ARMY MIL-P-48619-1979 PERISCOPE TANK M32CE1《M32CE1式坦克潜望镜》.pdf
《ARMY MIL-P-48619-1979 PERISCOPE TANK M32CE1《M32CE1式坦克潜望镜》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-P-48619-1979 PERISCOPE TANK M32CE1《M32CE1式坦克潜望镜》.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-P-ibL7 L2 777770b 0322333 5 - MIL-P-48619 (AR) 30 April 1979 MILITARY SPECIFICATION PERISCOPE, TANK: M32CE1 This specification is approved for use by the U.S. Army Armament Research and Development Command, and is available for use by all Departments and Agencies of the Department of Defense. 1.
2、 SCOPE 1.1 This specification covers one type of combination passive- daylight tank gunners periscope designated Periscope, Tank: M32CE1. The periscope is a part of the fire control system in the 165MM Gun, Combat Engineering Vehicle: M728 and is used for day and night sighting and observing. 2. APP
3、LSCABLE WCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposal form-a part of this specification to the extent specified. SPECIFICATIONS Mil i tar y MIL-F-13926 MIL-P-14 232 MIL-1-45607 MIL-E-48441 MIL-B-50645 MIL-H-48620 Fire Control Mate
4、riel: General Specification Governing the Manufacture and Inspection of Parts, Equipment and Tools for Army Materiel, Packaging and Packing of Inspection Equipment, Acquisition, Maintenance and Disposition of Elbow Assembly, Passive: 11733401 Body (Daylight) Assembly: 10516576 Head Assembly:,r 10 lb
5、-ins at extreme temper- atures of -40 and +15O0F: Diopter movement - Daylight and Pascive.-The running torque required to rotate the daylight diopter movement through a minimum range of minus 3.0 to plus 3.0 diopters and the passive diopter movement through a minimum range of minus 4.0 to plus 4.0 3
6、.5.2 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-48bL7 LE! 9 7777706 0322334 O 9 - MIL-P-4 8 6 19 (AR) diopters shall be within the limits of 1.5 and 6.0 lb-ins when checked at standard ambient temperature. When checked at the temperature
7、 conditions specified in 3.4.2, the running torque shall not exceed 15 lb-ins. 3.5.3 Focusing mechanism - Passive.-The running torque required to rotate Ring 11733436 through the range specified in 3.8.7 shall be within the limits of 4.0 and 14.0 lb-ins when checked at standard ambient temperature.
8、When checked at the temperature conditions specified in 3.4.2, the running torque shall not exceed 24.0 lh-ins. 3.5.4 Disengagement of boresight knob locks - Daylight and Passive.-The direct force required to disengage each boresight knob from the lock position shall be within the limits of 2.0 and
9、5.0 pounds (lbs) when checked at standard ambient temperature. When checked at the temperature conditions specified in 3.4.2, the direct force shall not exceed 9.0 lbs. 3.5.5 Rotation of boresight knobs - Daylight and Passive.-The runninq torque required to rotate each boresight knob through the tra
10、vel-range speccfied in 3.8.3.1.1 and 3.8.3i1.2 respectively, shall be within the limits of 0.5 and 5.0 lb-ins when checked at standard ambient temperature. When checked at the temperature conditions specifiedsin 3.4.2, the running torque shall not exceed 8.0 lb-ins. 3.5.6 Shutter lever and on-off sw
11、itch - Passive.-The torque required to rotate the shutter from the off to on position shall be within the limits of 4.5 to 6.5 lb-ins when checked at standard ambient temperature. When checked at the temperature conditions specified in 3.4.2, the torque shall not exceed 10 lb-ins. Gain adjust and re
12、ticle - brightness control - Pass-.- This requirement shall be met at standard ambient temperature and the temperature conditions specified in 3.4.2. Knob MS91528-OE1B shall be manually operable through the full limits of the rheostat. FZ.-This requirement shall be met . with a 10 lb-ins torque appl
13、ied to the locking screw on Housing 11727432. When checked at standard ambient temperature and the temperature conditions specified in 3.4.2, there shall be no rotation of Eccentric 8205635 when a 48 ounce-i,.nches (oz-ins) torque is applied to the eccentric. 3.5.7 3.5.8 4 Provided by IHSNot for Res
14、aleNo reproduction or networking permitted without license from IHS-,-,- MIL-P-48619 (AR) 3.5.9 Objectivefocusing mechanism - Daylight.-This requirement shall be met-with the locking screw backed off a minimum of two full revolutions from the locked position established in 3.5.8. The running torque
15、requirea to rotate Eccentric 8205635 through a minimum of one full revolution in each direction shall not exceed 30 oz-ins when checked at standard ambient: temperature. When checked at the temperature conditions specified in 3.4.2, the running torque shall not exceed 50 oz-ins. 3.6 Vibration/Shock.
