ASTM C1225-2008 Standard Specification for Fiber-Cement Roofing Shingles Shakes and Slates《纤维水泥屋面板、盖屋板和石板瓦的标准规范》.pdf
《ASTM C1225-2008 Standard Specification for Fiber-Cement Roofing Shingles Shakes and Slates《纤维水泥屋面板、盖屋板和石板瓦的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1225-2008 Standard Specification for Fiber-Cement Roofing Shingles Shakes and Slates《纤维水泥屋面板、盖屋板和石板瓦的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1225 08Standard Specification forFiber-Cement Roofing Shingles, Shakes, and Slates1This standard is issued under the fixed designation C 1225; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers fiber-cement shingles, shakes,and slates (roofing products) of nominally uniform thickness(non-tapered)
3、and texture, including accessories designed toprovide the weather-exposed surfaces on roofs of buildings.1.2 This specification is not applicable to asbestos-cementroofing shingles (Specification C 222), non-asbestos fiber-cement roofing shakes, shingles, and slates with designedvarying profiles and
4、 thicknesses (Specification C 1530), par-ticle board (Terminology D 1554), or cement-bonded particle-boards (Specification BS 5669: Part 4) and (ISO 8335).1.3 This specification does not include details of productinstallation or installed system performance. Refer to themanufacturers installation li
5、terature for proper installationinstructions, to Specification C 1459 for roofing systems per-formance, and to Test Methods E 108 for levels of fireresistance.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI un
6、its that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2C 222 Specification for Asbestos-Cement Roofing ShinglesC 1154 Terminology for Non-Asbestos Fiber-ReinforcedCement ProductsC 1185 Test Methods for Sampling and Testing Non-Asbestos Fi
7、ber-Cement Flat Sheet, Roofing and SidingShingles, and ClapboardsC 1459 Specification for Performance of Non-AsbestosFiber-Reinforced Cement Shake, Shingle, and Slate Roof-ing SystemsC 1530 Specification for Non-Asbestos Fiber-CementRoofing Shakes, Shingles, and Slates with Designed Vary-ing Profile
8、s and ThicknessesD 1554 Terminology Relating to Wood-Base Fiber andParticle Panel MaterialsE 108 Test Methods for Fire Tests of Roof Coverings2.2 British Standards:3BS 5669: Specification for cement bonded particleboard2.3 International Standards:3ISO 8335 Cement-bonded particleboardsBoards of Port-
9、land or equivalent cement reinforced with fibrous woodparticles33. Terminology3.1 DefinitionsRefer to Terminology C 1154.4. Manufacture and Composition4.1 ManufactureThese products may be formed eitherwith or without pressure and cured, either under natural oraccelerated conditions, to meet the phys
10、ical requirements ofthis specification.4.2 CompositionThis specification is applicable to fibercement roofing products consisting essentially of an inorganichydraulic binder or a calcium silicate binder formed by thechemical reaction of a siliceous material and a calcareousmaterial reinforced by org
11、anic fibers, inorganic non-asbestosfibers, or both. Process aids, fillers, and pigments which arecompatible with fiber cement may be added.5. Mechanical and Physical Properties5.1 Mechanical and physical properties shall be determinedon uncoated products wherever practical. Where products aresupplie
12、d coated, this material shall also be tested with theresults identified as applying to coated material. Failure of thecoating as a consequence of the mechanical testing shall notconstitute failure of the product. Accessory products shall beexcluded from these requirements.5.1.1 Sampling and inspecti
13、on for mechanical and physicalproperties shall be conducted in accordance with Test MethodsC 1185.6. Requirements6.1 Mechanical Requirements:1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of SubcommitteeC17.02 o
14、n Non-Asbestos Fiber Cement Products.Current edition approved May 1, 2008. Published May 2008. Originallyapproved in 1993. Last previous edition approved in 2004 as C 1225 04e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
15、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO
16、Box C700, West Conshohocken, PA 19428-2959, United States.6.1.1 Flexural StrengthWhen tested in accordance withTest Methods C 1185, the product shall be classified accordingto its modulus of rupture. The product modulus of rupture andbreaking moment in the primary strength direction shall be notless
17、 than that specified in Table 1.6.1.2 Where a manufacturer states a minimum productmodulus of rupture, it shall be at the 4 % acceptable qualitylevel (AQL) at the 90 % confidence limit as are the values ofTable 1.6.1.3 The primary strength direction is that heaviest loadeddirection which will resist
18、 wind uplift when the product isinstalled.6.1.3.1 Known Orientation of InstallationWhere the sys-tem design ensures or dictates that the product orientation atinstallation is known, and the product is manufactured suchthat its strongest direction coincides with the primary strengthdirection, then cl
19、assification of product shall be based on itsstrongest strength direction.6.1.3.2 Unknown Orientation of InstallationWhere a sys-tem design does not ensure or dictate that the product orienta-tion at installation is known, then classification of the productshall be based on its weakest strength dire
20、ction.6.1.4 The product modulus of rupture in the weakest direc-tion shall not be less than 50 % of the modulus of rupture in thestrongest direction.6.2 Physical Requirements:6.2.1 DensityNominal values and tolerances for densityshall be stated by the manufacturer, when tested in accordancewith the
21、method specified in Test Methods C 1185.6.2.2 Water AbsorptionCalculate the amount of waterabsorbed from the increase in weight of the dried specimenduring submersion for a period of 48 h. Express waterabsorption as the percentage by weight when tested in accor-dance with Test Methods C 1185.6.2.3 M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12252008STANDARDSPECIFICATIONFORFIBERCEMENTROOFINGSHINGLESSHAKESANDSLATES 纤维 水泥 屋面板 盖屋板 石板 标准规范

链接地址:http://www.mydoc123.com/p-463815.html