NAVY UFGS-09 67 23 16-2010 FUEL RESISTIVE RESINOUS FLOORING 5-COAT SYSTEM《5涂层系统阻燃树脂地板材料》.pdf
《NAVY UFGS-09 67 23 16-2010 FUEL RESISTIVE RESINOUS FLOORING 5-COAT SYSTEM《5涂层系统阻燃树脂地板材料》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-09 67 23 16-2010 FUEL RESISTIVE RESINOUS FLOORING 5-COAT SYSTEM《5涂层系统阻燃树脂地板材料》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 67 23.16 (August 2010)-Preparing Activity: NAVFAC SupersedingUFGS-09 67 23.16 (February 2010)UFGS-09 67 23.16 (August 2009)UFGS-09 67 23.16 (August 2008)UFGS-09 62 50.12 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL
2、dated July 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 67 23.16FUEL RESISTIVE RESINOUS FLOORING, 5-COAT SYSTEM08/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Test Reports1.3.1.1 Joint Sealant1.3.1.2 Epoxy Mortar Flooring System1.3.1.3 Primer1.3.1.4 Grout
3、Coat1.3.1.5 Urethane Topcoat1.3.1.6 Daily Inspection Report1.3.2 Certificates1.3.2.1 Work Plan1.3.2.2 Flooring System Applicator Qualifications1.3.2.3 Joint Sealant1.3.2.4 Epoxy Mortar Flooring System1.3.2.5 Warranty1.3.3 Manufacturers Instructions1.3.3.1 Joint Sealant1.3.3.2 Epoxy Mortar Flooring S
4、ystem1.3.3.3 Water-Based Alkaline Degreaser1.4 DELIVERY, STORAGE, AND HANDLING1.5 COATING HAZARDS1.6 JOB SITE REFERENCES1.7 PATCH TEST DEMONSTRATIONPART 2 PRODUCTS2.1 JOINT SEALANT2.2 EPOXY MORTAR FLOORING SYSTEM2.2.1 Primer Coat2.2.2 Grout CoatSECTION 09 67 23.16 Page 1Provided by IHSNot for Resale
5、No reproduction or networking permitted without license from IHS-,-,-2.2.3 Urethane Topcoat2.3 WHITE ALUMINUM OXIDE NON-SKID GRIT2.4 PREAPPROVED MATERIALSPART 3 EXECUTION3.1 COATING SAMPLE COLLECTION3.2 TILE AND TILE ADHESIVE REMOVAL3.3 JOINT MATERIAL REMOVAL, RE-SAW CUTTING, CRACK CHASING3.4 DEGREA
6、SING3.5 COATING SYSTEM REMOVAL3.6 SURFACE PREPARATION3.6.1 CMU Surface Preparation3.7 COVE STRIP INSTALLATION3.8 KEY-IN TERMINATIONS3.9 CRACK REPAIRS3.9.1 Install Bondbreaker3.9.2 Repair Cracks3.10 PRE-APPLICATION TESTING FOR CONTAMINATION3.11 COATING APPLICATION3.11.1 Isolation (Expansion) and Cons
7、truction Joint Treatment3.11.2 Contraction Joint Treatment3.11.3 Primer Application3.11.4 Epoxy Mortar Application3.11.5 Primer Application to CMU Walls3.11.6 Epoxy Mortar Application to CMU Walls3.11.7 Grout Coat Application3.11.8 Grout Coat Sanding3.11.9 Saw Cutting and Sealing Joints3.11.9.1 Saw
8、Cut Contraction Joints3.11.9.2 Saw Cut Isolation (Expansion) and Construction Joints3.11.9.3 Install Backer Rod3.11.9.4 Joint Sealant Application3.11.10 Application of Topcoats3.11.10.1 Non-Skid Grit Broadcast3.11.10.2 Grout Coat Cleaning3.11.10.3 First Topcoat3.11.10.4 Second topcoat3.11.10.5 Walkw
9、ay Stripes3.12 CURING3.13 FIELD TESTS AND INSPECTION3.13.1 Coating Inspector3.13.2 Inspection3.13.2.1 Daily Inspection Report3.13.2.2 Inspection Logbook3.13.2.3 Inspection Equipment3.13.3 Adhesion Testing3.14 Final Cleanup- End of Section Table of Contents -SECTION 09 67 23.16 Page 2Provided by IHSN
10、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 67 23.16 (August 2010)-Preparing Activity: NAVFAC SupersedingUFGS-09 67 23.16 (February 2010)UFGS-09 67 23.16 (August 2009)UFGS-09 67 23.16 (August 2008)UFGS-09 62 50.12 (April 2
11、006) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 09 67 23.16FUEL RESISTIVE RESINOUS FLOORING, 5-COAT SYSTEM08/10*NOTE: This guide specification covers the requirements for a five-coat, epoxy mortar flooring system with reflective urethane topc
12、oats, slip resistance, and joint work.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, wheth
13、er or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended cha
14、nges to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: The epoxy mortar flooring system is appropriate for use in: aircraft maintenance hangars, equipment maintenance shops, jet engine test cells, and all other industrial floors where resistance to impact, abrasion, and fuel is
15、 required. Installation costs: $5.00 to $10.00 per 0.1 square meters square foot. Nominal thickness: 6.25 mm 1/4 inch. Benefits: Tolerates high Moisture Vapor Emission (MVE) rates, produces a level surface over coarse concrete, high impact resistance, good chemical resistance, and may provide a suit
16、able topcoat base for more than 10 years service. Can be rejuvenated by replacing urethane topcoats, and SECTION 09 67 23.16 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-non-skid, only. Approximate service life: Urethane topcoating with non-
17、skid grit at three or more years. The flooring system is neither conductive nor Electro-Static Dissipative (ESD), however, either formulation is easily designed upon request. This specification is not for use in overcoating existing sound coating systems.*NOTE: Prior to the flooring systems installa
18、tion, a concrete condition assessment in accordance with the Naval Facilities Engineering Service Centers (NFESC) Users Guide (UG)-2036-SHR is highly recommended. The condition assessment is designed to identify problem floors and eliminate premature flooring failures produced by: 1) Coating concret
19、e with low surface strength, 2) coating concrete with high surface contamination levels (oils, fuels, fats, waxes, etc.), and 3) coating concrete with a high Moisture Vapor Emission (MVE) rate. The thin film flooring system is suitable for application to: A) “Smooth“ or “Coarse“ concrete surface tex
20、tures, B) concrete with a MVE rate no more than 254 micrograms moisture per second, square meter 4.5 pounds moisture per 24 hours, 1000 square feet (ASTM F 1869), C) concrete with surface strength greater than 1.34 MPa 200 psi (ASTM D 4541), and D) concrete with fuel/oil contamination to a depth no
21、more than 6.25 mm 1/4 inch.*NOTE: If a concrete floor has a Moisture Vapor Emission (MVE) rate more than 254 micrograms moisture per second, square meter 4.5 pounds moisture per 24 hours, 1000 square feet (ASTM F 1869), apply a layered Moisture Reducing System (MRS) prior to the epoxy mortar floorin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS096723162010FUELRESISTIVERESINOUSFLOORING5COATSYSTEM5 涂层 系统 阻燃 树脂 地板 材料 PDF

链接地址:http://www.mydoc123.com/p-984761.html