《FORD WSB-M1L134-A1-2003 CABLE PRIMARY LOW TENSION 85 VINYL INSULATED-THIN WALL TO BE USED WITH FORD WSS-M99P1111-A 《薄护皮型乙烯基绝缘的85℃低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD WSB-M1L134-A1-2003 CABLE PRIMARY LOW TENSION 85 VINYL INSULATED-THIN WALL TO BE USED WITH FORD WSS-M99P1111-A 《薄护皮型乙烯基绝缘的85℃低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 0812 Revised Para 3.0 inserted; Para 3.1, 3.2, 3.6, 4 deleted 1995 03 31 Activated J.M. Showalter Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 1 of 6 CABLE, PRIMARY LOW TENSION, 85 C, VINYL WSB-M1L13
2、4-A1 INSULATED-THIN WALL 1. SCOPE The material defined by this specification is a low tension stranded cable, vinyl insulated with a non-coated conductor. The cable is similar to SAE J1128 (General Purpose-Thermoplastic Insulated) but with a reduced insulation wall thickness and an 85 C classificati
3、on. 2. APPLICATION This specification was released originally for material used in automotive electrical harnesses. Note: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Materials Approved Source List. 3. REQUIREMENTS 3.0 STANDARD REQU
4、IREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.3 CONDUCTOR (ASTM B 1/ASTM B 174) 3.3.1 The individual strands of the conductor shall be soft or annealed copper (Hard copper wire m
5、ay be used for wire sizes smaller than SAE wire size 0.5 mm2(No. 20). Annealed copper strand elongation shall conform to ASTM B 174. Hard copper strand elongations shall conform to ASTM B 1. Strand dimensions shall be controlled to yield the cross-sectional area listed for the conductor of the finis
6、hed cable per Table 1. Conductor area shall be determined by measuring individual strand diameters and calculating the sum of the individual strand areas. As an alternate method, conductor area may also be determined in accordance with ASTM B 263. 3.3.2 The strands shall be bunched per ASTM B 174. T
7、he maximum lay length shall be as specified in ASTM B 174, Table 3. Conductor strand count shall comply with Table 1 of this specification. Missing strands are not allowed. 3.3.3 Conductor resistance shall be measured by stripping 30 mm of insulation from each end of a 1050 mm cable (use of a longer
8、 specimen is optional). Solder (optional) 25 mm along each end of the specimen. Condition the specimen for a minimum of 4 hours at 23 C +/- 5 C. Measure the unsoldered length, the ambient temperature, and the resistance of the specimen. Calculate the resistance per meter. Calculate the resistance at
9、 20 C using the temperature correction method outlined in ASTM B 193. The maximum resistance values shall conform to those shown in Table 1. ENGINEERING MATERIAL SPECIFICATIONWSB-M1L134-A1Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 6 3.4 INSULATION (SAE J
10、1128) 3.4.1 The color of the vinyl insulation shall be specified on the engineering drawing of the component utilizing this material. Base and stripe color codes shall correspond to SAE J1128. Where striping is specified, the stripe shall be a minimum of 0.3 mm wide, but not more than 15% of the cir
11、cumference of the wire. The stripe shall be of the same material as the vinyl insulation. If the insulation is dyed or painted, all the cable quality tests in section 3.5 except 3.5.1, 3.5.2, 3.5.6 and 3.5.10 must be performed on the finished product. The insulation and the color may show no evidenc
12、e of peeling or cracking and must conform to the color tolerances specified. 3.4.2 The insulating material shall be a polyvinyl chloride (PVC) material, homogeneous in character, and similar to SAE J1128, Type GPT. The material shall adhere closely to, but strip readily from the conductors, leaving
13、them free of insulation and in suitable condition for applying terminals. 3.4.3 Insulation thickness shall comply with the requirements of Table 2. Measure the minimum wall thickness of a 2000 mm specimen with an optical measurement device accurate to +/- 0.01 mm (other devices may be used but the r
14、eferee method will be the optical device). Move the sample approximately 400 mm and repeat the procedure for a total of five readings. The minimum insulation thickness shall comply with the values listed in Table 2. 3.5 CABLE QUALITY (TESTS) (SAE J1128) The Physical Properties, Dielectric, and Cold
15、Bend Tests shall all be conducted in accordance with SAE J1128. Note: The following paragraphs shall be tested in accordance with SAE J1128, but with exceptions to the requirements as indicated. 3.5.1 Cable Diameter Measure the outside diameter of a 2000 mm specimen with an optical measurement devic
16、e accurate to +/- 0.01 mm (other devices may be used but the referee method will be the optical device) by taking a minimum of 2 readings approximately 90 degrees apart. Move the sample approximately 400 mm and repeat the procedure for a total of five cross-sections. The mean of all the readings wil
17、l determine the outside diameter of the cable. The outside diameter will conform to the values listed in Table 2. 3.5.2 Pinch Test (SAE J1128) Values as specified in Table 3 of this document. ENGINEERING MATERIAL SPECIFICATIONWSB-M1L134-A1Printed copies are uncontrolled Copyright 2003, Ford Global T
18、echnologies, Inc. Page 3 of 6 3.5.3 Flame Test A 600 mm. specimen shall be suspended at 45 degrees to the horizontal within a partial enclosure which allows a flow of air sufficient for complete combustion but is free from drafts. The tip of a 100 mm long flame from a 9-10 mm combustion tube shall t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSBM1L134A12003CABLEPRIMARYLOWTENSION85VINYLINSULATEDTHINWALLTOBEUSEDWITHFORDWSSM99P1111A 薄护皮型 乙烯基

链接地址:http://www.mydoc123.com/p-748937.html