ASTM B667-1997(2003)e1 Standard Practice for Construction and Use of a Probe for Measuring Electrical Contact Resistance《测量电触点电阻用探测器的结构及使用标准操作规程》.pdf
《ASTM B667-1997(2003)e1 Standard Practice for Construction and Use of a Probe for Measuring Electrical Contact Resistance《测量电触点电阻用探测器的结构及使用标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM B667-1997(2003)e1 Standard Practice for Construction and Use of a Probe for Measuring Electrical Contact Resistance《测量电触点电阻用探测器的结构及使用标准操作规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 667 97 (Reapproved 2003)e1Standard Practice forConstruction and Use of a Probe for Measuring ElectricalContact Resistance1This standard is issued under the fixed designation B 667; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEKeywords were added editorially in December 2003.1. Scope1.1 This practice describes equipment and
3、 techniques formeasuring electrical contact resistance with a probe and thepresentation of results.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any,
4、 associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet for this product/material as pro-vided by the manufacturer, to establish appropriate safety andhealth practices, a
5、nd determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 542 Terminology Relating to Electrical Contacts andTheir Use3. Terminology3.1 DefinitionsMany terms used in this practice are de-fined in Terminology B 542.3.2 Definitions of Terms Speci
6、fic to This Standard:3.2.1 contact resistancethe resistance to current flowbetween two touching bodies, consisting of constriction resis-tance and film resistance.3.2.1.1 DiscussionConstriction resistance originates inthe fact that mating surfaces touch in most cases at only theirhigh spots, which a
7、re often called “asperities” or, morecommonly, a-spots. The current flow lines are then forced toconstrict as they funnel through these tiny areas. If oxide filmsor other insulating layers interfere with these metal-to-metalcontacts, the contact resistance will be higher than when suchlayers are abs
8、ent (see 4.4 for bulk resistance limitation).3.2.2 contact resistance probean apparatus for determin-ing electrical contact resistance characteristics of a metalsurface. Probe, in this instance, should be distinguished fromthe classical tool whose function it is to touch or move anobject.4. Signific
9、ance and Use4.1 Electrical contact resistance is an important characteris-tic of the contact in certain components, such as connectors,switches, slip rings, and relays. Ordinarily, contact resistance isrequired to be low and stable for proper functioning of manydevices or apparatus in which the comp
10、onent is used. It is moreconvenient to determine contact resistance with a probe than toincorporate the contact material into an actual component forthe purpose of measurement. However, if the probe contactmaterial is different from that employed in the component, theresults obtained may not be appl
11、icable to the device.4.2 Information on contact resistance is useful in materialsdevelopment, in failure analysis studies, in the manufacturingand quality control of contact devices, and in research.4.3 Contact resistance is not a unique single-valued propertyof a material. It is affected by the mec
12、hanical conditions of thecontact, the geometry and roughness of contacting surfaces,surface cleanliness, and contact history, as well as by thematerial properties of hardness and conductivity of bothcontacting members. An objective of this practice is to defineand control many of the known variables
13、 in such a way thatvalid comparisons of the contact properties of materials can bemade.4.4 In some techniques for measuring contact resistance it isnot possible to eliminate bulk resistance, that is, the resistanceof the metal pieces comprising the contact and the resistance ofthe wires and connecti
14、ons used to introduce the test current into1This practice is under the jurisdiction of ASTM Committee B02 on NonferrousMetals and Alloys and is the direct responsibility of Subcommittee B02.11 onElectrical Contact Test Methods.Current edition approved Dec. 9, 2003. Published December 2003. Originall
15、yapproved in 1980. Last previous edition approved in 1997 as B 667 97.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
16、 website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the samples. In these cases, the measurement is actually of anoverall resistance, which is often confused with contact resis-tance.5. General Description of a Probe5.1 A probe
17、generally includes the following:5.1.1 Fixtures for holding specimens of varied size andshape and for attaching electrical leads to them.5.1.2 A mechanism that applies a measurable load to thespecimen that can be increased, decreased, or held constant.5.1.3 A shock mounted table to prevent any indig
18、enousvibrations from inadvertently altering the conditions at thecontact interface.5.1.4 A reference surface (the probe) that is pressed againstthe specimen and which is normally made of a noble metal.Noble metals such as pure gold are used because they aresubstantially free of oxide films and have
19、the best likelihood ofobtaining reproducible results.5.1.5 A current source with current and voltage measuringinstrumentation for determining contact resistance. Ordinarily,contact resistance is determined at dry circuit conditions3toavoid changes that may occur due to voltage breakdown orheating at
20、 the contact interface.5.2 Additional electrical circuitry may be included to permitrelated measurements to be obtained, such as the voltagebreakdown or the current versus voltage characteristics offilm-covered surfaces.5.3 Probes are also convenient for determining the depen-dence of contact resist
21、ance on sliding or wipe when a slide isincorporated in the specimen holder. This permits the probe tobe moved small measurable distances after loading.6. Design Aspects6.1 The probe is mounted on one end of a pivoted beam, acantilever, or a coil spring. Force is applied by dead weight,compression of
22、 the spring, bending of the cantilever, orelectromagnetically.6.2 Probe holders have been designed so that force may beapplied to the contact and to an electronic load cell which ismounted between the probe contact and a micrometer spindlethat can be advanced. An alternative design is to mount thesp
23、ecimen on the load cell and to advance the probe directlywith the micrometer spindle. Load and contact resistance arethe usual parameters measured and recorded simultaneously.6.3 A probe can be made by mounting a U-shaped free-standing gold wire to the micrometer spindle (see Fig. 1(b).The load is m
24、easured after the probe is observed (preferablyelectrically) to first touch the specimen from a preliminarycalibration (with a load cell) of micrometer advance versusload. In some cases, where very small (to tens of milligrams)forces are used, it may not be necessary to know the loadprecisely. In su
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB66719972003E1STANDARDPRACTICEFORCONSTRUCTIONANDUSEOFAPROBEFORMEASURINGELECTRICALCONTACTRESISTANCE

链接地址:http://www.mydoc123.com/p-461917.html