ASTM C1282-2000(2006) Standard Test Method for Determining the Particle Size Distribution of Advanced Ceramics by Centrifugal Photosedimentation《用离心光电沉淀法测定高级陶瓷粒径分布的标准试验方法》.pdf
《ASTM C1282-2000(2006) Standard Test Method for Determining the Particle Size Distribution of Advanced Ceramics by Centrifugal Photosedimentation《用离心光电沉淀法测定高级陶瓷粒径分布的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1282-2000(2006) Standard Test Method for Determining the Particle Size Distribution of Advanced Ceramics by Centrifugal Photosedimentation《用离心光电沉淀法测定高级陶瓷粒径分布的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1282 00 (Reapproved 2006)Standard Test Method forDetermining the Particle Size Distribution of AdvancedCeramics by Centrifugal Photosedimentation1This standard is issued under the fixed designation C 1282; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determination of the particlesize distribut
3、ion of advanced ceramic powders specificallysilicon nitride and carbides, in the range of 0.1 to 20 m,having a median particle diameter from 0.5 to 5.0 m.1.2 The procedure described in this test method may beapplied successfully to other ceramic powders in this generalsize range, provided that appro
4、priate dispersion procedures aredeveloped. It is the responsibility of the user to determine theapplicability of this test method to other materials.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not
5、 purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards
6、:2C 242 Terminology of Ceramic Whitewares and RelatedProducts3. Terminology3.1 DefinitionsRefer to Terminology C 242 for definitionsof terms used in this test method.4. Summary of Test Method4.1 A homogeneous aqueous dispersion of the powder isprepared. While kept in a thoroughly mixed condition, a
7、smallaliquot is transferred to the analyzer sample cell, which isplaced in the instrument and subjected to a controlled centrifu-gal acceleration at a known or controlled temperature. Atpredetermined times related to the sedimentation of specificStokes diameters (Note 1), the optical absorbance is r
8、ecordedand compared to the initial value to determine the fraction ofthe total sample that has sedimented a specific distance. Avolume-based size distribution is calculated from theabsorbance-time data. The results are reported as equivalentdiameter (spherical) (Note 2) since particles in these powd
9、ersare not truly spherical.NOTE 1This diameter in m is referred to as D in the equation givenbelow.NOTE 2Refer to Terminology C 242 for the ASTM definition of thisterm. Most equipment manufacturers refer to this as the equivalentspherical diameter.D2518h logX1X2ps pf!u2t3 108(1)where:h = viscosity o
10、f the fluid, cP,X1= distance from the middle of the centrifugal disc cell to the pointin the cell where sedimentation starts,X2= distance from the center of the centrifugal disc cell to the pointwhere the light beam intersects the particlet = time for the particle to settle, srs= particle density, g
11、/cm3,rf= fluid density, g/cm3, andu = rotational angular velocity, rad/s.4.2 The instruments that have been found suitable for thistest method incorporate microcomputers that control instru-ment operation and perform all required data acquisition andcomputation functions.5. Significance and Use5.1 M
12、anufacturers and users of advanced ceramic powderswill find this test method useful for determining the particlesize distribution of these materials for product specification,quality control, and research and development.6. Apparatus6.1 Centrifugal Particle Size Distribution AnalyzerTheanalyzer shal
13、l incorporate a centrifuge capable of subjecting anhomogeneous dispersion of the sample to centrifugal accelera-tion in specially designed sample cells. A collimated beam of1This test method is under the jurisdiction of ASTM Committee C28 onAdvanced Ceramics and is the direct responsibility of Subco
14、mmittee C28.03 onPhysical Properties and Performance.Current edition approved Jan. 1, 2006. Published January 2006. Originallyapproved in 1994. Last previous edition approved in 2000 as C 1282 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at
15、 serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.visible light (either monochromatic or broad-band)
16、 shalltraverse the sample cell at a defined distance from the top of thecell. The change in photo-extinction resulting from sedimen-tation of the sample shall be measured by a photo-detector andappropriate electronic circuits and used to calculate thevolume-based size distribution of the sample.6.2
17、Ultrasonic Probe, consisting of a 200 to 300-W powerunit, ultrasonic transducer, and 13-mm (12-in.) diameter probe.6.3 Balance, top-loading, accurate to 10 6 0.1 g.6.4 Stirrer, magnetic, with 25-mm (1-in.) and 19-mm (34in.) stirring bars.6.5 Thermometer, mercury or alcohol, 0 to 50C, accurate to0.5C
18、.6.6 Sample Cells, as supplied by the instrument manufac-turer.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American
19、Chemical Society,where such specifications are available.37.2 Darvan C4Dispersing FluidDissolve 5.0 g Darvan C(ammonium salt of polymethacrylic acid) in 95 cm3distilledwater (Note 3).NOTE 3These reagents are adequate to cover the range of samples upto a maximum particle diameter of 20 m.7.3 pH Adjus
20、tersFresh ammonium hydroxide (NH4OH)at 5 to 10 % strength is a common reagent used to raise pHwhile fresh nitric acid (HNO3) at 5 to 10 % strength is acommon reagent to lower pH.8. Procedure8.1 Sample Preparation and Dispersion:8.1.1 Add the appropriate sample mass of powder, usually 1g, to 250 cm3d
21、ispersing medium in a 500-cm3beaker. Thedispersing medium consists of 250 cm3of distilled water towhich 0.3 g of dispersing liquid is added.8.1.1.1 Sample DispersionPlace the beaker containingsample in an ice water bath so that the temperature of thesample does not exceed approximately 30C. Adjust t
22、he pH ofthe sample to 9.06 0.2 to ensure adequate dispersion aided bythe chemical environment. Deagglomerate the sample byinserting the ultrasonic transducer into the dispersing liquid/sample in a beaker. Ensure that the transducer is approximately10.0 mm above the bottom of the sample beaker. Apply
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC128220002006STANDARDTESTMETHODFORDETERMININGTHEPARTICLESIZEDISTRIBUTIONOFADVANCEDCERAMICSBYCENTRIFUGALPHOTOSEDIMENTATION

链接地址:http://www.mydoc123.com/p-464068.html