ASTM D2084-2007 Standard Test Method for Rubber Property-Vulcanization Using Oscillating Disk Cure Meter《用振动圆盘硫化计测定橡胶硫化性能的标准试验方法》.pdf
《ASTM D2084-2007 Standard Test Method for Rubber Property-Vulcanization Using Oscillating Disk Cure Meter《用振动圆盘硫化计测定橡胶硫化性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2084-2007 Standard Test Method for Rubber Property-Vulcanization Using Oscillating Disk Cure Meter《用振动圆盘硫化计测定橡胶硫化性能的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2084 07Standard Test Method forRubber PropertyVulcanization Using Oscillating Disk CureMeter1This standard is issued under the fixed designation D 2084; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the use of the
3、oscillating diskcure meter for determining selected vulcanization characteris-tics of vulcanizable rubber compounds.1.2 ISO 3417 is very similar to this test method. It has minortechnical differences that are not considered to be significant.1.3 The values stated in SI units are to be regarded as th
4、estandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the ap
5、plica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1349 Practice for RubberStandard Temperatures forTestingD 3185 Test Methods for RubberEvaluation of SBR(Styrene-Butadiene Rubber) Including Mixtures With OilD 3186 Test Methods for RubberEvaluation of SB
6、R(Styrene-Butadiene Rubber) Mixed With Carbon Black orCarbon Black and OilD 3187 Test Methods for RubberEvaluation of NBR(Acrylonitrile-Butadiene Rubber)D 3190 Test Method for RubberEvaluation of Chloro-prene Rubber (CR)D 4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber
7、and Carbon Black ManufacturingIndustries2.2 ISO Standard:ISO 3417 RubberMeasurement of Vulcanization Charac-teristics With the Oscillating Disk Rheometer33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 The following measurements may be taken from thetorque versus time curve (s
8、ee Fig. 1).3.1.2 cure rate indexmeasure of rate of vulcanizationbased on the difference between optimum vulcanization andincipient scorch time.3.1.3 peak cure ratemeasure of rate of vulcanizationexpressed as the maximum slope of the torque versus timecurve.3.1.4 maximum, plateau, or highest torqueme
9、asure ofstiffness or shear modulus of the fully vulcanized test specimenat the vulcanization temperature.3.1.5 minimum torquemeasure of the stiffness of theunvulcanized test specimen taken at the lowest point of thecurve.3.1.6 time to incipient cure (scorch time)measure of thetime at which vulcaniza
10、tion begins.3.1.7 time to a percentage of full curemeasure of curebased on the time to develop some percentage of the highesttorque or difference in torque from the minimum.3.1.8 torquefor an oscillating shear cure meter, the valuemeasured by a torque transducer at the peak strain amplitude ofthe os
11、cillating cycle.3.1.9 optimum cure timemeasure of the time required toreach a percentage of full cure that corresponds to a desiredlevel of a property of the cured compound.3.1.9.1 DiscussionThe time to reach 90 % cure corre-sponds to a maximum in tensile strength for some rubbercompounds. This does
12、 not apply in all cases.4. Summary of Test Method4.1 A test specimen of vulcanizable rubber compound isinserted into the cure meter test cavity and after a closureaction is contained in a sealed cavity under positive pressure.The cavity is maintained at some elevated vulcanization1This test method i
13、s under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.12 on Processability Tests.Current edition approved July 1, 2007. Published July 2007. Originally approvedin 1971. Last previous edition approved in 2006 as D 2084 06.2For referenced ASTM sta
14、ndards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute, 25 W. 43rd St., 4thFloor, New
15、York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.temperature. The rubber totally surrounds a biconical disk afterthe dies are closed (see Fig. 2). The disk is oscillated througha small rotational amplitude (1 or 3) and
16、this action exerts ashear strain on the test specimen.The force required to oscillateor rotate the disk to maximum amplitude is continuouslyrecorded as a function of time, with the force being propor-tional to the shear modulus (stiffness) of the test specimen atthe test temperature. This stiffness
17、initially decreases as itwarms up; then it increases due to vulcanization. The test iscompleted when the recorded torque either rises to an equilib-rium or maximum value, or when a predetermined time haselapsed. The time required to obtain a cure curve is a functionof the characteristics of the rubb
18、er compound and of the testtemperature (see Fig. 1 for typical cure curves).4.2 Several configurations of the oscillating disk cure meterare currently in use. Fig. 3 illustrates example shifts of the curecurves associated with the configuration differences included inthis standard. Results between t
19、ests using rapid and slowtemperature recovery, or between heated and unheated diskscannot be compared without taking the heating differences intoaccount. The differences between test curves will vary with theLeft Curve: Cure to Equilibrium Torque.Middle Curve: Cure to a Maximum Torque with Reversion
20、.Right Curve: Cure to No Equilibrium in Maximum Torque.FIG. 1 Types of Cure CurveFIG. 2 Cure Meter AssemblyFIG. 3 Example Cure Curves from ODR ConfigurationsD2084072compound being tested. Configurations included in this testmethod are listed in this section.4.2.1 Diaphragm dies, unheated rotor, temp
21、erature recoverywithin 4.5 min.4.2.2 Solid dies, unheated rotor, temperature recoverywithin 4.5 min.4.2.3 Solid dies, unheated rotor, temperature recovery inless than 2 min.4.2.4 Solid dies, heated rotor, temperature recovery in lessthan 2 min.NOTE 1Diaphragm dies are unique to cure meters developed
22、 beforerapid temperature recovery and heated rotors were introduced. Diaphragmdies in combination with rapid temperature recovery or heated rotors arenot a normal configuration for Oscillating Disk Cure Meters.5. Significance and Use5.1 This test method is used to determine the vulcanizationcharacte
23、ristics of (vulcanizable) rubber compounds.5.2 This test method may be used for quality control inrubber manufacturing processes, for research and developmenttesting of raw-rubber compounded in an evaluation formula-tion, and for evaluating various raw materials used in preparing(vulcanizable) rubbe
24、r compounds.6. Apparatus6.1 Cure meter, consists of the following major compo-nents: specimen chamber and closure mechanism, temperaturecontrol system, rotor drive and torque measuring system (seeFig. 2 for a detailed drawing of cure meter assembly).6.2 Specimen ChamberConsists of platens, dies, and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD20842007STANDARDTESTMETHODFORRUBBERPROPERTYVULCANIZATIONUSINGOSCILLATINGDISKCUREMETER 振动 圆盘 硫化 测定

链接地址:http://www.mydoc123.com/p-510961.html