UL 61010-1 (ND)-2012 National Differences For UL 61010-1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use - Part 1 General Requirements (Edit.pdf
《UL 61010-1 (ND)-2012 National Differences For UL 61010-1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use - Part 1 General Requirements (Edit.pdf》由会员分享,可在线阅读,更多相关《UL 61010-1 (ND)-2012 National Differences For UL 61010-1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use - Part 1 General Requirements (Edit.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 61010-1Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use -Part 1: General RequirementsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
2、 FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 61010-1Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1:General RequirementsEdition: 3Edition Date: May 11, 2012This revision to ANSI/UL 61010-1 is being issued
3、 to include the following changes inrequirements:Editorial Corrections to match IEC Standard for Clause 3.6.12Revisions to 6.7.2.2.1, 6.7.2.2.4, 6.7.3.4.1, 6.7.3.4.4, 6.8.3.1, 9.6.1, K.1.3.1, K.1.3.4, K.2.4.1,K.2.4.4, and K.3.2This document provides a single listing of the National Differences inclu
4、ded in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides thi
5、s standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss
6、 of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pric
7、epaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting
8、 from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2015 Underwriters Laboratories Inc.JULY 15, 2015NATIONAL DIFFERENCES FOR UL UL 61010-12UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION W
9、ITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additi
10、onally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety p
11、ractices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standa
12、rd is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thef
13、ollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Dele
14、tion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the r
15、eplacement of an entire clause,subclause, table, figure, or annex of the base IEC text.JULY 15, 2015 NATIONAL DIFFERENCES FOR UL UL 61010-1 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1.4DV DR Addition of the followi
16、ng referencing the National Electrical Code and theCanadian Electrical Code:This standard applies to equipment:a) To be employed in accordance with ANSI/NFPA 70, National Electrical Code(NEC);b) Designed to comply with the general requirements of CAN/CSA C22.2 No. 0and to be installed in accordance
17、with the Canadian Electrical Code (CEC), Part I,CSA C22.1; orc) Both (a) and (b).2DV DC Addition of the following:ANSI/NFPA 70,National Electrical CodeANSI/UL 94,Tests for Flammability of Plastic Materials for Parts in Devices and AppliancesANSI/UL 498,Attachment Plugs and ReceptaclesANSI/UL 746C,Po
18、lymeric Materials Use in Electrical Equipment EvaluationsANSI/UL 817,Cord Sets and Power Supply CordsANSI/UL 1310,Class 2 Power UnitsANSI/UL 60950-1,Information Technology Equipment - Safety - Part 1: General RequirementsCSA C22.1,Canadian Electrical Code, Part ICSA C22.2 No. 0,General Requirements
19、- Canadian Electrical Code, Part IICAN/CSA C22.2 No. 0.17,Evaluation of Properties of Polymeric MaterialsJULY 15, 2015NATIONAL DIFFERENCES FOR UL UL 61010-14UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCAN/CSA C22.2 No. 0.4,Bonding of elect
20、rical equipmentCSA C22.2 No. 21,Cord Sets and Power Supply CordsCSA C22.2 No. 42,General Use Receptacles, Attachment Plugs, and Similar Wiring DevicesCSA C22.2 No. 182.1,Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve TypeCSA C22.2 No. 182.2,Industrial Locking Type, Special Use Attach
21、ment Plugs, Receptacles, and ConnectorsCSA C22.2 No. 182.3,Special Use Attachment Plugs, Receptacles, and ConnectorsCAN/CSA C22.2 No. 223,Power Supplies With Extra-Low Voltage Class 2 OutputsCAN/CSA C22.2 No. 60950-1,Information Technology Equipment - Safety - Part 1: General Requirements3.6.12DV D2
22、 Modification to replace with the following:CREEPAGE DISTANCE : shortest distance along the surface of a solid insulating material betweentwo conductive partsIEC 60050-151:2001, 151-15-506.3.1DV D2 Modification by replacing item (a) with the following:The a.c. voltage levels are 30 V r.m.s., 42,4 V
23、peak and the d.c. voltage level is 60 V. Forequipment intended to be used in WET LOCATIONS, the a.c. voltage levels are 16 V r.m.s., 22,6V peak and the d.c voltage level is 35 V d.c.6.3.2DV D2 Modification by replacing item (a) with the following:The a.c. voltage levels are 50 V r.m.s., 70 V peak an
24、d the d.c. voltage level is 120 V. Forequipment intended to be used in WET LOCATIONS, the a.c. voltage levels are 33 V r.m.s., 46,7V peak and the d.c voltage level is 70 V d.c. For voltages of short duration, the durationversus voltage levels are those of Figure 2DV, measured across a 50 k resistor.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL610101ND2012NATIONALDIFFERENCESFORUL610101SAFETYREQUIREMENTSFORELECTRICALEQUIPMENTFORMEASUREMENTCONTROLANDLABORATORYUSEPART1GENERALREQUIREMENTSEDITPDF

链接地址:http://www.mydoc123.com/p-1068637.html