《ASTM C1433-2007a Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers《涵洞、暴雨排水管和下水道用的预制钢筋混凝土箱型部件用标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1433-2007a Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers《涵洞、暴雨排水管和下水道用的预制钢筋混凝土箱型部件用标准规范》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1433 07aStandard Specification forPrecast Reinforced Concrete Monolithic Box Sections forCulverts, Storm Drains, and Sewers1This standard is issued under the fixed designation C 1433; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers single-cell precast reinforcedconcrete box sections cast monoli
3、thically and intended to beused for the construction of culverts and for the conveyance ofstorm water industrial wastes and sewage.1.2 This specification is the companion to SI SpecificationC 1433M; therefore, no SI equivalents are shown in thisspecification.NOTE 1This specification is primarily a m
4、anufacturing and purchas-ing specification. However, standard designs are included and the criteriaused to develop these designs are given in Appendix X1. The successfulperformance of this product depends upon the proper selection of the boxsection, bedding, backfill, and care that the installation
5、conforms to theconstruction specifications. The purchaser of the precast reinforcedconcrete box sections specified herein is cautioned that proper correlationof the loading conditions and the field requirements with the box sectionspecified, and provision for inspection at the construction site, are
6、required.2. Referenced Documents2.1 ASTM Standards:2A 82/A 82M Specification for Steel Wire, Plain, for Con-crete ReinforcementA 185/A 185M Specification for Steel Welded Wire Rein-forcement, Plain, for ConcreteA 496/A 496M Specification for Steel Wire, Deformed, forConcrete ReinforcementA 497/A 497
7、M Specification for Steel Welded Wire Rein-forcement, Deformed, for ConcreteA 615/A 615M Specification for Deformed and PlainCarbon-Steel Bars for Concrete ReinforcementC 31/C 31M Practice for Making and Curing Concrete TestSpecimens in the FieldC33 Specification for Concrete AggregatesC 39/C 39M Te
8、st Method for Compressive Strength of Cy-lindrical Concrete SpecimensC 150 Specification for Portland CementC 309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC 497 Test Methods for Concrete Pipe, Manhole Sections,or TileC 595 Specification for Blended Hydraulic CementsC 6
9、18 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC 822 Terminology Relating to Concrete Pipe and RelatedProductsC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1116 Specification for Fiber-Reinforced Concrete andSho
10、tcrete2.2 AASHTO Standard:3Standard Specifications for Highway Bridges3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C 822.4. Types4.1 Precast reinforced concrete box sections manufacturedin accordance with this specification shall be one of two typ
11、esidentified in Table 1 and Table 2, and shall be designated bytype, span, rise, and design earth cover.5. Basis of Acceptance5.1 Acceptability of the box sections produced in accor-dance with Section 7 shall be determined by the results of theconcrete compressive strength tests described in Section
12、 10,bythe material requirements described in Section 6, and byinspection of the finished box sections.5.2 Box sections shall be considered ready for acceptancewhen they conform to the requirements of this specification.6. Material6.1 Reinforced ConcreteThe reinforced concrete shallconsist of cementi
13、tious materials, mineral aggregates and1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.07 onAcceptance Specifications and Precast Concrete Box Sections.Current edition approved Sept. 1, 2007. Published October 2
14、007. Originallyapproved in 1999. Last previous edition approved in 2007 as C 1433 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
15、page onthe ASTM website.3Available from American Association of State Highway and TransportationOfficials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.water, in whi
16、ch steel has been embedded in such a manner thatthe steel and concrete act together.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsfor portland cement of Specification C 150 or shall be portlandblast-furnace slag cement or portland-pozzolan cement con-forming to the r
17、equirements of Specification C 595, except thatthe pozzolan constituent in the Type IP portland-pozzolancement shall be fly ash.6.2.2 Fly AshFly ash shall conform to the requirements ofSpecification C 618, Class F or Class C.6.2.3 Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to th
18、e requirements of Grade 100 or 120of Specification C 989.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified po
19、rtland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and fly ash.6.2.4.6 A combination of portland cement and groundgranulated blast-furnace slag,6.2.4.7 A combination of portland cement, ground granu-lated blast-furnace slag (not to exceed 25 % of the to
20、talcementitious weight), and fly ash (not to exceed 25 % of thetotal cementitious weight).6.3 AggregatesAggregates shall conform to SpecificationC33, except that the requirements for gradation shall notapply.6.4 Admixtures and BlendsAdmixtures and blends shallbe allowed to be used with the approval
21、of the purchaser.6.5 Steel ReinforcementReinforcement shall consist ofwelded wire reinforcement conforming to SpecificationsA 185/A 185M or A 497/A 497M. Circumferential reinforce-ment areas in Tables 1 and 2 are based solely on the use ofwelded wire reinforcement, refer to 11.6 if alternate steelde
22、signs utilizing steel bars, Grade 60, in conjunction with or inlieu of welded wire reinforcement are to be submitted for theowners approval. Longitudinal distribution reinforcementshall be allowed to consist of welded wire reinforcement ordeformed billet-steel bars conforming to Specification A 615/
23、A 615M, Grade 60.6.6 Synthetic FibersThe manufacturer is not prohibitedfrom using collated fibrillated virgin polypropylene fibers inprecast box culverts as a nonstructural manufacturing material.Only Type III synthetic fibers designed and manufacturedspecifically for use in concrete and conforming
24、to the require-ments of Specification C 1116 shall be accepted.7. Design7.1 Design TablesThe box section dimensions, compres-sive strength of the concrete, and reinforcement details shall beas prescribed in Table 1 or Table 2 and Figs. 1-4, subject to theprovisions of Section 11. Table 1 sections ar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC14332007ASTANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETEMONOLITHICBOXSECTIONSFORCULVERTSSTORMDRAINSANDSEWERS

链接地址:http://www.mydoc123.com/p-464637.html