1、FORD LABORATORY TEST METHOD EU-BJ 010-01 2001 0724 FORD MODIFIED OXIDATION TEST Revised Editorial - no technical change A. Cockman Application This method is used to determine the stability of lubricating oils. Evaluation of the lubricant consists in determining the tendency of oil to thicken and/or
2、 to form insolubles, varnish and strong acids. Description of Test A covered beaker containing the sample is maintained at test temperature in a temperature controlled heating device. The sample is agitated by means of a steel paddle. Aluminum, steel and copper strips are immersed in the lubricant t
3、hroughout the test. Periodic oil sampling and aluminum strip inspection permit continuous test monitoring. Apparatus Required Heating Device For temperatures of 80 - 175 OC in the range of +/- 1. Glass Beaker Tall form, 400 mL, without spout. Stirring Rod Stainless steel (Sketch No. 3 shows suitable
4、 design). Cover Suitable metal (Sketch No. 1 shows suitable design). Strip Holder For dimension (see Sketch No. 2). Test Strips Steel body skin panels, aluminum, copper (see Figure 3). Filter Apparatus Millipore XXIO 047 O0 I Date I Action I Revisions I Copyright 02001, Fad Global Technologies, Inc
5、FORD LABORATORY TEST METHOD EU-BJ 010-01 Filter Millipore type HA, Catalogue No. WP 047 O0 (0.45 microns). Balance Accuracy +/- 0.1 mg. Viscometer Suitable for this test. Timing Device For viscosity determination. Sanding Paper 220 grit. Standard CRC Varnish Manual No. 8 Source : Coordinating Resear
6、ch Council, Inc. Thirty Rockefeller Plaza New York 20. New York USA Potentiograph (suitable) Stirring Device 1 O00 +/- 50 rpm Thermometer Set of thermometers for the temperature ranges as required in the relevant Material Specification. So Ive n t (a) Normal Pentane, commercial grade (b) Petroleum N
7、aphtha U-MC004-8004-01 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 “C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specifie
8、d. Page 2 of 7 Copynght 02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD EU-BJ 010-01 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 o. 11. Procedure Set the temperature at the specified test temperature. Polish the aluminum (5), steel (I), and copper (1) strips using 220 grit paper for each lubricant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUBJ01012001FORDMODIFIEDOXIDATIONTESTPDF

链接地址:http://www.mydoc123.com/p-747812.html