ASTM C400-1998(2006) Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid《中和废酸用生石灰和熟石灰的标准试验方法》.pdf
《ASTM C400-1998(2006) Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid《中和废酸用生石灰和熟石灰的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C400-1998(2006) Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid《中和废酸用生石灰和熟石灰的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 400 98 (Reapproved 2006)Standard Test Methods forQuicklime and Hydrated Lime for Neutralization of WasteAcid1This standard is issued under the fixed designation C 400; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the testing of quicklime andhydrated lime for use in the treatment of waste acid
3、solutionsand includes the characterization of the liming material and ofthe acid waste.NOTE 1When agreed upon by the manufacturer and the purchaser,this method may be used directly to evaluate the lime requirement for aplant waste acid and in the preparation of the lime slurry; the pH, the time,temp
4、erature, and other conditions of treatment may be adjusted toconform to plant practice. Otherwise the test shall be performed asdescribed in this method.NOTE 2Under some conditions of test the lime requirement may varysubstantially from that indicated by ultimate chemical analysis or by theuse of a
5、determination of available alkalinity by titration to a stoichio-metric end point.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and d
6、etermine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C50 Practice for Sampling, Sample Preparation, Packag-ing, and Marking of Lime and Limestone ProductsE70 Test Method for pH of Aqueous Solutions With theGlass Electrode3. Terminology3.1 Defi
7、nitions:3.1.1 neutralization coeffcientthe number of parts of limerequired to neutralize one million parts by weight of sulfuricacid solution (1.5 %) to a pH of 4.4 in 30 min (see Note 1).3.1.2 pHa measure of the hydrogen ion concentration of asample and representing the logarithm of the reciprocal
8、(nega-tive logarithm) of the activity of hydrogen ions, calculated asfollows:pH5log1H!152logH1!where:H+= activity of hydrogen ions.4. Significance and Use4.1 Since all limes and waste acid solutions are different,this test method evaluates the relative quantity of a given limeneeded for the neutrali
9、zation of a specific quantity of acid.4.2 Liming materials have a specific basicity factor ormeasure of alkalinity which can be used for comparing theirrelative neutralizing power. It avoids dependence on chemicalanalysis and is determined as grams of calcium oxide equiva-lents per kilogram of limin
10、g material.4.3 Likewise, specific waste acids have an acid value thatcan be expressed as grams of hydrochloric acid equivalent perlitre of acid waste. This value is related on a stoichiometricbasis to lime neutralization requirements of a liquid acid waste.5. Apparatus5.1 pH Measuring Apparatus, con
11、forming to the require-ments of Section 5, Apparatus, and Section 6, Reagents andMaterials, of Test Method E70. A time-pH recording device orattachment is desirable but not required.5.2 Analytical Balance, capable of reproducing resultswithin 0.005 g.5.3 Stirrer, motorized, capable of rotating at sp
12、eeds from120 to 600 r/min.5.4 Miscellaneous EquipmentChemically resistant glass-ware,3metal stands for support of the equipment, etc.6. Purity of Reagents6.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shall1These test methods are u
13、nder the jurisdiction of ASTM Committee C07 onLime and are the direct responsibility of Subcommittee C07.05 on Chemical Tests.Current edition approved June 1, 2006. Published July 2006. Originally approvedin 1957. Last previous edition approved in 1998 as C 400 98.2For referenced ASTM standards, vis
14、it the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Borosilicate glass has been found satisfactory for this purpose.1Copyright ASTM International,
15、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.conform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.4Other grades may be used, pro-vided it is first ascertained that the reag
16、ent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Unless otherwise indicated, references to water shall beunderstood to mean distilled water.7. Test Method Afor Determining Lime Requirement forthe neutralization of a standard sulfuric acid or
17、waste acidsolution within a time limit of thirty minutes.7.1 Reagents:7.1.1 Sulfuric Acid, Standard Solution (1.5 6 0.05 %)Thoroughly mix 15.8 g of concentrated sulfuric acid (95 %H2SO4) with water, dilute to 1 L, analyze to within 0.005 %H2SO4, and store in a suitable stoppered bottle.7.2 Preparati
18、on of Sample:7.2.1 Take samples of quicklime and hydrated lime inaccordance with Methods C50.7.2.2 QuicklimeWeigh a sample of quicklime (2.50 60.01 g) ground to pass a No. 50 mesh sieve. Add to a 500-mLtall-form beaker containing 50 mL of boiling water andcontinue to boil for 2 min. Remove from hot
19、plate and continuestirring with a magnetic stirrer until the slurry reaches roomtemperature (at least 10 min).7.2.3 Hydrated LimeMix a sample of hydrated lime (2.506 0.01 g) with 50 mL of water in a 500-mL tall-form beakerfor at least 10 min.7.3 Procedure:7.3.1 Place the pH electrodes within the bea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC40019982006STANDARDTESTMETHODSFORQUICKLIMEANDHYDRATEDLIMEFORNEUTRALIZATIONOFWASTEACID 中和 废酸用 生石灰

链接地址:http://www.mydoc123.com/p-466485.html