the sampleshall come from a process that is in statistical control.7.2 Samples in many forms, such as molded powder,molded shapes, or re-grind are permitted. It i
20、s recommendedthat molded specimens be cut into smaller parts prior to testing.8. Conditioning8.1 Test ConditionsDo not remove samples from sealed,airtight containers until ready for testing.TEST METHOD9. Relative Viscosity9.1 GeneralDetermine the relative viscosity of the poly-amide polymer by ASTM
21、Ubbelohde (Suspended-Level)-typeviscometer. The ASTM Ubbelohde-type viscometer is thereference and referee method. Ostwald-type viscometers, pipetviscometer, and rotational viscometer are acceptable as analternative method.9.2 ASTM Ubbelohde (Suspended Level)-typeViscometerTo determine the viscosity
22、 of formic acid use anASTM Ubbelohde viscometer Size 1 with an inside diameter of0.58 mm 6 2 %. For use to determine the viscosity of thepolyamide solutions use the appropriate ASTM Ubbelohdeviscometer as defined in Specification D446, Fig. A2.1 for thepolyamide viscosity range.9.2.1 Apparatus:9.2.1
23、.1 Constant-Temperature Liquid Bath, set to operate at25 6 0.1C.9.2.1.2 Precision Thermometer, calibrated, for use in theliquid bath (ASTMS45C (non-mercury), and ASTM 45C(mercury-filled). (WarningMercury has been designated bymany regulatory agencies as a hazardous material that cancause serious med
24、ical issues. Mercury, or its vapor, has beendemonstrated to be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product SafetyData Sheet (SDS) for additional information. Users should beaware that selling
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7892018STANDARDTESTMETHODFORDETERMINATIONOFRELATIVEVISCOSITYOFCONCENTRATEDPOLYAMIDEPASOLUTIONSPDF

链接地址:http://www.mydoc123.com/p-512189.html