UL 325 CRD-2014 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference New 32 5A Subject Unattended Operation control acces.pdf
《UL 325 CRD-2014 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference New 32 5A Subject Unattended Operation control acces.pdf》由会员分享,可在线阅读,更多相关《UL 325 CRD-2014 UL Standard for Safety Door Drapery Gate Louver and Window Operators and Systems - Section Paragraph Reference New 32 5A Subject Unattended Operation control acces.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): FDDRStandard Number: UL 325Standard Title: Standard for Door, Drapery, Gate, Louver, and Window Operatorsand SystemsEdition Date: October 14, 2013Edition Num
3、ber: 6Section / Paragraph Reference: New 32.5ASubject: Unattended Operation control accessoriesDECISION:32.5A Unattended operation control accessory32.5A.1 General32.5A.1.1 A residential garage door operator control accessory shall be permitted to be supplied separatefrom the operator, and per 3.23
4、may permit unattended operation to close a garage door, provided thecontrol accessory complies with the additional requirements of 32.5A.2 - 32.5A.6.Exception: Unattended operation shall not be permitted on one-piece garage doors or swinging garagedoors. A control accessory that has an unattended op
5、eration close feature shall identify that theunattended operation closing feature is only permitted to be enabled when installed with a sectional doorby complying with:a) The installation instructions of 58.4.2;b) The markings of 59.8; andc) The carton markings of 61.3.2.32.5A.2 Operator system32.5A
6、.2.1 The control accessory shall require one or more intentional actions to enable unattendedoperation to function when connected to an operator system, such as setting a power head switch orwall-control switch. For an accessory requiring installation and set-up in order to enable unattendedoperatio
7、n, the installation and set-up may be considered satisfying this requirement.32.5A.3 Alarm signal32.5A.3.1 The control accessory alone or in combination with the operator system shall provide an audibleand visual alarm signal.32.5A.3.2 The alarm shall signal for a minimum of 5 seconds before any una
8、ttended door movement.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL32.5A.3.3 The audible signal shall be heard within the confines of a garage. The audio alarm signals forthe alarm specified in 32.5A.3.1 shall be generated by devices such a
9、s bells, horns, sirens, or buzzers.The signal shall have a frequency in the range of 700 to 3400 Hz, either a cycle of the sound levelpulsations of 4 to 5 per second or one continuous tone, a sound level at least 45 dB 10 ft (305 cm) in frontof the device over the voltage range of operation.32.5A.3.
10、4 The visual alarm signal of 32.5A.3.1 shall be visible within the confines of a garage using aflashing light of at least 40 watt incandescent or 360 lumens.32.5A.3.5 When the visual alarm or the audio alarm, or both, are external to the control accessory andare not part of main operator unit, the c
11、ontrol accessory shall monitor for the connection of and properoperation of both the visual and audible alarms, prior to initiating door travel.32.5A.4 Controls32.5A.4.1 During the pre-motion signaling period defined in 32.5A.3.2, activation of any user door control(i.e. wall control, wireless remot
12、e, keypad) shall prevent the pending unattended door movement. Doormovement resulting from activation of a user door control is not prohibited.32.5A.4.2 Upon activation of a user door control during unattended door movement:a) the operator shall function in the same manner as if the control accessor
13、y were not present;b) the control accessory shall not interfere with, override, or alter the normal operation of theoperator; andc) the door shall stop, and may reverse the door on the closing cycle. On the opening cycle,activation of a user door control shall stop the door but not reverse it.32.5A.
14、5 Entrapment protection32.5A.5.1 The control accessory shall not interfere with, override, or alter any entrapment protectionfeatures of the operator or system per 32.2 and 32.3.A control accessory that only provides a momentary signal (wired or wireless) to start the door isconsidered to comply wit
15、h this requirement.32.5A.5.2 If an unattended door travelling in the closing direction is stopped and reversed by anentrapment protection device, the control accessory alone or in combination with the operator system shallbe permitted one additional unattended operation attempt to close the door.32.
16、5A.5.3 After two attempts per 32.5A.5.2, the control accessory alone or in combination with theoperator system shall suspend unattended operation. The control accessory alone or in combination withthe operator system shall require a renewed, intended input, via door control, prior to re-enablingunat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL325CRD2014ULSTANDARDFORSAFETYDOORDRAPERYGATELOUVERANDWINDOWOPERATORSANDSYSTEMSSECTIONPARAGRAPHREFERENCENEW325ASUBJECTUNATTENDEDOPERATIONCONTROLACCESPDF

链接地址:http://www.mydoc123.com/p-1068064.html