1、Designation: C222 97 (Reapproved 2014)Standard Specification forAsbestos-Cement Roofing Shingles1This standard is issued under the fixed designation C222; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers asbestos-cement roofingshingles, including accessories, designed to provide theweather-exposed surfaces on r
3、oofs of buildings.1.2 Shingles supplied under this specification are of thefollowing types as to shape and method of application:1.2.1 American MethodUniform thickness, generally rect-angular in shape, with straight or irregular edges. They areintended to be laid with a minimum 2-in. (51-mm) head la
4、p andwith no side lap and to provide double coverage. They may bemade either as individual or multiple units to simulate theappearance of individual shingles.1.2.2 Strip ShinglesUniform thickness, various shapesand designs to provide top lap only and shingle coverage underthe butt joints, with the d
5、esign such that it provides only singlecoverage.1.2.3 Strip ShinglesUniform thickness, various shapesand designs to provide top lap only and shingle coverage underthe butt joints, with the design such that it provides only singlecoverage.1.2.4 Dutch or Scotch Method (Including Ranch Design)Uniform t
6、hickness with straight or irregular edges and de-signed to be laid with a lap at the top and on one side of eachshingle.1.2.4.1 DutchSquare in shape.1.2.4.2 RanchOblong-rectangular in shape, with thegreater dimension horizontal.1.2.5 French or Hexagonal MethodUniform thickness,square in shape, havin
7、g at least three corners clipped to givethe desired pattern when the shingles are laid with theirdiagonals perpendicular to the eave of the roof, with their apexsides lapped.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconve
8、rsions to SI units that are provided for information onlyand are not considered standard.1.4 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when
9、working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysotile asbestos, refer to “Safe Use ofChrysotile: A Manual on Preventive and Control Measures.”22. Referenced Documents2.1 ASTM Standards:3C459 Test Methods for Asbestos-Cement Flat Product
10、s2.2 Federal Standard:4Fed. Std. No. 123 Marking for Domestic Shipment (CivilianAgencies)2.3 Military Standard:4MIL-STD-129 Marking for Shipment and Storage2.4 Other Documents:Uniform Freight Classification Rule5National Motor Freight Classification Rules63. Materials and Manufacture3.1 Asbestos-cem
11、ent roofing shingles shall be composed ofa combination of asbestos fiber and portland cement orportland blast-furnace slag cement, and not more than 1 weight% of organic fiber, with or without the addition of curingagents, water-repellent substances, mineral fillers, coatings,pigments, or mineral gr
12、anules, formed under pressure andcured to meet the physical requirements of this specification.4. Physical Requirements4.1 All measurements and tests necessary for determiningthe conformity of the asbestos-cement shingles with thisspecification shall be made in accordance with Methods C459.1This spe
13、cification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of SubcommitteeC17.03 on Asbestos - Cement Sheet Products and Accessories.Current edition approved Dec. 1, 2014. Published December 2014. Originallyapproved in 1949. Last pr
14、evious edition approved in 2008 as C222 97 (2008).DOI: 10.1520/C0222-97R14.2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
15、 the standards Document Summary page onthe ASTM website.4Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.5Available from the Uniform Classification Commission Room 1106, 222 S.Riverside Plaza, Ch
16、icago, IL. 60606.6Available from National Motor Freight Inc., 1616 P. St., N. W., Washington, DC20036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Flexural StrengthThe average breaking load obtainedby loading equally and simult
17、aneously at both one-third pointsof the test span.4.3 DeflectionThe average deflection at mid-span at maxi-mum load obtained by loading equally and simultaneously atboth one-third points of the test span.4.4 Water AbsorptionThe average water absorption shallnot exceed 25 weight %.5. Dimensions, Mass
18、, and Permissible Variations5.1 Shingles supplied under this specification shall conformto the dimensions prescribed in Table 1. Units of one halfnormal width shall be supplied in an amount not exceeding twoper bundle.5.2 ThicknessThe average thickness of all units suppliedunder these specifications
19、 shall be as shown in Table 2, and theaverage thickness of any one unit shall not vary from theaverage of all units within the shipment by more than 10 %.For textured shingles, this thickness shall be construed as thegross overall measurement from the top of the textured surfaceto the back of the un
20、it.5.3 Width and LengthThe permissible variation from thenominal width or length shall be 618 in. (63.18 mm), asmeasured after 48 h at 73F (23C) and 50 % relative humidity.6. Workmanship, Finish, and Appearance6.1 WorkmanshipThe surface of the shingles to be ex-posed shall be free of defects that im
21、pair appearance orserviceability.6.2 FinishThe surface of the shingles to be exposed shallbe smooth, grained, granuled, coated, or otherwise textured.6.3 ColorThe exposed surface of the shingles shall benatural color of the asbestos-cement product or shall be coloredby the addition of mineral pigmen
22、ts, chemical impregnation,pigmented coatings, veneers, or embedded mineral granules.6.4 Holes for Nails and FastenersHoles for nails andfasteners shall be provided in the units during manufacture andshall be so placed as to provide at least the minimum lap asspecified in Table 1 and to allow for pro
23、per application ofnecessary clips or storm fasteners.6.5 EfflorescenceEfflorescence that sometimes appears onasbestos-cement shingles is not a defect and shall not result ina permanent change in color.7. Supplementary Shapes7.1 StartersStarter pieces, for application at the eaves, areavailable for e
24、ach type of shingle and shall have the samegeneral characteristics as the shingles.7.2 Hip and Ridge Finishing PiecesFinishing pieces, forapplication on hips and ridges, are available for each type ofshingle and shall have the same general characteristics as theshingles.7.3 Ridge RollCurved or angul
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC22219972014STANDARDSPECIFICATIONFORASBESTOSCEMENTROOFINGSHINGLES 石棉 水泥 屋面板 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466063.html