AIR FORCE A-A-59418-2003 METER MODULATION (150 KHZ TO 1.3 GHZ)《调制表(150千赫至1.3吉赫)》.pdf
《AIR FORCE A-A-59418-2003 METER MODULATION (150 KHZ TO 1.3 GHZ)《调制表(150千赫至1.3吉赫)》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59418-2003 METER MODULATION (150 KHZ TO 1.3 GHZ)《调制表(150千赫至1.3吉赫)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 A-A-59418 19 December 2003 . COMMERCIAL ITEM DESCRIPTION METER, MODULATION (150 kHz to 1.3 GHz) The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies 1. SCOPE. This Commercial Item Description (CID) describes a FM/AM Modulation
2、 meter. This instrument gives a complete accurate characterization of modulated signals in the frequency range of 150 kHz to 1.3 GHz. This CID is meant as a minimum requirement for the modulation meter, in which only those manufacturers that meet or surpass the following requirements are supplied pe
3、r this CID. 2. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within the accuracies, limits, and specifications herein. Equipment covered by this CID may be commercially available equipment modified to the extent necessary to meet the following description. The equipment shall
4、be Class 3 in accordance with MIL-PRF-28800 except as specified herein. 2.3 Safety and Environmental. The equipment shall meet all safety and environmental requirements as specified in MIL-PRF-28800 for the classification as stated herein. 2.4 Reliability. The design of the equipment shall be such t
5、hat under normal use and operation the equipment does not fail within 2000 hours of operation with a statistical certainly of 95%. AMSC N/A FSC 6625 INCH-POUNDBeneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent t
6、o: WR-ALC/LEEC, 295 Byron Street, Robins AFB, GA 31098-1611 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59418 22.5 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible calibration and maintena
7、nce adjustments. These adjustments shall be provided by variable value components, which are adjustable, by the use of simple means. The calibration by substitution of selected components or parts is unacceptable unless specifically approved. The calibration adjustments, wherever possible, shall be
8、accessible without removal of the instrument case or modules. The calibration interval shall be a period of one year or greater, based on an operating time of 2000 hours per year. 2.6 Electrical Power Sources and Connections. The equipment shall operate from nominal commercial, military, and shipboa
9、rd power source of 120Vrms or 240Vrms single-phase AC ( 10 %) at line frequencies of 50 Hz and 60 Hz ( 5 %) as specified in MIL-PRF-28800. 2.7 Performance Characteristics. 2.7.1 General Description. The FM/AM Modulation meter shall be able to analyze a minimum frequency of 150 kHz up to and includin
10、g the frequency of 1.3 GHz. The FM/AM Modulation Meter shall come fully calibrated so that it meets or exceeds all performance and testing requirements in a laboratory environment. 2.7.2 Radio Frequency (RF) Input. 2.7.2.1 Carrier Frequency Range. The FM/AM Modulation Meter shall analyze a carrier f
11、requency range from 150 kHz to 1.3 GHz. For phase modulation the carrier frequency shall be from 10 MHz to 1.3 GHz. 2.7.2.2 The FM/AM Modulation Meter shall have automatic or manual front panel tuning. 2.7.2.3 Maximum Input. The FM/AM Modulation Meter shall be able to withstand an application of 35
12、Vrms (+25 dBm with a SWR less than 4 at frequencies from 150 kHz to 1.3 GHz) or 40 V DC without any harmful effects. 2.7.2.4 Input Impedance. The FM/AM Modulation Meter shall have the input impedance of 50 ohms nominal with an N type connector used. 2.8 Frequency Modulation (FM). 2.8.1 Amplitude Mod
13、ule (AM) Rejection shall typically be less than 20 Hz peak deviation measured in a 50 Hz to 3 kHz bandwidth for 50 % AM at 400 Hz or 1 kHz rate. 2.8.2 Residual FM shall be less than 8 Hz at 1.3 GHz and decreases linearly with frequency to less than 1 Hz at 100 MHz and below. 2.8.3 FM Deviation Range
14、. Carrier frequencies 150 kHz to 5.5 MHz must have a maximum deviation of 40 kHz at rate of 30 Hz to 10 kHz. Carrier frequencies of 10 MHz to 1.3 GHz must have a maximum deviation of 400 kHz at rates of 30 Hz to 200 kHz. Provided by IHSNot for ResaleNo reproduction or networking permitted without li
15、cense from IHS-,-,-A-A-59418 3For clarification purposes, the specifications are. Maximum Deviation Carrier Frequency Rates 40 kHz peak 150 kHz to 5.5 MHz 30 Hz to 10 kHz 400 kHz peak 10 MHz to 1.3 GHz 30 Hz to 200 kHz 2.8.3.1 Accuracy of Frequency Modulated Reading on the following ranges must be:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA594182003METERMODULATION150KHZTO13GHZ 调制 150 千赫 13 吉赫 PDF

链接地址:http://www.mydoc123.com/p-427096.html