ASTM A820 A820M-2011 Standard Specification for Steel Fibers for Fiber-Reinforced Concrete《纤维强化混凝土钢纤维的标准规格》.pdf
《ASTM A820 A820M-2011 Standard Specification for Steel Fibers for Fiber-Reinforced Concrete《纤维强化混凝土钢纤维的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM A820 A820M-2011 Standard Specification for Steel Fibers for Fiber-Reinforced Concrete《纤维强化混凝土钢纤维的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A820/A820M 11Standard Specification forSteel Fibers for Fiber-Reinforced Concrete1This standard is issued under the fixed designation A820/A820M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers minimum requirements forsteel fibers intended for use in fiber-reinforced concrete. Fivetypes of steel
3、fibers for this purpose are defined as pieces ofsmooth or deformed cold-drawn wire; smooth or deformed cutsheet; melt-extracted fibers; mill-cut or modified cold-drawnwire steel fibers that are sufficiently small to be dispersed atrandom in a concrete mixture.1.2 This specification provides for meas
4、urement of dimen-sions, tolerances from specified dimensions, and requiredminimum physical properties, and prescribes testing proce-dures to establish conformance to these requirements.1.3 In the case of conflict between a requirement of aproduct specification and a requirement of this specification
5、,the product specification shall prevail. In the case of a conflictbetween a requirement of the product specification or arequirement of this specification and a more stringent require-ment of the purchase order, the purchase order shall prevail.The purchase order requirements shall not take precede
6、nce ifthey, in any way, violate the requirements of the productspecification or this specification; for example, by the waivingof a test requirement or by making a test requirement lessstringent.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. Th
7、e values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.2. Referenced Documents2.1 The following documents, of the issue in effect on thedate of mat
8、erial purchase, form a part of this specification tothe extent referenced herein.2.2 ASTM Standards:2A370 Test Methods and Definitions for Mechanical Testingof Steel ProductsA700 Practices for Packaging, Marking, and Loading Meth-ods for Steel Products for ShipmentC1116/C1116M Specification for Fibe
9、r-Reinforced Con-crete2.3 ACI Documents:3ACI 506.1 Guide to Fiber-Reinforced ShotcreteACI 544.1R Committee Report on Fiber-Reinforced Con-crete2.4 U.S. Federal Standards:4Fed. Std. No. 123 Marking for Shipment (Civil Agencies)2.5 U.S. Military Standards:4MIL-STD-129 Marking for Shipment and Storage3
10、. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 deformed fiber, na fiber that is bent, flattened, orroughened to improve mechanical bond to the concrete matrix.3.1.2 modified fiber, na cold-drawn wire fiber whosecross-section has been changed from circular by shaving thewire.3.
11、1.3 nominal length, nthe length of a deformed fiber,out-to-out, after being deformed.3.1.4 range of equivalent diameter, de-r, na set of limitsplaced on the equivalent diameter by the specifier. See 8.1.6and Note 3.3.2 SymbolsThe following symbols used in this specifi-cation are defined as follows:A
12、 = cross-sectional area, in.2mm2d = diameter, in. mmfu= ultimate tensile strength, psi MPal = length, in. mml = l/d = aspect ratio1This specification is under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.05 on
13、Steel Reinforcement.Current edition approved Oct. 1, 2011. Published October 2011. Originallyapproved in 1985. Last previous edition approved in 2006 as A820/A820M 06.DOI: 10.1520/A0820_A0820M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at
14、 serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, MI 48333-9094, http:/www.concrete.org.4Available from Standardization Documents Or
15、der Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1 The
16、 subscript n on dimensional units indicates “nomi-nal” and the subscript e indicates “equivalent.” “Nominal” and“equivalent” dimensions are calculated from other measurabledimensions or average weight mass.4. Classification4.1 Five general types of steel fibers are identified in thisspecification ba
17、sed upon the product or process used as asource of the steel fiber material.4.1.1 Type I, cold-drawn wire.4.1.2 Type II, cut sheet.4.1.3 Type III, melt-extracted.4.1.4 Type IV, mill cut.4.1.5 Type V, modified cold-drawn wire.4.2 Fibers shall be straight or deformed.5. Ordering Information5.1 It shal
18、l be the responsibility of the purchaser to specifyall requirements that are necessary for the product under thisspecification. Such requirements to be considered include, butare not limited to, the following:5.1.1 ASTM designation and year of issue,5.1.2 Quantity in pounds or tons kilograms,5.1.3 T
19、ype or types permissible (4.1),5.1.4 Diameter or equivalent diameter (8.1.4), or range ofequivalent diameters (8.1.6),5.1.5 Length or nominal length (3.1.3),5.1.6 Deformations, if required, and5.1.7 Whether certification by the manufacturer is requiredincluding whether a report is to be furnished (S
20、ection 11).NOTE 1For information on satisfactory sizes and aspect ratios, seeACI 544.1R and ACI 506.1, and contact the manufacturers regardingavailability.6. Materials and Manufacture6.1 The materials and manufacturing methods used shall besuch that the fibers produced conform to the requirements in
21、this specification.7. Mechanical Properties7.1 Tensile Requirements:7.1.1 At least ten individual tensile tests of randomlyselected finished fibers shall be performed for each 5 tons4 500 kg of product. This is an approximate distribution ofone fiber tensile test per every 0.5 ton 450 kg of finished
22、product. The average tensile strength, fu, of each fiber shall notbe less than 50 000 psi 345 MPa. The tensile strength of anyone of the ten specimens shall not be less than 45 000 psi310 MPa. Where the parent source material consists of sheetor wire, tensile tests by the manufacturer may be perform
23、ed onlarger samples of source material. One sample of each differentsource material used shall then be tested for each 5 tons4 500 kg of material. The tensile strength of a single sampleof source material shall not be less than 50 000 psi 345 MPa.7.1.2 The cross-sectional area used to compute fushal
24、l becarried out to five decimal places, in units of square inchessquare millimetres, and shall be: (1) for drawn wire fibers,Type I, the area calculated from the actual diameter of theparent source material or finished fiber; (2) for cut sheet fibers,Type II, the area calculated from the actual thic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA820A820M2011STANDARDSPECIFICATIONFORSTEELFIBERSFORFIBERREINFORCEDCONCRETE 纤维 强化 混凝土 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-459668.html