ASTM C836 C836M-2015 Standard Specification for High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course《与独立磨耗层共同使用的高固体含量 应用冷.pdf
《ASTM C836 C836M-2015 Standard Specification for High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course《与独立磨耗层共同使用的高固体含量 应用冷.pdf》由会员分享,可在线阅读,更多相关《ASTM C836 C836M-2015 Standard Specification for High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course《与独立磨耗层共同使用的高固体含量 应用冷.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C836/C836M 15Standard Specification forHigh Solids Content, Cold Liquid-Applied ElastomericWaterproofing Membrane for Use with Separate WearingCourse1This standard is issued under the fixed designation C836/C836M; the number immediately following the designation indicates the yearof ori
2、ginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification describes the required properties andtest m
3、ethods for a cold liquid-applied elastomeric-typemembrane, one- or two-component, for waterproofing buildingdecks and walls subject to hydrostatic pressure in buildingareas to be occupied by personnel, vehicles, or equipment. Thisspecification applies only to a membrane system that will becovered wi
4、th a separate wearing course, traffic course, orbackfill.NOTE 1See Guide C898 and Guide C1471 for proper application ofmembrane.1.2 There are no ISO standards similar or equivalent to thisASTM standard.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as stand
5、ard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, asso
6、ciated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C794 Test Method forAdhesion-in-Peel of Elastomeric Joint
7、SealantsC898 Guide for Use of High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane with Sepa-rate Wearing CourseC1305 Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing MembraneC1375 Guide for Substrates Used in Testing Building Sealsand SealantsC1471 Guide
8、 for the Use of High Solids Content ColdLiquid-Applied Elastomeric Waterproofing Membrane onVertical SurfacesC1522 Test Method for Extensibility After Heat Aging ofCold Liquid-Applied Elastomeric Waterproofing Mem-branesD1079 Terminology Relating to Roofing and WaterproofingD2240 Test Method for Rub
9、ber PropertyDurometer Hard-nessD6511 Test Methods for Solvent Bearing Bituminous Com-pounds3. Terminology3.1 DefinitionsRefer to Terminology D1079 for defini-tions of the terms used in this specification.4. Classification4.1 Types:4.1.1 Type IA one-component, cold liquid-applied water-proofing mater
10、ial suitable for immediate application aftermixing. Type I products may be used with an accelerator thatis beneficial but not essential for curing of the membrane.4.1.2 Type IIA two-component, cold liquid-applied water-proofing material. Combining two components is essential forcuring of the membran
11、e.5. Physical Requirements5.1 MaterialMembrane materials shall cure, after appli-cation by spreading or spraying, to form an elastomeric filmcapable of maintaining a seal against liquid water.5.2 The physical, mechanical, and performance propertiesof the membrane shall conform to the requirements de
12、scribedin Table 1.1This specification is under the jurisdiction of ASTM Committee D08 onRoofing and Waterproofing and is the direct responsibility of Subcommittee D08.22on Waterproofing and Dampproofing Systems.Current edition approved June 1, 2015. Published June 2015. Originallyapproved in 1976. L
13、ast previous edition approved in 2012 as C836/C836M 12.DOI: 10.1520/C0836_C0836M-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary p
14、age onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Test Methods6.1 Standard ConditionsStandard conditions for all testsshall be 23 6 2C 73.4 6 3.6F and 50 6 5 % relativehumidity.6.2 Conditioning/Mixing:6.2.1 Sto
15、re all membrane materials to be tested in anunopened container at standard conditions for at least 24 hbefore any test specimens are prepared.6.2.2 Follow the manufacturers instructions for mixing andpreparing membrane materials for testing. Thoroughly mixone-component samples before using. Mix two-
16、componentcompounds in the ratio recommended by the manufacturer.6.3 Test SurfacesIn addition to the mortar test surfacesspecified, use other test surfaces when required by the specifier.6.4 PrimerWhen required by the manufacturer, use aprimer as directed by the manufacturer on all substrate mate-ria
17、ls in test assemblies.6.5 Hardness:6.5.1 Following the manufacturers instructions, apply afilm of membrane, 1.5 6 0.1 mm 60 6 5 mils thick, on a 100by 150-mm 4 by 6-in. piece of polyethylene film-coatedpaper and allow the membrane to cure for 14 days at standardconditions. If more than one applicati
18、on is required, the totaltime for film application shall not exceed 48 h.6.5.2 After curing, strip the film from the coated paper, cutinto pieces, and lay the pieces one upon another to provide atest specimen meeting the requirements of Test Method D2240.6.5.3 Using a Type 00 hardness gauge, obtain
19、an instanta-neous reading of the film hardness as specified in Test MethodD2240.6.6 Weight Loss:6.6.1 Test in compliance with the requirements of TestMethod D6511, Section 7; utilize a forced draft oven controlledto 70 6 2C 158 6 3.6F for 72 hours. Remove thespecimens from the oven and allow to cool
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC836C836M2015STANDARDSPECIFICATIONFORHIGHSOLIDSCONTENTCOLDLIQUIDAPPLIEDELASTOMERICWATERPROOFINGMEMBRANEFORUSEWITHSEPARATEWEARINGCOURSE

链接地址:http://www.mydoc123.com/p-508486.html