NEMA WC 56-1986 3 0 kHz Insulation Continuity Proof Testing of Wire and Cable《电线及电缆3 0 kHz绝缘持续性证明试验》.pdf
《NEMA WC 56-1986 3 0 kHz Insulation Continuity Proof Testing of Wire and Cable《电线及电缆3 0 kHz绝缘持续性证明试验》.pdf》由会员分享,可在线阅读,更多相关《NEMA WC 56-1986 3 0 kHz Insulation Continuity Proof Testing of Wire and Cable《电线及电缆3 0 kHz绝缘持续性证明试验》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA WC 56-1986 (R2012)3.0 kHz Insulation Continuity Proof Testing of Wire and Cable Copyright 2013 by National Electrical Manufacturers Association NEMA WC 56-1986 (R1993, R2000, R2005, R2012) 3.0 kHz Insulation Continuity Proof
2、 Testing of Wire and Cable Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, Virginia 22209 www.nema.org Copyright 2013 by the National Electrical Manufacturers Association. All rights including translation into other languages, reserved under the Universal
3、Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. WC 56-1986 (R1993, R2000, R2005, R2012) Page ii Copyright 2013 by National Electrical Manufacturers Association NOTICE AND DISCLAIMER The inform
4、ation in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of th
5、is document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of
6、persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of
7、any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting
8、from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfil
9、l any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or oth
10、er services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining
11、 the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor do
12、es it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this docum
13、ent shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. WC 56-1986 (R1993, R2000, R2005, R2012) Page iii Copyright 2013 by National Electrical Manufacturers Association FOREWORD This standards publication has been prepared to delineate the b
14、asic requirements for spark testing apparatus utilizing a 3 kHz nominal frequency. It is intended as a substitute or an alternative to conventional spark testing at an industrial frequency. The use of an elevated frequency will allow a reduction in the electrode length while exposing the wire or cab
15、le to a suitable number of wave crests. Performance criteria have been included which will stipulate minimum sensitivities for the equipment. Underwriters Laboratories has recognized 3 kHz spark test for testing of wire or cable. The NEMA High Performance Wire and Cable Section prepared this test pr
16、ocedure. Comments or proposed revisions are welcomed and should be submitted to: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 N. 17thStreet Rosslyn, VA 22209 At the time of the reaffirmation of this standard in 2012, the NEMA High Performance Wire and Cabl
17、e Section comprised the following member companies: AFC Cable Systems, Inc. a part of Atkore International New Bedford, MA Apical Division, Kaneka Texas Corporation Pasadena, TX Belden St. Louis, MO Cable USA LLC Naples, FL Champlain Cable Corporation Colchester, VT Coleman Cable, Inc. Waukegan, IL
18、Freeport-McMoRan Copper and Gold Phoenix, AZ General Cable Highland Heights, KY Harbour Industries LLC Shelburne, VT IWG High Performance Conductors Inman, SC Leoni Wire, Inc. Chicopee, MA Marmon Innovation and Technology Group Seymour, CT Prestolite Wire and Cable Southfield, MI Quirk Wire Company,
19、 Inc. West Brookfield, MA Radix Wire Company Euclid, OH RSCC Wire and Cable Group East Granby, CT Rubadue Wire Co., Inc. Greeley, CO Southwire Company Carrolton, GA TE Connectivity Ltd., a Tyco Electronics Corporation Menlo Park, CA The Monroe Cable Company, Inc. Middletown, NY The Okonite Company R
20、amsey, NJ WC 56-1986 (R1993, R2000, R2005, R2012) Page iv Copyright 2013 by National Electrical Manufacturers Association WC 56-1986 (R1993, R2000, R2005, R2012) Page v Copyright 2013 by National Electrical Manufacturers Association TABLE OF CONTENTS FOREWARDiii Section 1 TEST EQUIPMENT .2 1.1 ELECT
21、RODE2 1.1.1 Electrode Length2 1.1.2 Use of Electrode.2 1.2 VOLTAGE SHAPE.2 1.3 VOLTAGE FREQUENCY.2 1.4 VOLTMETER3 1.5 REGULATION 3 1.6 FAILURE DETECTION CIRCUIT 3 1.7 SAFETY OF EQUIPMENT AND SAFE USE OF EQUIPMENT.5 Section 2 TEST PROCEDURE. 6 2.1 SET-UP. 6 2.1.1 Voltage 6 2.1.1.1 Maximum Voltage. 6
22、2.1.2 Frequency 6 2.1.3 Line Speed6 2.1.3.1 Maximum.7 2.1.3.2 Minimum7 2.2 FAULT IDENTIFICATION 7 2.3 CALIBRATION AND CREST FACTOR7 2.4 VENTILATION OF WORK AREA 7 WC 56-1986 (R1993, R2000, R2005, R2012) Page 1 Copyright 2013 by National Electrical Manufacturers Association SCOPE This standard covers
23、 a general procedure for continuous voltage proof testing of wire and cable. It is intended to apply primarily to the final inspection of wire or cable for the purpose of finding and eliminating defects prior to shipment or before use. The method can also be used to eliminate defects at an early sta
24、ge of manufacturing, i.e., for wire or cable to be used in multiconductor cables or jacketed constructions. Because of possible damage in handling, damage caused by repeated testing, and variations in test parameters, comparison between producers and consumers test results are not significant. WC 56
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAWC56198630KHZINSULATIONCONTINUITYPROOFTESTINGOFWIREANDCABLE 电线 电缆 30 KHZ 绝缘 持续性 证明 试验 PDF

链接地址:http://www.mydoc123.com/p-994473.html