16、 3.6.1 Vibration “A“.-This requirement shall be met with the image intensifier tube and reticle projector lamp energized by the application of +24 4 6.0 VDC to Contact 11733497 (Reference Drawing 11733401). The vibration input to the periscope shall be at the interface of the periscope and mount. Vi
17、bration shall be applied along each of three mutually perpendicular axes of the periscope. The vibration shall be sinusoidal as follows: a. At a frequency of 5 Hertz (Hz) , the acceleration shall be .5G - t 10%. b. During a frequency sweep of 5 to 9 HZ, increase acceler- ation linearly from .5G to 1
18、.5Gls - + 10%. C. During a frequency sweep of 9 to 500 Hz, maintain constant d. During a requency sweep of 500 to 9 Hz, maintain constant e. During a frequency sweep of 9 to 5 Hz, decrease acceler- - f. At 5 Hz, the acceleration shall be .5G 5 10%. acceleration of 1.5Gs 5 10%. acceleration of 1.5Gs
19、2 10%. ation linearly from 1.5Gs to .5G 5 10%. The frequency of applied vibration shall be swept logarithmically in 15 minute 2 1 minute sweep cycles for a total of two hours per axis. There shall be no failure or flicker of light emission from the image intensifier tube nor the reticle projector la
20、mp during vibration and the periscope shall show no evidence of physical failure subsequent to vibration. Following the vibration test, the periscope shall meet the requirements of 3.8.3.2, 3.8.4.1, 3.8.9, 32, 3.1, 3.7 and then each module (see 3.1) shall meet their own respective post-vibration tes
21、t requirements. 3-8.2, 3.8.3.1.11 3.8.3.1-2, 3.8.5, 3.8.6, 3.8.6.1, 3-8-71 3-8.8, 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-48619 (AR) 3.6.2 Vibration “B“.-This requirement shall be met with the image intensifier tube and reticle projec
22、tor lamp energized by the application of +24 + 6.0 WC to Contact 11733497 (Reference Drawing 11733401). The vibration input to the periscope shall be at the interface of the periscope and mount. Vibration shall be applied along each of three mutually perpendicular axes of the per iscope. The vibrati
23、on shall be sinusoidal as follows: a. At a frequency of 5 Hertz (Hz) , the acceleration shall be b. During a frequency sweep of 5 to 500 Hz, maintain constant C. During a frequency sweep of 500 to 5 Hz, maintain constant d. At 5 Hz, the acceleration shall be 1.OG $: 10%. acceleration of 1.OG 5 10%.
24、acceleration of 1.OG 5 10%. The frequency of applied vibration shall be swept logarithmically in 15 minute + 1 minute sweep cycles for a total of 15 minutes f. 1 minute aloEg each of the three mutually perpendicular axes (total vibration time 45 minutes + 3 minutes). There shall be no failure or fli
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP486191979PERISCOPETANKM32CE1M32CE1 坦克 潜望镜 PDF

链接地址:http://www.mydoc123.com/p-446415.html