UL 1450 CRD-2018 UL Standard for Safety Motor-Operated Air Compressors Vacuum Pumps and Painting Equipment - Section Paragraph Reference 46 46 1 8 Subject Clarifying normal load r.pdf
《UL 1450 CRD-2018 UL Standard for Safety Motor-Operated Air Compressors Vacuum Pumps and Painting Equipment - Section Paragraph Reference 46 46 1 8 Subject Clarifying normal load r.pdf》由会员分享,可在线阅读,更多相关《UL 1450 CRD-2018 UL Standard for Safety Motor-Operated Air Compressors Vacuum Pumps and Painting Equipment - Section Paragraph Reference 46 46 1 8 Subject Clarifying normal load r.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): QDGSStandard Number: UL 1450Standard Title: Standard for Motor-Operated Air Compressors, Vacuum Pumps, andPainting EquipmentEdition Date: May 5, 2010Edition Number: 4Section / Paragraph Reference: 46,
3、 46.1.8Subject: Clarifying normal load run time for commercial inflatorsDECISION:46 Temperature Test46.1.8 An inflator default duty cycle rate is 15 min on, 5 min off.Exception: Commercial inflators employing a timer circuit that positively and reliably limits the length oftime the product can be op
4、erate shall be operated for the maximum preset duration of operation, followedby a period of 5 min “off”. Following the “off” period, normal load is applied again. This mode of cyclingshall be repeated five times. Temperatures shall be measured at the end of the 5th cycle of operation.RATIONALE FOR
5、DECISION:Commercial inflators that employ timer circuits may not able to operate for 15 min without bypassing thetimer circuits provided with the inflator. Therefore, this Certification Requirement Decision provides anexception to Clause 46.1.8, allowing commercial inflators provided with a reliable
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1450CRD2018ULSTANDARDFORSAFETYMOTOROPERATEDAIRCOMPRESSORSVACUUMPUMPSANDPAINTINGEQUIPMENTSECTIONPARAGRAPHREFERENCE464618SUBJECTCLARIFYINGNORMALLOADRPDF

链接地址:http://www.mydoc123.com/p-1067493.html