ASTM D1343-1995(2006) Standard Test Method for Viscosity of Cellulose Derivatives by Ball-Drop Method《用落球法测定纤维素衍生物粘度的标准试验方法》.pdf
《ASTM D1343-1995(2006) Standard Test Method for Viscosity of Cellulose Derivatives by Ball-Drop Method《用落球法测定纤维素衍生物粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1343-1995(2006) Standard Test Method for Viscosity of Cellulose Derivatives by Ball-Drop Method《用落球法测定纤维素衍生物粘度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1343 95 (Reapproved 2006)Standard Test Method forViscosity of Cellulose Derivatives by Ball-Drop Method1This standard is issued under the fixed designation D 1343; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method describes t
3、he apparatus and generalprocedure for making ball-drop viscosity measurements onsolutions of various cellulose derivatives. Instructions forsample preparation, solution concentration, and other detailsare discussed in theASTM methods for the respective cellulosederivatives.1.2 This test method is ap
4、plicable to solutions of variouscellulose derivatives having viscosities greater than 10 P, byusing balls of various diameters and densities. Viscosity resultsare expressed preferably in poises.1.3 In commercial practice, viscosities are often expressedin seconds using 2.38mm (332-in.) stainless ste
5、el balls.2Whenthe viscosity is outside the practical range for these balls (75 to300 P), the measurement can be made using a calibrated pipetviscometer or a different ball and calculating the observedviscosity to the corresponding time for a 2.38-mm (332-in.)ball, even though it is a small fraction
6、of a second.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to e
7、stablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 301 Test Methods for Soluble Cellulose NitrateD 445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and the Cal
8、culation of DynamicViscosity)D 817 Test Methods of Testing Cellulose Acetate Propi-onate and Cellulose Acetate ButyrateD 871 Test Methods of Testing Cellulose AcetateE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Summary of Test Method3.1 A soluti
9、on of the cellulose derivative is made in asuitable solvent and allowed to equilibrate at a chosen tem-perature. A stainless steel or aluminum ball is dropped into thesolution, and the time required for it to cover a measureddistance in its fall is recorded. The viscosity of the solution canthen be
10、calculated in poise or recorded in seconds.NOTE 1The choice of solvent has significant influence on viscosity.4. Significance and Use4.1 This test provides an easy method of determining theviscosity of cellulose derivatives in a given solvent. Theanswers are in units commonly used in industrial prac
11、tice.Such information is needed for cellulose derivatives that are tobe extruded, molded, sprayed, or brushed as is or in solution.5. Apparatus5.1 Constant-Temperature Water Bath, glass-walled.5.1.1 For routine testing, an aquarium viscometer is recom-mended. This viscometer is a rectangular glass e
12、nclosure withfront and rear walls that have etched horizontal parallel lines50.8 mm (2.00 6 0.02 in.) apart. The bottles containing thesamples solutions are set inside the viscometer at a level suchthat the upper etched line of the viscometer is at least 12.7 mm(12 in.) below the upper surface of th
13、e solution in the bottle,and the lower etched line of the viscometer is at least 12.7 mm(12 in.) above the bottom of the sample bottle. Suitable lightingis provided to enable the observer to sight across the paralleletched lines, through the sample bottle and solution, avoidingin this manner paralla
14、x errors. With this viscometer no timingmarkers need to be provided on the bottles.5.2 Bottles and Caps:1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.36 on Cellulose and
15、Cellulose Derivatives.Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 1954. Last previous edition approved in 2000 as D 1343 95 (2000).2When a332-in. stainless steel ball is used, the viscosities in seconds should bepractically the same as those obtained using the
16、 apparatus described in Section 11of Test Methods D 871 48, and in Section 10 of Test Methods D 301 50, whichlast appeared in the 1952 Annual Book of ASTM Standards, Part 4.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For A
17、nnual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.1 Bottles, round or square, conforming to the dimen-sional requiremen
18、ts shown in Table 1, shall be used. Screwcaps of metal or phenolic plastic in sizes to fit the bottles andhaving aluminum foil or cardboard and cellophane liners maybe used to close the bottles. Alternatively, rubber stopperscovered with aluminum or tin foil, may also be used asclosures. In this lat
19、ter case, solvent loss during measurement ofviscosity can be minimized by removing the stopper, leavingthe foil in place, and making a small hole in the center of thefoil through which the balls may be dropped.5.2.2 Timing marks shall be provided around each bottle oron the front and back of the gla
20、ss-walled constant-temperaturewater bath, to avoid parallax errors. The lower timing markshall be at least 13 mm (0.5 in.) above the base of the bottle,and the upper mark shall be 50.8 6 0.5 mm (2.00 6 0.02 in.)above the lower mark.Apractical means of marking consists ofwrapping a 50.8 mm (2-in.) st
21、rip of transparent sheeting aroundthe water bath at the proper location. The edges of the sheetingmay be darkened with crayon.Alight located back of the waterbath aids in observing the ball during its fall.5.3 BallsUnless specifically directed otherwise, balls ofvarying size and density shall be use
22、d, depending on theviscosity of the solution. Table 2 gives the useful ranges,approximate apparatus constants, and dimensions of severalsuch balls. The exact diameter, weight, and density shall bedetermined accurately for each lot of balls used.5.4 Stop WatchA stop watch reading to 0.2 s.6. Calibrat
23、ion6.1 Calculate the apparatus constant, K, using the followingequation and exact dimensions of the bottle and balls used:K 5 2gr21 2 2.104d/D! 1 2.09d/D!3#/9Lwhere:g = acceleration of gravity in cgs unitsr = ball radius, cm,d = ball diameter, cm,D = bottle diameter, cm (in the case of square bottle
24、s theaverage of the side to side and corner to cornerdiameters shall be used), andL = distance of ball drop, cm.7. Procedure7.1 Preparation of SolutionDry the sample and prepare asolution as specified for the particular material. Such instruc-tions are given in the viscosity sections of Test Methods
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD134319952006STANDARDTESTMETHODFORVISCOSITYOFCELLULOSEDERIVATIVESBYBALLDROPMETHOD 用落球法 测定 纤维素 衍生物

链接地址:http://www.mydoc123.com/p-509672.html