ARMY MIL-C-71150 (5)-2000 CARTRIDGE 60MM PRACTICE SHORT RANGE M766 LOADING ASSEMBLING AND PACKING《 tM766型60MM炮弹近程实践的装载 组装及包装》.pdf
《ARMY MIL-C-71150 (5)-2000 CARTRIDGE 60MM PRACTICE SHORT RANGE M766 LOADING ASSEMBLING AND PACKING《 tM766型60MM炮弹近程实践的装载 组装及包装》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-C-71150 (5)-2000 CARTRIDGE 60MM PRACTICE SHORT RANGE M766 LOADING ASSEMBLING AND PACKING《 tM766型60MM炮弹近程实践的装载 组装及包装》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、INCH- POUND I MIL-C-71150 (AR) AMENDMENT 5 SUPERSEDING AMENDMENT 4 11 February 2000 9 September 1998 MILITARY SPECIFICATION CARTRIDGE, 60MM PRACTICE, SHORT RANGE, M766 LOADING, ASSEMBLING AND PACKING This amendment forms a part of MIL-C-71150 (AR), dated 1 November 1993, and is approved for use by t
2、he U.S. Army Armament Research, Development and Engineering Center, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 2 DRAWINGS, Delete: 6.5” , and substitute: 6.4”. Delete: QUALITY ASSURANCE PROVISIONS . QAP Cl2961001 - Dud Plug” . PAGE 4 3.3.7.2 Delete in
3、 its entirety. 3.4.4: Delete in its entirety and substitute: “3.4.4 Range and deflection precision. The cartridge shall have a horizontal range probable error (PEr) less than 15 meters for all zones when calculated to the nearest one tenth (0.1) meter. The deflection probable error (PEd) shall be le
4、ss than 15 meters for all zones when calculated to the nearest one tenth (0.1) meter) .I1 1 of 7 AMSC N/A FSC 1315 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C
5、-71150 (AR) AMENDMENT 5 PAGE 5 3.4.9.1: Delete in its entirety and substitute: “3.4.9.1 Functioned round. All dud plug heads (regardless of stems) shall blow out of the projectile body upon fuze function. 3.4.9.2: Delete in its entirety and substitute: “3.4.9.2 Inert round. No dud plug head (regardl
6、ess of stems) shall exit the projectile body during ballistic flight or upon impact.“ PAGE 6 4.3.3, delete requirement Ilb.“ in its entirety and substitute: “b. Three or more duds occur.11 Delete Ilg.Il and iih.ll in their entirety and substitute: Ilg. If the weapon is damaged by abnormal wear of th
7、e interior or of the firing pin, or caused by excessive pressure. h. Two or more improper impact signatures occur.11 Add the following: 11 1 . All three dud plug heads (regardless of stems) are missing from the projectile body in the inert fuze ballistic test. j. More than one dud plug head (regardl
8、ess or stems) remains in a single projectile body upon fuze function except in the case of a particular round that was an actual dud. In this case, paragraph Ili.“ Above applies. PAGE 7 Table I, Delete under Dud Plug and subsitute the following: “Dud Plug . . . (dwg. 12988971) Examination for defect
9、s . lO(a) . 3.1 . 4.4.2.9 Add Note: !(a) Ten (10) samples are required from each mold cavity. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-71150 (AR) AMENDMENT 5 * Table I, Delete: IlPlug, Increment“ and substitute: “Increment Plug“ Delete
10、: Ii(Dwg. 12944200)“ and substitute: Ii(Dwg. 12991840) PAGE 10 4.4.2.1, Major 105: Delete: “Length of large outside diameter section“, and substitute: “Length between large outside diameter aft face to firing pin point!. PAGE 13 4.4.2.3, Major 102: Delete the word Ilexcessive“ and substitute the wor
11、d Ilinadequate“ . PAGE 14 * 4.4.2.4, Delete Title: “Plug, Incrementll and substitute: Increment Plugll Delete Dwg. Number: “12944200“ and substitute: “12991840“ Add Major Defect 107 Under Examination or Test: IIIncrement plug pull test“ Under Conformance Criteria: “V“ Under Requirement Paragraph : I
12、l3 .3 .5 Under Inspection Method Reference: IlTestIl Add Major Defect 108 Under Examination or Test: “Longitudinal length of slit“ Under Conformance Criteria: Under Requirement Paragraph: ii3.111 Under Inspection Method Reference: iiGagell 3 Provided by IHSNot for ResaleNo reproduction or networking
13、 permitted without license from IHS-,-,-MIL-C-71150 (AR) AMENDMENT 5 CLASSIFICATION Critical 1 PAGE 14 (contd) EXAMINATION OR TEST Fuze striker in armed positic Add Minor Defect 204 2 3 Major 108 109 110 111 112 Under Examination or Test: “Width of slit“ Breech plug assembly firing pin not below flu
14、sh after assembly to round Powder from energetic cartridges found on outside ( round Obturator ring missing Fin tail cracked, damaged or distorted Fuze packing clip missing or improperly assembled Cartridge assembly fails to fully enter complete round alignment gage Any dud plugs missing Under Confo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC7115052000CARTRIDGE60MMPRACTICESHORTRANGEM766LOADINGASSEMBLINGANDPACKINGTM766 60 MM 炮弹 近程 实践

链接地址:http://www.mydoc123.com/p-442266.html