1、 EIA STANDARD TP-22B Simulated Life Test Procedure for Electrical Connectors EIA/ECA-364-22B (Revision of EIA-364-22A) March 2000 ANSI/EIA-364-22B-2000 (R2012) Approved: March 10, 2000 Reaffirmed: December 18, 2012 EIA/ECA-364-22B NOTICE EIA Engineering Standards and Publications are designed to ser
2、ve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Stan
3、dards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members,
4、 whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any
5、 obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and th
6、e IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability o
7、f regulatory limitations before its use. (From Standards Proposal No. 4415 formulated under the cognizance of the CE-2.0 National Connector Standards Committee and reaffirmed per Standards Proposal No. 5252.04). Published by Electronic Components Industry Association 2012 Engineering Department 2214
8、 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, co
9、ntact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources . 1 2.1 Equipment . 1 3 Test specimen 1 3.1 Description 1 3.2 Preparation 1 4 Test procedure . 3 4.
10、1 Test condition A, general duty land 3 4.2 Test condition B, heavy duty 4 4.3 Test condition C, aircraft 4 4.4 Test condition D, marine 5 4.5 Test condition E, underwater 5 5 Details to be specified . 6 6 Test documentation . 7 Table 1 Temperature limits for use in test cycles 3 2 Pressure level 6
11、Figure 1 Wiring diagram typical . 2 (This page left blank) EIA/ECA-364-22B Page 1 TEST PROCEDURE No. 22B SIMULATED LIFE TEST PROCEDURE FOR ELECTRICAL CONNECTORS (From EIA Standards Proposal No. 4415, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previously
12、 published in EIA-364-22A.) 1 Introduction 1.1 Scope This standard establishes test methods to determine the adequacy of a connector or socket to perform its operational function on land (general and heavy duty), aircraft, marine or underwater for the representative time period of application. This
13、method shall not be used prior to low level measurement per EIA-364-23. 2 Test resources 2.1 Test equipment 2.1.1 Separate chambers may be used to conduct the tests noted for extreme temperature conditions. Chambers shall recover within 2 minutes after specimen transfer. Room temperature shall be 21
14、 C 3 C (70 F 5 F). 2.1.2 Pressure vessels used to conduct the hydrostatic pressure tests shall be designed in accordance with the ASME Pressure Vessel Code. 2.1.3 Vibration test equipment shall be specified. 3 Test specimen 3.1 Description A test specimen shall consist of a mateable assembly. 3.2 Pr
15、eparation 3.2.1 The test specimens shall be visually examined for chips, cracks, tears, loose or missing parts, proper lubrication, proper assembly and mateability. Any specimen that shows degradation, wear or any other physical defect shall be replaced before testing. EIA/ECA-364-22B Page 2 3.2.2 T
16、he test specimens shall be wired and assembled according to the manufacturers or military recommendations. Maintenance aging preconditioning shall be conducted in accordance with prescribed procedures on all connectors having removable contacts and shall consist of one removal and insertion of all o
17、f the contacts in each plug and receptacle. 3.2.3 Unless otherwise specified, the test specimens shall be wired with conductor sizes matching the contact size in the connector. The wire type and configuration shall be that specified, or that recommended by the connector manufacturer when no military
18、 specification exists. 3.2.4 Alternate contacts of the connector shall be wired in a series circuit, see figure 1, between a source and a load such that adjacent contacts are at opposite potential wherever possible. In the event that the connectors have more than one size contact, each contact size
19、shall be wired as separate connectors. Figure 1 - Wiring diagram typical 3.2.5 The mated, wired connectors shall be connected between a source and a load such that each circuit will be continuously carrying the maximum operating voltage. The operating voltage and rated current shall be that specifie
20、d or that recommended by the manufacturer when no military specification exists. 3.2.6 The test cycles described herein represent a particular area of connector application and are complete within themselves. Testing of one connector specimen shall be limited to one application category although thi
21、s cycle may be run as many times as required to provide the necessary number unit hours. 3.2.7 The criteria for failure of the test specimen shall be determined by the following: The test specimens shall operate the load specified in 3.2.5 throughout the entire cycle. The total life of the connector
22、 shall then be the total number of unit hours the load is operated. EIA/ECA-364-22B Page 3 4 Test procedure 4.1 Test condition A, general duty land The test specimens initially at room temperature shall be divided into two equal groups, placed in suitable chambers, and subjected to the following cyc
23、les: 4.1.1 Group I 4.1.1.1 Initial chamber conditions to be 21 C 3 C (70 F 5 F), 50% 5% relative humidity; maintain for 11 hours. 4.1.1.2 Raise chamber condition to 39 C 3 C (100 F 5 F), 80% 5% relative humidity to be accomplished over 1 hour period; maintain conditions for 11 hours. 4.1.1.3 Return
24、to initial specimen condition (room temperature), with drop accomplished over a 1 hour period. 4.1.2 Group II, see table 1 4.1.2.1 Initial chamber conditions to the specified limit of T1 3 C ( 5 F) with uncontrolled humidity; maintain for 10 hours. 4.1.2.2 Drop chamber conditions to the same applica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EIAECA36422B2000TP22BSIMULATEDLIFETESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-705008.html