FORD ESF-M1L119-A-2003 CABLE LOW TENSION - VINYL INSULATED (105 - TINNED MULTIPLE CONDUCTOR TO BE USED WITH FORD WSS-M99P1111-A 《乙烯树脂绝缘的(105℃)锡包多导线低压电缆 与标准FORD WSS-M99P1111-A一起使.pdf
《FORD ESF-M1L119-A-2003 CABLE LOW TENSION - VINYL INSULATED (105 - TINNED MULTIPLE CONDUCTOR TO BE USED WITH FORD WSS-M99P1111-A 《乙烯树脂绝缘的(105℃)锡包多导线低压电缆 与标准FORD WSS-M99P1111-A一起使.pdf》由会员分享,可在线阅读,更多相关《FORD ESF-M1L119-A-2003 CABLE LOW TENSION - VINYL INSULATED (105 - TINNED MULTIPLE CONDUCTOR TO BE USED WITH FORD WSS-M99P1111-A 《乙烯树脂绝缘的(105℃)锡包多导线低压电缆 与标准FORD WSS-M99P1111-A一起使.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 06 25 Revised Para 3.0 inserted; Para 3.7, 3.8, 3.9, 3.10, 3.11, 4 deleted 1990 07 11 DE00-E00107002060 Revised & Reactivated J. Huebner 1982 11 29 CF4M-RD887294-21 Released Printed copies are uncontrolled Copyright 2003, Ford Global Tech
2、nologies, Inc. Page 1 of 6 CABLE, LOW TENSION VINYL INSULATED (105 C) TINNED ESF-M1L119-A MULTIPLE CONDUCTOR 1. SCOPE The material defined by this specification is a stranded vinyl covered, multiple conductor, low tension cable. The vinyl covering shall be 105 C classification. 2. APPLICATION This s
3、pecification was released originally for material used for automotive electrical harnesses. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 WIRE
4、SIZE Shall be specified on the engineering drawing and/or release according to the SAE wire size numbers appearing in Table I. The number of conductors is also to be specified on the engineering drawing. Example: # 16 gage ESF-M1L119-A, 5 conductors. 3.2 COLOR The color of the vinyl cover shall be s
5、pecified on the engineering drawing and/or release by a numerical suffix following the letter suffix of the material desired. The numerical color coding suffixes shall correspond to the following: 0 - Black 5 - Green 1 - Brown 6 - Blue 2 - Red 7 - Violet 3 - Orange 8 - Gray 4 Yellow 9 - White or nat
6、ural Example: #16 gage ESF-M1L119-A1 shall designate a stranded 16 gage, brown vinyl covered, soft or annealed tinned copper conductor, corresponding to the requirements of this specification. The first color coding numerical suffix shall be the base or body color of the finished cable and the secon
7、d number shall designate the tracer or other auxiliary marking. ENGINEERING MATERIAL SPECIFICATIONESF-M1L119-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 6 3.3 CABLE QUALITY Shall meet all of the requirements listed herein and must be equal to the origina
8、l approved purchase sample. 3.4 WIRE QUALITY The strands of the conductors prior to stranding shall consist of ESF-M2L3-A, soft or annealed tinned copper wire. 3.5 CABLE CONSTRUCTION See Tables I and II The cross sectional area of stranded conductors shall not be less than 98% of the values specifie
9、d in Table I. 3.6 INSULATION QUALITY Shall be a good grade vinyl chloride copolymer which will pass the following test requirements: The material shall adhere closely to, but strip readily from the conductors, leaving them reasonably clean and in suitable condition for soldering. Insulation thicknes
10、s shall be in accordance with Table II for the various wire sizes and shall be determined by measuring the diameter over the insulation, then removing the insulation and measuring the diameter of the conductor. Half of the difference of the two measurements shall be considered as the wall thickness.
11、 3.6.1 Mechanical Properties Tear Strength, min 8.9 N Test Method: Split insulation between conductors. Pull at 500 +/- 25 mm/minute. 3.6.2 High Temperature Resistance A strip of the insulation 25 mm long shall be removed from each end of a 610 mm sample of the finished cable. The sample shall be su
12、spended around a cylindrical mandrel having a diameter specified in Table III. Each end of the conductor shall have suspended from it, the weight shown in Table III. This condition shall be maintained for 120 h in a mechanical convection oven maintained at a temperature of 135-137 C. When cool, the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESFM1L119A2003CABLELOWTENSIONVINYLINSULATED105TINNEDMULTIPLECONDUCTORTOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-746113.html