AASHTO T 48-2017 Standard Method of Test for Flash and Fire Points by Cleveland Open Cup.pdf
《AASHTO T 48-2017 Standard Method of Test for Flash and Fire Points by Cleveland Open Cup.pdf》由会员分享,可在线阅读,更多相关《AASHTO T 48-2017 Standard Method of Test for Flash and Fire Points by Cleveland Open Cup.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup AASHTO Designation: T 48-171Technical Section: 2b, Liquid Asphalt Release: Group 3 (August 2017) American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C
2、. 20001 TS-2b T 48-1 AASHTO Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup AASHTO Designation: T 48-171Technical Section: 2b, Liquid Asphalt Release: Group 3 (August 2017) 1. SCOPE 1.1. This method covers the procedure for the determination of flash point of asphalt
3、binder by the Cleveland open-cup apparatus. 1.2. This test method is applicable to asphalt binder with flash point between 80C (175F) and 400C (750F). Note 1Specifications commonly designate the Tag Open-Cup method (T 79) for asphalt binders and cutback asphalts having flash points below 93C (200F).
4、 1.3. The values stated in SI units are to be regarded as the standard. 1.4. This test may involve hazardous materials, operations, and equipment. This test does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user to establish appropriate s
5、afety and health practices and determine the applicability of regulatory limitations prior to use. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: R 18, Establishing and Implementing a Quality Management System for Construction Materials Testing Laboratories R 66, Sampling Asphalt Materials T 79, Fla
6、sh Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93C (200F) 2.2. ASTM Standards: C670, Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials E1, Standard Specification for ASTM Liquid-in-Glass Thermometers E
7、220, Standard Test Method for Calibration of Thermocouples By Comparison Techniques E644, Standard Test Methods for Testing Industrial Resistance Thermometers 2017 by the American Association of State Highway and Transportation Officials. All rights reserved. Duplication is a violation of applicable
8、 law.TS-2b T 48-2 AASHTO 2.3. NCHRP Report: D.W. Christensen, and R. F. Bonaquist. National Cooperative Highway Research Program Report 530: Evaluation of Indirect Tensile Test (IDT) Procedures for Low-Temperature Performance of Hot Mix Asphalt. NCHRP, Transportation Research Board, Washington, DC,
9、2004. 3. SUMMARY OF TEST METHOD 3.1. The sample is placed in the tester and heated rapidly to begin with then at a slow rate. A small test flame is passed at a uniform rate in a level plane across the cup at specified intervals. The flash point is the lowest temperature at which application of the t
10、est flame causes the vapor at the surface of the liquid to flash. 4. APPARATUS 4.1. Cleveland Open-Cup TesterConsisting of the following parts; the parts must conform to t he dimensions shown and have the additional characteristics as noted. (See Figure 1.) The Cleveland open-cup tester may be manua
11、l or automated. If automated, the flash point instrument shall perform the test in accordance with Section 7. Figure 1Cleveland Open-Cup Apparatus ABDEFThermometerHeating PlateDiameterof OrificeGasorElectricHeatSourceGasSupplyDiameterof MetalBeadCDiameterof TubingOpen Cupwith Asphalt 2017 by the Ame
12、rican Association of State Highway and Transportation Officials. All rights reserved. Duplication is a violation of applicable law.TS-2b T 48-3 AASHTO Millimeters Inches Min Max Min Max ADiameter 3.8 5.4 0.15 0.21 BRadius 152 nominal 6 nominal COutside Diameter 1.6 5.0 0.06 0.20 D 5.0 0.20 E 6.4, ap
13、proximately 0.25, approximately FInside Diameter 0.8 nominal 0.031 nominal Figure 1Cleveland Open-Cup Apparatus (continued) 4.1.1. Test CupCup made of brass or other metal of similar conductivity conforming to Figure 2. The cup may be equipped with a handle. Millimeters Inches Min Max Min Max A 67.5
14、 69 2.658 2.717 B 62.5 64.0 2.46 2.52 C 2.8 3.6 0.11 0.14 DRadius 4, approximately 0.16, approximately E 32.5 34 1.280 1.339 F 9 10 0.354 0.394 G 1.8 3.4 0.07 0.13 H 2.8 3.6 0.11 0.14 I 97 101 3.8 4.0 Figure 2Cleveland Open Cup ACFFillingMarkEIBGDH45 2017 by the American Association of State Highway
15、 and Transportation Officials. All rights reserved. Duplication is a violation of applicable law.TS-2b T 48-4 AASHTO 4.1.2. Heating PlatePlate that ensures the heat is evenly distributed over the bottom of the test cup and that extraneous heating to other surfaces is minimized. See Figure 3 for plat
16、e dimensions. Millimeters Inches Min Max Min Max A 6.4, nominal 0.25, nominal B 0.5 1.0 0.020 0.039 C 6.4, nominal 0.25, nominal DDiameter 54.5 56.5 2.15 2.22 EDiameter 69.5 70.5 2.736 2.776 FDiameter 150, nominal 6, nominal Figure 3Heating Plate 4.1.3. Heat SourceGas burner or electric heater cente
17、red under the opening of the heating plate with no local overheating. If using a gas burner, protect the flame from drafts using suitable shields that do not project above the top of the heating plate. 4.1.4. Thermometer HolderSupplied with the tester; it shall support the thermometer firmly in a ve
18、rtical position. 4.1.5. Heating Plate HolderSupport to hold the heating plate level and steady. 4.1.6. Ignition Source ApplicatorThe device for applying the test flame; may be of any suitable design, but the tip shall be 1.6 to 5.0 mm (0.06 to 0.20 in.) in diameter at the end and the orifice shall h
19、ave an approximate diameter of 0.8 mm (0.031 in.). The device for applying the test flame shall be so mounted to permit automatic duplication of the sweep of the test flame, the radius of swing being not less than 150 mm (6 in.) and the center of the orifice moving in a plane not more than 2.5 mm (0
20、.10 in.) above the cup. A bead having a diameter of 3.8 to 5.4 mm (0.15 to 0.21 in.) shall be mounted in a convenient position on the apparatus so the size of the test flame can be compared to it. 4.2. ThermometerAn ASTM 11C (11F) thermometer as prescribed in ASTM E1 with an accuracy of 0.2C (0.5F).
21、 The thermometer shall be calibrated according to the requirements specified in R 18. This thermometer shall be used to make all temperature measurements required by this method. FMetalThermalInsulationACEDB 2017 by the American Association of State Highway and Transportation Officials. All rights r
22、eserved. Duplication is a violation of applicable law.TS-2b T 48-5 AASHTO 4.2.1. The test thermometer may be replaced with an alternative thermometric device, provided the following requirements are met: 4.2.1.1. The thermometric device shall be mounted in the same position as the test thermometer i
23、t replaces. 4.2.1.2. The thermometric device shall 1) have a maximum scale error no greater than that of the test thermometer it replaces, 2) be capable of indicating temperature within 0.1C (0.2F), and 3) have the same temperature response. 4.2.1.3. The thermometric device shall be standardized at
24、the interval specified in R 18. Guidance for performing the standardization is given in ASTM E220 or E644. 4.3. Filling Level Gauge (optional)A device to aid in the proper adjustment of the sample level in the cup. It may be made of suitable metal with at least one projection, but preferably two, fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT482017STANDARDMETHODOFTESTFORFLASHANDFIREPOINTSBYCLEVELANDOPENCUPPDF

链接地址:http://www.mydoc123.com/p-418337.html