ASTM D395-2003(2008) Standard Test Methods for Rubber Property&8212 Compression Set《橡胶特性 压缩形变的标准试验方法》.pdf
《ASTM D395-2003(2008) Standard Test Methods for Rubber Property&8212 Compression Set《橡胶特性 压缩形变的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D395-2003(2008) Standard Test Methods for Rubber Property&8212 Compression Set《橡胶特性 压缩形变的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 395 03 (Reapproved 2008)Standard Test Methods forRubber PropertyCompression Set1This standard is issued under the fixed designation D 395; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the testing of rubber intende
3、dfor use in applications in which the rubber will be subjected tocompressive stresses in air or liquid media. They are applicableparticularly to the rubber used in machinery mountings, vibra-tion dampers, and seals. Two test methods are covered asfollows:Test Method SectionACompression Set Under Con
4、stant Force in Air 710BCompression Set Under Constant Deflection in Air 11141.2 The choice of test method is optional, but considerationshould be given to the nature of the service for whichcorrelation of test results may be sought. Unless otherwisestated in a detailed specification, Test Method B s
5、hall be used.1.3 Test Method B is not suitable for vulcanizates harderthan 90 IRHD.1.4 The values stated in SI units are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
6、 standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1349 Practice for RubberStandard Temperatures forTestingD 3182 Practice for RubberMaterials, Equipment, andProcedures f
7、or Mixing Standard Compounds and Prepar-ing Standard Vulcanized SheetsD 3183 Practice for RubberPreparation of Product Piecesfor Test Purposes from ProductsD 3767 Practice for RubberMeasurement of DimensionsD 4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Bl
8、ack ManufacturingIndustriesE 145 Specification for Gravity-Convection and Forced-Ventilation Ovens3. Summary of Test Methods3.1 A test specimen is compressed to either a deflection orby a specified force and maintained under this condition for aspecified time and at a specified temperature.3.2 The r
9、esidual deformation of a test specimen is measured30 min after removal from a suitable compression device inwhich the specimen had been subjected for a definite time tocompressive deformation under specified conditions.3.3 After the measurement of the residual deformation, thecompression set, as spe
10、cified in the appropriate test method, iscalculated according to Eq 1 and Eq 2.4. Significance and Use4.1 Compression set tests are intended to measure the abilityof rubber compounds to retain elastic properties after pro-longed action of compressive stresses. The actual stressingservice may involve
11、 the maintenance of a definite deflection,the constant application of a known force, or the rapidlyrepeated deformation and recovery resulting from intermittentcompressive forces. Though the latter dynamic stressing, likethe others, produces compression set, its effects as a whole aresimulated more
12、closely by compression flexing or hysteresistests. Therefore, compression set tests are considered to bemainly applicable to service conditions involving staticstresses. Tests are frequently conducted at elevated tempera-tures.5. Test Specimens5.1 Specimens from each sample may be tested in duplicat
13、e(Option 1) or triplicate (Option 2). The compression set of thesample in Option 1 shall be the average of the two specimensexpressed as a percentage. The compression set of the samplein Option 2 shall be the median (middle most value) of thethree specimens expressed as a percentage.5.2 The standard
14、 test specimen shall be a cylindrical diskcut from a laboratory prepared slab.1These test methods are under the jurisdiction of ASTM Committee D11 onRubber and are the direct responsibility of Subcommittee D11.10 on PhysicalTesting.Current edition approved May 1, 2008. Published June 2008. Originall
15、yapproved in 1934. Last previous edition approved in 2003 as D 395 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
16、 website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.1 The dimensions of the standard specimens shall be:Type 1A2BThickness, mm (in.) 12.5 6 0.5(0.49 6 0.02)6.0 6 0.2(0.24 6 0.01)Diameter, mm (in.) 29.0 6 0.5(1.14 6 0.02)13.0
17、 6 0.2(0.51 6 0.01)AType 1 specimen is used in Test Methods A and B.BType 2 specimen is used in Test Method B.5.2.2 When cutting the standard specimen, the circular diehaving the required inside dimensions specified in 5.2.1 shallbe rotated in a drill press or similar device and lubricated bymeans o
18、f a soap solution. A minimum distance of 13 mm (0.51in.) shall be maintained between the cutting edge of the die andthe edge of the slab. The cutting pressure shall be as light aspossible to minimize cupping of the cut edges. The dies shallbe maintained carefully so that the cutting edges are sharp
19、andfree of nicks.5.3 An optional method of preparing the standard specimenmay be the direct molding of a circular disk having thedimensions required for the test method used and specified in5.2.1.NOTE 1It should be recognized that an equal time and temperature, ifused for both the slab and molded sp
20、ecimen, will not produce anequivalent state of cure in the two types of specimen. A higher degree ofcure will be obtained in the molded specimen. Adjustments, preferably inthe time of cure, must be taken into consideration if comparisons betweenthe specimens prepared by different methods are to be c
21、onsidered valid.NOTE 2It is suggested, for the purpose of uniformity and closertolerances in the molded specimen, that the dimensions of the mold bespecified and shrinkage compensated for therein. A two-plate mold with acavity 13.0 6 0.1 mm (0.510 6 0.004 in.) in thickness and 29.20 6 0.05mm (1.148
22、6 0.002 in.) in diameter, with overflow grooves, will provideType 1 specimens for Test Method A and Test Method B. A similar moldbut having a cavity of 6.3 6 0.3 mm (0.25 6 0.012 in.) in thickness and13.2 6 0.1 mm (0.52 6 0.004 in.) in diameter will provide Type 2specimens for Test Method B.5.4 When
23、 the standard test specimen is to be replaced by aspecimen taken from a vulcanized rubber part of greaterthickness than the one indicated in 5.2.1, the sample thicknessshall be reduced first by cutting transversely with a sharp knifeand then followed by buffing to the required thickness inaccordance
24、 with Practice D 3183.5.5 An alternative method of preparing specimens is byplying up cylindrical disks cut from a standard sheet preparedin accordance with Practice D 3182 using the specimen sizesspecified in 5.2.1 and cutting as described in 5.2.2, or where adrill press is not available cutting th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39520032008STANDARDTESTMETHODSFORRUBBERPROPERTY8212COMPRESSIONSET 橡胶 特性 压缩 形变 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511622.html