FORD FLTM BU 112-02-2000 PEEL ADHESION OF PRESSURE SENSITIVE TAPES (Replaces FLTM BN 113-08)《压敏胶带的剥离粘附力 替代FLTM BN 113-08》.pdf
《FORD FLTM BU 112-02-2000 PEEL ADHESION OF PRESSURE SENSITIVE TAPES (Replaces FLTM BN 113-08)《压敏胶带的剥离粘附力 替代FLTM BN 113-08》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BU 112-02-2000 PEEL ADHESION OF PRESSURE SENSITIVE TAPES (Replaces FLTM BN 113-08)《压敏胶带的剥离粘附力 替代FLTM BN 113-08》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BU 112-02 Date Action Revisions 2000 11 13 Revised Editorial no technical change A. Cockman 2000 03 02 Editorial no technical change A. Cockman 1995 05 15 Printed copies are uncontrolled Pag e 1 of 8 Copyright 2000, Ford Global Technologies, Inc. PEEL ADHESION OF PRESSUR
2、E SENSITIVE TAPES Application This method determines the peel adhesion loads of various pressure sensitive two sided adhesive tapes when bonded to various substrates. Materials and Apparatus Required Panel - Foil Anodized alumi num, dimensions defined by each Method. Roller Rubber covered steel as d
3、escribed in ASTM D 1000. (Roller must be capable of having weights added to it). Test Specimen Dimensions defined by each Method. Tensile Test Machine Scale range 0 - 50 kg Vinyl Test Bar Source: Standard Products Co. Material: PVC Test Bars 2401 South Gulley Road EX3786 HMS - 4632 - F901 Dearborn M
4、I 48126 44 - 47 Shore D +/ - 10 % Isopropyl Alcohol and Water Mixture 50/50 blend of technical grade isopropyl alcohol and dei onized water. Bar Clip - steel, see Figure 5 Tissue Lint free Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a contro
5、lled atmosphere of 23 +/ - 2 C and 50 +/ - 5 % relative humidity for not less t han 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BU 112-02 Page 2 of 8 Copyright 2000, Ford Global Technologies, Inc. Procedure Note: Identify which s
6、ide of the tape will be bonded to the part/panel. (Many pressure sensitive tapes have different adhesives on the liner side and n on -liner sides. This allows for adhesion of dissimilar substrates. The liner side is the side which bonds to the paint or second surface. The non - liner side is the sid
7、e which is bonded to the part or first surface.) Method A - 90 degree Peel Adhesion o n Component or painted test panel 1. Clean the original part/painted panel with one wash using the isopropyl/ water solution and wipe dry with a tissue. 2. Cover 12 - 19 mm of one of the ends of the original part/p
8、ainted panel with masking tape. 3. Cut a specimen of the tape to be tested at least 150 mm long and 13 mm wide. 4. When testing adhesion to the part (first surface), apply the tape to be tested to the part/panel in such a way that the formation of air bubbles between tape and substrate is avoi ded w
9、ithout exerting appreciable pressure on the tape. Remove the liner from the tape and position a strip of anodized aluminum (dull side to pressure sensitive adhesive) 19 x 200 x 0.125 mm on the tape. 5. When testing adhesion to the paint (second surf ace), apply a strip of anodized aluminum (dull sid
10、e to pressure sensitive adhesive) 19 x 200 x 0.125 mm to the non -liner side of the tape. Remove the release liner from the liner side and apply the aluminum/tape sample to the part/panel in such a way that the formation of air bubbles between tape and substrate is avoided without exerting appreciab
11、le pressure on the tape. 6. Apply pressure to the aluminum by rolling with a 2 kg roller once in each direction at the rate of 50 mm/second. 7. Allow the specim en to age as specified in the applicable engineering document. 8. Test the panels after conditioning as follows (see Figure 1): Clamp the f
12、ixture for holding the part or panel in the stationary jaw of the tensile tester. The fixture shall be capable of maintaining a 90 degree angle of peel throughout the test. Place a test part/panel into the holding fixture and insert an extended end of the aluminum tape into the crosshead jaw. Initia
13、te jaw separation at a rate of 300 mm per minute. Continue the test until all of the tape has been removed from the part. 9. Record the average peel force in newtons, ignoring the first and last 25 mm of peel. 10. Repeat steps 1 through 9 for four additional samples and average the results. Method B
14、 - 180 or T - peel A dhesion on Component 1. Cut a specimen of the tape to be tested at least 150 mm long and 13 mm wide. FORD LABORATORY TEST METHOD BU 112-02 Page 3 of 8 Copyright 2000, Ford Global Technologies, Inc. 2. Apply the tape sample to the dull side of an aluminum strip 16 x 300 x 0.125 m
15、m. Leave a 25 mm tab at each end of the aluminum strip. No cleaning of the strip is necessary. 3. Remove the liner from the tape sample. Apply another aluminum strip, dull side to the foam, to the sample. The final construction consists of the foam tape sample between two aluminum strips. 4. Roll th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBU112022000PEELADHESIONOFPRESSURESENSITIVETAPESREPLACESFLTMBN11308 胶带 剥离 粘附 替代 FLTMBN11308PDF

链接地址:http://www.mydoc123.com/p-747538.html