《UL 60079-15 (ND)-2013 National Differences For Explosive atmospheres C Part 15 Equipment protection by type of protection Fourth Edition Reprint with Revisions Through and Includin.pdf》由会员分享,可在线阅读,更多相关《UL 60079-15 (ND)-2013 National Differences For Explosive atmospheres C Part 15 Equipment protection by type of protection Fourth Edition Reprint with Revisions Through and Includin.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60079-15Explosive atmospheres - Part 15: Equipment protection by type of protection nUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITH
2、OUT PERMISSION FROM ULNational Differences ForUL 60079-15Explosive atmospheres - Part 15: Equipment protection by type of protection nEdition: 4Edition Date: February 15, 2013This revision to ANSI/UL 60079-15, the Standard for Safety for Explosive Atmospheres Part 15:Equipment Protection by Type of
3、Protection n, (Edition 4.0, Issued by the IEC January 2010)is issued to note the effective date information which was first published February 15, 2013 witheffective date to be determined. It also contains editorial corrections to 24.3 to add “Class I,Zone 2, A” prefix to the marking examples.As not
4、ed in the Commitment for Amendments statement located on the back side of the titlepage, UL and ISA are committed to updating this bi-national standard jointly. However, therevision pages dated August 2, 2013 will not be issued by ISA as revision pages but asan update to their standard.This document
5、 provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording
6、, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidenta
7、l, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no e
8、vent shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim
9、, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright Underwriters Laboratories Inc.AUGUST 2, 2013NATIONAL DIFFERENCES FOR UL UL 60079-152UL COPYRIGHTED MATERIAL
10、 NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to ide
11、ntify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and user
12、s of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards a
13、nd will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of wh
14、at the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant
15、 to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as thead
16、dition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.AUGUST 2, 2013 NATIONAL DIFFERENCES FOR UL UL 60079-15 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FR
17、OM ULNational Differences1DV.1 DR Modification of Clause 1, first paragraph as follows:1DV.1.1 Replace “part of IEC 60079” with “standard”.1DV.2 DR Modification of Clause 1, second paragraph as follows:1DV.2.1 Replace “part of IEC 60079” with “standard”.Table 1DV DR Modification of Table 1 to replac
18、e with the following:Table 1DV Relationship of this part to IEC 60079-0Clause of IEC 60079-0 IEC 60079-0 clause application to IEC 60079-15Ed. 5.0 (2009)Ed. 6.01(futureedition)Clause / Subclause title ProtectedsparkingNon sparkingRestrictedbreathing(informative) (informative) (normative) nC nA nR4 4
19、 Equipment grouping Applies Applies Applies 4.1 Group I Excluded Excluded Excluded4.2 4.2 Group II Applies Applies Applies4.3 4.3 Group III Excluded Excluded Excluded4.4 4.4 Equipment for a particularexplosive atmosphereApplies Applies Applies5.1 5.1 Environmental influences Applies Applies Applies5
20、.1.1 5.1.1 Ambient temperature Applies Applies Applies5.1.2 5.1.2 External source of heating orcoolingApplies Applies Applies5.2 5.2 Service temperature Applies Applies Applies5.3.1 5.3.1 Determination of maximumsurface temperatureApplies Applies Applies 5.3.2.1 Group I electrical equipment Excluded
21、 Excluded Excluded5.3.2.2 5.3.2.2 Group II electrical equipment Applies Applies Applies5.3.2.3 5.3.2.3 Group III electrical equipment Excluded Excluded Excluded5.3.3 5.3.3 Small component temperaturefor Group I and Group IIelectrical equipmentApplies Applies Excluded6.1 6.1 General Applies Applies A
22、pplies6.2 6.2 Mechanical strength Applies Applies Applies6.3 6.3 Opening times Excluded Excluded Applies6.4 6.4 Circulating currents Applies Applies Applies6.5 6.5 Gasket retention Applies Applies Applies6.6 6.6 Electromagnetic and ultrasonicradiating equipmentApplies Applies Applies7.1.1 7.1.1 Appl
23、icability Applies Applies Applies7.1.2 7.1.2 Specification of materials Applies Applies Applies1Under considerationAUGUST 2, 2013NATIONAL DIFFERENCES FOR UL UL 60079-154Table 1DV Relationship of this part to IEC 60079-0 Continued on Next PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
24、CTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 1DV Relationship of this part to IEC 60079-0 ContinuedClause of IEC 60079-0 IEC 60079-0 clause application to IEC 60079-15Ed. 5.0 (2009)Ed. 6.01(futureedition)Clause / Subclause title ProtectedsparkingNon sparkingRestrictedbreathing(informative) (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6007915ND2013NATIONALDIFFERENCESFOREXPLOSIVEATMOSPHERESCPART15EQUIPMENTPROTECTIONBYTYPEOFPROTECTIONFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINPDF

链接地址:http://www.mydoc123.com/p-1068351.html