ARMY MIL-S-52028 C-1988 SWITCH VEHICULAR IGNITION WATERPROOF STARTER AND MAGNETO WITH DEGASSER CONTROL《带脱气控制的磁电启动的防水的汽车点火开关》.pdf
《ARMY MIL-S-52028 C-1988 SWITCH VEHICULAR IGNITION WATERPROOF STARTER AND MAGNETO WITH DEGASSER CONTROL《带脱气控制的磁电启动的防水的汽车点火开关》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-S-52028 C-1988 SWITCH VEHICULAR IGNITION WATERPROOF STARTER AND MAGNETO WITH DEGASSER CONTROL《带脱气控制的磁电启动的防水的汽车点火开关》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、NIL-S-52028C 59 = 9999906 0415902 5 A -as- 63 MIL- S-5 20 28 C 27 January 1988 SUPERSEDING MIL-S-52028B 11 October 1967 MILITARY SPECIFICATION SWITCH, VEHICULAR IGNITION : WATERPROOF, STARTER AND MAGNETO, WITH DEGACSER CONTROL This specification is approved for use by all Departments and Agencies of
2、 the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers ignition switches for controlling magnetos and auxiliary equipment on engines in military vehicles. 2. APPLICABLE DOCUMENTS 2.1 Government documents. * 2.1.1 Specifications and standards. The following specifications and stand
3、ards form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation. Beneficia
4、l comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: US Army Tank-Automotive Command, ATTN: AMSTA-GDS, Warren, MI 48397-5000, by using the self-addressed Standardization Document Improvement Proposal (DD Form
5、 1426) appearing at the end of this document, or by letter. AMSC NIA FSC 5930 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS / 3 PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-S-5
6、2028C 59 9 9999906 0435903 7 i- MIL-S-52028C SPEC1 F I CAT IONS FEDERAL QQ-A-59 1 QQ-S-57 1 - Aluminum Alloy Die Castings. - Solder, Tin Alloy: Tin-Lead Alloy; and Lead Alloy. MILITARY MIL-M- 14 - MIL-F-13927 - MI1-C-46168 - MIL-C-53039 - STANDARDS FEDERAL FED- STD-H28 - MILITARY MIL-STD-105 - MIL-
7、STD- 1 3 O MIL-STD-193 - - MIL- STD- 202 MIL-STD-1184 - MIL-STD-45662 c MS24570 - (Copies of specifications and Molding Plastics and Molded Plastic Parts, Thermosetting . Fungus Resistance Test; Automotive Components. Coating, Aliphatic Polyurethane, Chemical Agent Resistant. Coating, Aliphatic Poly
8、urethane, Single Component, Chemical Agent Resistant. Screw-Thread Standards for Federal Services . Sampling Procedures and Tables for Inspection by Attributes. Identification Marking of US Military Property. Painting Procedures and Marking for Vehicles, Construction Equipment and Material Handling
9、Equipment. Test Methods for Electronic and Electrical Component Parts. Electrical Components for Automotive Vehicles; Waterproofness Tests. Calibration Systems Requirements. Switch, Vehicular Ignition: Waterproof, Starter and Magneto, with Degasser Control. standards required by the contractors in c
10、onnection with specific acquisition functions -should be obtained from the contracting activity or as directed by the contracting activity.) * 2.2 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein (except for the MS standard), the
11、text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-S-5202C 54
12、I 9999906 0415904 9 I * sha MIL-S-52028C 3 . REQUIREMENTS 3.1 First article. Unless otherwise specified (see 6.2), 1 furnish switches wich shall be subjected to first artic the contractor e inspection (see 4.5). First article inspection samples, properly marked with identifying information, shall be
13、 representative of the units to be furnished to the Government. All subsequent switches delivered to the Government shall conform to these samples in all of their pertinent physical and performance attributes. 3.2 Materials. Materials shall be as specified herein, in applicable specifications, and o
14、n applicable drawings (see 4.8.1). 3.2.1 Dissimilar metals. Except where necessary to complete an electrical circuit, contact between dissimilar metals, which would encourage galvanic action, shall be avoided. Separation of dissimilar metals shall be accomplished by providing insulation between mati
15、ng surfaces (see 4.8.1). * 3.2.2 Aluminum castings. Aluminum castings shall conform to alloy A380.0 or 413.0 of QQ-A-591 (see 4.8.1). 3.2.3 Molded plastic insulating material. Molded plastic insulating material shall conform to type MFE of MIL-M-14 (see 4.5.1). 3.2.4 Solder. Solder shall conform to
16、composition Sn50 or Sn60 of QQ-S-571. A rosin flux shall be used (see 4.8.1). * 3.2.5 Recycled, virgin and reclaimed materials. There are no requirements for the exclusive use of virgin materials. The use of recycled or reclaimed (recovered) materials is acceptable provided that all other requiremen
17、ts of this specification are met (see 6.3.1). 3.3 Design and construction. Unless otherwise specified (see 6.2), the switch shall conform to MS24570 (see 4.8.1 and 4.8.2). 3.3.1 Standard parts. Military standard parts shall be incorporated wherever applicable. Commercial standard parts may be used p
18、rovided they are interchangeable with military standard parts without modification, and the .1 equivalent military standard part is identified by the manufacturer (see 4.8.1). 3.3.2 Locking devices. Lockwashers, self-locking nuts, or other approved locking devices shall be incorporated where specifi
19、ed or where required to prevent loosening of components (see 4.8.1). 3.3.3 Springs. Springs shall not be used to transmit current (see 4.8.1). 3.3.4 Threaded parts. Screw threads shall conform to PED-STD-H28 (see 4.8.1) . 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without
20、 license from IHS-,-,-MIL-S-5202C 59 E 9999906 0435705 O MIL-S-52028C 3.3.5 Weight. The weight of the switch shall be as specified on the applicable military standard (see 4.8.3). 3.4 Physical requirements. 3.4.1 Lever torque. The torque required to move each lever to its operating position, at temp
21、eratures of -65 degrees Fahrenheit (OF) to 165OF, shall be 3 to 6 pound-inches for the MAGNETOS lever and 7 to 11 pound-inches for the START and BOOST levers. Each lever, when in its operating position, shall withstand a torque of not less than 3 pound-feet without damage at temperatures of -65 to 1
22、65F. requirements of 3.5.1 (see 4.8.4.1). “ The switch shall subsequently meet the 3.4.2 Plunger force. The force required to depress the DEGASSER plunger to its operating position, at temperatures of -65 to 165OF, shall be 7 + 3 pounds. The plunger shall have positive spring return and shall turn r
23、adially in either direction without drag or binding (see 4.8.4.2). 3.4.3 Vibration. Shen tested as specified in 4.8.4.3, the switch shall show no evidence of intermittent or accidental circuit operation and shall subsequently meet the requirements of 3.5.1 and 3.5.3. 3.4.4 Shock. When tested as spec
24、ified in 4.8.4.4, the switch shall show no evidence of intermittent or accidental circuit operation and shall subsequently meet the requirements of 3.5.1 and 3.5.3. 3.5 Electrical requirements. 3.5.1 Circuit continuity. Circuits shall provide continuity through the switch at the various positions of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILS52028C1988SWITCHVEHICULARIGNITIONWATERPROOFSTARTERANDMAGNETOWITHDEGASSERCONTROL 脱气 控制 磁电 启动 防水

链接地址:http://www.mydoc123.com/p-448124.html