1、flIL-PRF-62259B 9999906 2069233 394 1 INCH-POUND I MIL-PRF-62259B 26 June 1998 SUPERSEDING 28 September 1980 (See 6.3) MIL- R-62259A(AT) PERFORMANCE SPECIFICATION RADIATOR: ENGINE COOLANT This specification is approved for use by ail Departments and Agencies of the Department of Defense. 1. SCOPE 1.
2、1 Scope. This specification covers engine coolant radiators used on Howitzer, Medium, Self-propelled, models M 109 and M 109A 1. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are referenced in sections 3 and 4 of this specification. This section does not include documents
3、 in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet ail specified requirement documents cited in Section 3 and 4 of this specifica
4、tion, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those list
5、ed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may improve this document should be addressed to: U.S. Arm
6、y Tank-automotive and Armaments Command, AITN: AMSTA-TR-EBLE, Warren, MI 48397-500, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by letter ASMC N/A FSC 2930 DISTRIBUON STATEMENT A. Approved for public release; distribution is unl
7、imited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PE-62259B SPECIFICATIONS FEDERAL A-A-870 - Antifreeze. A-A-52624 - Antifreeze, Multi Engine Type, (Unless otherwise indicated, copies of the above specifications, standards, and handbooks ar
8、e available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 1 1-5094.) 2.3 Non-Government publications. The following document(s) form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents w
9、hich are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). AIR MOVEMENT AND CONTROL ASSOCIATION (AMCA) Bulletin 210 - Met
10、hod of Testing Fans (DoD Adopted). (Application for copies should be addressed to the Air Movement and Control Association, 30 W. University Drive, Arlington Heights, IL 60004.) GENERAL MOTORS CORPORATION GM 9540P - Accelerated Corrosion Test. (Application for copies should be addressed to General M
11、otors Corporation, c/o Global Engineering Documents, 15 Inverness Way East, Englewood, CO 801 12.) 2.4 Order of precedence. If there is a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, superse
12、des applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2 and 6.4), a sample shall be subjected to first article inspection. 3.2 Design, - materiais, and manufacturing processes. Unless otherwise specifkd herein, the
13、 design, materials and manufacturing process selection shall be the prerogative of the contractor provided the radiator is able to serve as a drop-in replacement on howitzer models M109 and M109A1. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-fl
14、IL-PRF-bZ259B 9999906 2069233 Lb7 MIL-PRF-62259B 3.2.1 Recycled. recovered, or environment preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided the material meets or exceeds all specified requirements and promotes e
15、conomically advantageous life cycle costs. 3.3 Operating requirements. 3.3.1 Heat transfer capacity. The heat transfer capacity, based on the unobstructed area of the core, shall not be less than shown on figure 1. 3.3.2 Air flow resistance. The maximum static air flow resistance shall not be more t
16、han that shown on figure 1. 14500 1 13000 o n a k 7.0 6.5 6.0 5.5 5 .O 4.5 4.0 3.5 3 .O 2.5 2.0 1.5 1 .o .5 O e ia 3 O AIR FLOW LBS MIN (FACE VELOCITY) (AIR CORRECTED TO 0.075 LBS / CU. FT.) FIGURE 1. Btu rating of radiator. 3.3.3 Coolant flow resistance. The maximum coolant flow resistance at 94 ga
17、lions per minute (gaymin) (5.9 liters per second (Lh) coolant flow rate shall not be more than 3.0 pounds per square inch (psi) (20.7 kilopascal (kPa). 3.3.4 Pressure cycle. Radiators shall withstand a minimum of 10 O00 air pressure cycles at 6 cycles per minute without rupturing or leaking. 3.3.5 P
18、ressure capacitv. Radiators shall withstand an internal pressure of 18 pounds per square in gauge (psig) (124.1 kPa) for a period of not less than 0.5 .linute (or approved alternate 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PFG62259B regi
19、me, see 4.3. I) without evidence of rupture, permanent deformation of internal or external parts, or leakage. 3.3.6 High pressure capaciw. Radiators shall withstand 25 psig (172 kPa) for 5 minutes, with not more than 3 cubic centimeters (a3) per minute leakage evident, when the radiator is submerged
20、 in water under test pressure. Deformation, but not rupture, is permitted. 3.4 Interface requirements. 3.4.1 Functional fit. The radiator shall serve as a dropin replacement for the models M 109 and M 109A 1. Complete interface and interoperability shall be achieved without engine compartment modifi
21、cation. The radiator shall interface and be interoperable without engine compartment modification. Interface dimensions are as indicated in figure 2 (see 6.6). Radiator mounting facilitators, bushings or brackets if used, shall be the prerogative of the manufacturer as long as all the requirements o
22、f the specification are met (see 6.6). ygfp :-.-A FIGURE 2. Interface and interoperability dimensions. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-PRF-bZ259B 9999906 2069235 T3T U MIL-PFW-62259B 3.4.2 Assembly. The manufacturers method of
23、assembling radiator components shall not interfere with the functional interface of the radiator pressure cap or of vehicle components necessary for cooling system operation. 3.4.3 Dissimilar metals. The radiator shall be constructed of materials designed to minimize galvanic corrosion in dissimilar
24、 metal couples. 3.5 Support and ownership requirements. 3.5.1 Safety. The radiator construction shall minimize the risks to personnel fom burrs, sharp edges and avoidable scalding risks. 3.5.2 Lifting eye. The lifting eye or equivalent lifting facilitator, as installed, shall withstand a 300 pound (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62259B1998RADIATORENGINECOOLANT 引擎 冷却液 散热器 PDF

链接地址:http://www.mydoc123.com/p-447553.html