EN 60721-3-1-1997 en fr Classification of Environmental Conditions Part 3 Classification of Groups of Environmental Parameters and Their Severities Section 1 Storage (Remains Curre.pdf
《EN 60721-3-1-1997 en fr Classification of Environmental Conditions Part 3 Classification of Groups of Environmental Parameters and Their Severities Section 1 Storage (Remains Curre.pdf》由会员分享,可在线阅读,更多相关《EN 60721-3-1-1997 en fr Classification of Environmental Conditions Part 3 Classification of Groups of Environmental Parameters and Their Severities Section 1 Storage (Remains Curre.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、STD*BSI BS EN b0721-3-L-ENGL II977 = lb24bb9 Ob317b2 720 BRITISH STANDARD Classification of environmental conditions Part 3. Classification of groups of environmental parameters and their severities Section 1. Storage The European Stan- EN 6072151 : 1997 has the status of a , British Standard ICs 19
2、.040 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGEPT LAW BS EN 60721-3-1 : 1997 IEC 607213-1 : 1997 STD-BSI BS EN bD721-3-1-ENGL 1997 lb29bb9 Ob317b3 bb7 9 BS EN 607213-1 : 1997 This Briish Standard, having been prepared under the direction of the Elcal Sector Board, was publishe
3、d under the authority of the standards Board and comes into effect on 16 August 1997 National foreword “his British Standard is the higlish language version of EN 60721-3-1 : 1997. It is identical with IEC 60721-3-1 : 1997. It supemedes BS EN 60721-3-1 : 1993 which is withdrawn. The UK participation
4、 in its prepamtion was entrusted to Technid Committee GEIJSO, EnvirOnmental testing of electmtechnical products, which has the responsibilityto: - aid enquirem to understand the tee - present to the responsible intmnationaVEumpean committee any enquiries on the interpretation, or proposals for chang
5、e, and keep the UK interests iIlf0 - monitor reW intedonal and European developments and promulgate them in the UK. A iist of organizations represented on this committee can be obtained on request to its secretary. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards nom in
6、clude an annex which lists normative references to internationai publications with their corresponding European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitled internationai Stan-
7、Correspondence index, or using the Find facity of the BSI Standards Electronic Catalogue. Compliance with a British Standard does not of itself confer immunity from legai obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 23, a b
8、lank page, an inside back cover and a back cover. Amendments issued since publication 0 BSI 1997 ISBN O 880 27809 3 EUROPEAN STANDARD NORME EUROPEENNE EUROPISCHE NORM EN 60721-3-1 March 1997 English version Classification of environmental conditions Patt 3: Classification of groups of environmental
9、parameters and their severities Section 1: Storage -.(IEC 60721-3-1:1997) Classification des conditions denvironnement Teil 3: Klassen von Partie 3: Classification des groupements des agents denvironnement et de leurs sdvdrit6s Section 1: Stockage (CE1 6072 1 -3- 1 : 1 997) Klassifizierung von Umwel
10、tbedingungen Umwelteinflugren und deren Grenzwerte Hsuptabschnitt 1 : Langzeitiagerung - - (IEC 60721-3-1 : 1997) _. - _I II This European Standard was appiovd bv CENELEC on 1998-1 2-09. CENELEC mom heating, cooling or humidification being used where necessary to maintain required conditions; exposu
11、re to some solar and heat radiation; movement of surrounding air, such as through open windows; without particular risk of biological attacks; with normal levels of contaminants experienced in urban areas with industrial activities scattered over the whole area, or with heavy traffic; without specia
12、l precautions to minimize presence of dust or sand, but not situated in proximity to dust and sand sources; experiencing vibration of low significance. In addition to the conditions covered by IEll, IE12 applies to locations having neither temperature nor humidity control; heating may be used to rai
13、se low temperatures; with buildings constructed to avoid extremely high temperatures; with risk of condensation, dripping water, formation of ice. In addition to the conditions covered by IE12, IE13 applies to locations in buildings provided with minimal protection from daily variations of outside c
14、limate; exposure to solar radiation, wind-driven precipitation; with risk of mould growth and attacks by animals except termites; in close proximity to sand and dust sources, including those of urban areas. In addition to the conditions covered by IE13, IE14 applies to non-weatherprotected locations
15、; negligible heat radiation; fair movement of surrounding air; experiencing significant shock, for example that transmitted from machines or passing vehicles in the vicinity. STDOBSI BS EN bO721-3-1-ENGL 1777 = Lb24bb7 Ob31783 455 Page 20 EN 60721-3-1 : 1997 Annex C (informative) Explanation of the
16、environmental conditions in tropical areas as specified in classes 1 K10 and 1 K11 C.l General The tropics are the areas within the Northern and Southern tropics (between 2327 south and 2327 north). In tropical areas, the following types of open-air climate, as specified in IEC 721-2-1, apply: Warm
17、Dry (WDr) Mild Warm Dry (MWDr) Extremely Warm Dry (EWDr) Warm Damp (WDa) Warm Damp Equable (WDaE) The tropics are the zones of the earth in which, during daytime, high temperatures, frequently combined with high precipitation, prevail. In these areas, seasonal changes are scarcely pronounced. The tr
18、opical climate extends from warm damp climatic conditions in tropical rainforests at the equator to the warm dry climate in the deserts near the tropics. Consequently, two types of tropical climate should be distinguished: - tropical dry as a combination of the Warm Dry, Mild Warm Dry and Extremely
19、Warm Dry types of climate; and - tropical damp as a combination of the Warm Damp and Warm Damp Equable types of climate. There are also regions where the climate, owing to the particular altitude, deviates considerably from the usual conditions of those latitudes, for example solar radiation and air
20、 pressure or ice and snow on mountain summits. In many areas in the tropics, environmental conditions are identified by uniform conditions, and in other regions by very extreme climatic conditions: Balanced conditions: - minimum daily temperature fluctuations of less than 1 OC and annual temperature
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN60721311997ENFRCLASSIFICATIONOFENVIRONMENTALCONDITIONSPART3CLASSIFICATIONOFGROUPSOFENVIRONMENTALPARAMETERSANDTHEIRSEVERITIESSECTION1STORAGEREMAINSCURREPDF

链接地址:http://www.mydoc123.com/p-718701.html