EN 12543-3-1999 en Non-Destructive Testing - Characteristics of Focal Spots in Industrial X-Ray Systems for Use in Non-Destructive Testing - Part 3 Slit Camera Radiographic Method《.pdf
《EN 12543-3-1999 en Non-Destructive Testing - Characteristics of Focal Spots in Industrial X-Ray Systems for Use in Non-Destructive Testing - Part 3 Slit Camera Radiographic Method《.pdf》由会员分享,可在线阅读,更多相关《EN 12543-3-1999 en Non-Destructive Testing - Characteristics of Focal Spots in Industrial X-Ray Systems for Use in Non-Destructive Testing - Part 3 Slit Camera Radiographic Method《.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、STDaBSI BS EN 12543-3-ENGL 1997 W Lb2LibbS 0839975 480 M BRITISH STANDARD Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 3: Slit camera radiographic method The European Standard EN 1254331999 has the status of a British
2、Standard ICs 19. loo BS EN 12 543-3: 1999 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW STD=BSI BS EN 12543-3-ENGL 1997 I 1b24bbS 081977b 317 BS EN 12543-3:1999 diredion of the Engineering Amd.No. Date Sector Committee, was published under the authority of the Standards Comm
3、ittee and comes into effect on 15 December 1999 National foreword Comments This British Standard is the English language version of EN 1254331999. The UK participation in its preparation was entrusted to Technical Committee WEW46, Nondestructive testing, which has the responsibility to: - aid enquir
4、em to understand the text; - present to the responsible European committee any enquiries on the - monitor related intemational and European developments and promulgate interpretation, or prop the other parts are the following: EN 12543-1 , Non-destructive testing - Characteristics of focal spots in
5、industrial X-ray systems for use in non- destructive testing - Part 1: Scanning method. EN 12543-2, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 2: Pinhole camera radiographic method EN 12543-4, Non-destructive testin
6、g - Charactenstics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 4: Edge method. EN 12543-5, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 5: Measurement of the effective focal s
7、pot size of mini and micro focus X-ray tubes. QBSI 12-1999 Page 4 EN 12543-311 999 In trod u ct i o n In order to cover the different requirements for focal spot size measurement, five different methods are described in EN 12543-1 to EN 12543-5. The scanning method (EN 12543-1) is dedicated to those
8、 applications where quantitative values for the intensity distribution and spot size are needed, i. e. calibration and image processing purposes. The radiographic methods (EN 12543-2 and EN 12543-3) describe the traditional techniques and are dedicated for certification purposes and for field applic
9、ations up to 200 kV. Where no pinhole or slit cameras are available in the field, the edge method (EN 12543-4) may be applied. It represents a very simple method for field application. In order to cover also the micro focus systems, a specific method is presented in EN 12543-5. 1 Scope This European
10、 Standard specifies a method for the measurement of focal spot dimensions above 0,l mm of X- ray systems up to and including 500 kV tube voltage by means of the slit camera radiographic method. The voltage applied for this measurement is restricted to 200 kV. The image quality and the resolution of
11、X-ray images depend highly on the characteristics of the focal spot, in particular the size and the twodimensional intensity distribution in the object plane. For the characterization of commercial X-ray tube types (.e. for advertising or trade) the specific maximum values of annex A should be prefe
12、rred. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or
13、revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 584-1, Non-destructive testing - Industrial radiographic film - Part 7; Classification of
14、 film systems for industrial radiography. EN 12543-1, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destnrctive - testing - Part ?: Scanning method. 3 Terms and definitions For the purposes of this standard, the following definition applies: Foc
15、al spot: the X-ray emitting area on the anode of the X-ray tube as seen from the measuring device EN 12543-11. 4 Test equipment 4.1 The Slit Camera The slit camera shall consist of a block with a slit with the dimensions given in figure I. It shall be made from tungsten or a similiar absorbant mater
16、ial. 8BSI 12-1999 STD.BS1 BS EN 12543-3-ENGL 1777 81 Lb24bb7 08L7981 784 Page 5 EN 12543-3: 1999 Dimensions in millimetre Key 1 symmetry axis Figure 1 - Essential dimensions of the black and slit 4.2 The angle between the beam direction and the axis of the slit symmetry (see figure 2) shall be small
17、er than 3. When deviating from figure 2, the direction of the beam shall be indicated. Alignment and position of the slit camera O BSI 12-1999 Page 6 EN 12543-3: 1999 1 focal spot 2 beam direction 3 maximum deviation of the slit symmetry axis Figure 2 -Alignment of the slit camera The incident face
18、of the slit shall be placed at a distance m from the focal spot so that the variation of the magnification over the length of the actual focal spot does not exceed i 5 % in the beam direction, see figure 3, according to following formulae: n/m=E n/(m+k)20,95 n/(m-p)S 1,05E where E is the magnificati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1254331999ENNONDESTRUCTIVETESTINGCHARACTERISTICSOFFOCALSPOTSININDUSTRIALXRAYSYSTEMSFORUSEINNONDESTRUCTIVETESTINGPART3SLITCAMERARADIOGRAPHICMETHODPDF

链接地址:http://www.mydoc123.com/p-706444.html