1、 EIA STANDARD TP-22B Simulated Life Test Procedure for Electrical Connectors EIA/ECA-364-22B (Revision of EIA-364-22A) March 2000 ANSI/EIA-364-22B-2000 (R2012) Approved: March 10, 2000 Reaffirmed: December 18, 2012 EIA/ECA-364-22B NOTICE EIA Engineering Standards and Publications are designed to ser
2、ve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Stan
3、dards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members,
4、 whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any
5、 obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and th
6、e IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability o
7、f regulatory limitations before its use. (From Standards Proposal No. 4415 formulated under the cognizance of the CE-2.0 National Connector Standards Committee and reaffirmed per Standards Proposal No. 5252.04). Published by Electronic Components Industry Association 2012 Engineering Department 2214
8、 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, co
9、ntact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources . 1 2.1 Equipment . 1 3 Test specimen 1 3.1 Description 1 3.2 Preparation 1 4 Test procedure . 3 4.
10、1 Test condition A, general duty land 3 4.2 Test condition B, heavy duty 4 4.3 Test condition C, aircraft 4 4.4 Test condition D, marine 5 4.5 Test condition E, underwater 5 5 Details to be specified . 6 6 Test documentation . 7 Table 1 Temperature limits for use in test cycles 3 2 Pressure level 6
11、Figure 1 Wiring diagram typical . 2 (This page left blank) EIA/ECA-364-22B Page 1 TEST PROCEDURE No. 22B SIMULATED LIFE TEST PROCEDURE FOR ELECTRICAL CONNECTORS (From EIA Standards Proposal No. 4415, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previously
12、 published in EIA-364-22A.) 1 Introduction 1.1 Scope This standard establishes test methods to determine the adequacy of a connector or socket to perform its operational function on land (general and heavy duty), aircraft, marine or underwater for the representative time period of application. This
13、method shall not be used prior to low level measurement per EIA-364-23. 2 Test resources 2.1 Test equipment 2.1.1 Separate chambers may be used to conduct the tests noted for extreme temperature conditions. Chambers shall recover within 2 minutes after specimen transfer. Room temperature shall be 21
14、 C 3 C (70 F 5 F). 2.1.2 Pressure vessels used to conduct the hydrostatic pressure tests shall be designed in accordance with the ASME Pressure Vessel Code. 2.1.3 Vibration test equipment shall be specified. 3 Test specimen 3.1 Description A test specimen shall consist of a mateable assembly. 3.2 Pr
15、eparation 3.2.1 The test specimens shall be visually examined for chips, cracks, tears, loose or missing parts, proper lubrication, proper assembly and mateability. Any specimen that shows degradation, wear or any other physical defect shall be replaced before testing. EIA/ECA-364-22B Page 2 3.2.2 T
16、he test specimens shall be wired and assembled according to the manufacturers or military recommendations. Maintenance aging preconditioning shall be conducted in accordance with prescribed procedures on all connectors having removable contacts and shall consist of one removal and insertion of all o
17、f the contacts in each plug and receptacle. 3.2.3 Unless otherwise specified, the test specimens shall be wired with conductor sizes matching the contact size in the connector. The wire type and configuration shall be that specified, or that recommended by the connector manufacturer when no military
18、 specification exists. 3.2.4 Alternate contacts of the connector shall be wired in a series circuit, see figure 1, between a source and a load such that adjacent contacts are at opposite potential wherever possible. In the event that the connectors have more than one size contact, each contact size
19、shall be wired as separate connectors. Figure 1 - Wiring diagram typical 3.2.5 The mated, wired connectors shall be connected between a source and a load such that each circuit will be continuously carrying the maximum operating voltage. The operating voltage and rated current shall be that specifie
20、d or that recommended by the manufacturer when no military specification exists. 3.2.6 The test cycles described herein represent a particular area of connector application and are complete within themselves. Testing of one connector specimen shall be limited to one application category although thi
21、s cycle may be run as many times as required to provide the necessary number unit hours. 3.2.7 The criteria for failure of the test specimen shall be determined by the following: The test specimens shall operate the load specified in 3.2.5 throughout the entire cycle. The total life of the connector
22、 shall then be the total number of unit hours the load is operated. EIA/ECA-364-22B Page 3 4 Test procedure 4.1 Test condition A, general duty land The test specimens initially at room temperature shall be divided into two equal groups, placed in suitable chambers, and subjected to the following cyc
23、les: 4.1.1 Group I 4.1.1.1 Initial chamber conditions to be 21 C 3 C (70 F 5 F), 50% 5% relative humidity; maintain for 11 hours. 4.1.1.2 Raise chamber condition to 39 C 3 C (100 F 5 F), 80% 5% relative humidity to be accomplished over 1 hour period; maintain conditions for 11 hours. 4.1.1.3 Return
24、to initial specimen condition (room temperature), with drop accomplished over a 1 hour period. 4.1.2 Group II, see table 1 4.1.2.1 Initial chamber conditions to the specified limit of T1 3 C ( 5 F) with uncontrolled humidity; maintain for 10 hours. 4.1.2.2 Drop chamber conditions to the same applica
25、ble limit of T2 3 C ( 5 F), with uncontrolled humidity; drop to be accomplished over a 2-hour period; maintain condition for 10 hours. 4.1.2.3 Return to initial specimen condition (room temperature with rise accomplished over a 2 hour period. 4.1.3 After each group completed one cycle as described a
26、bove, the specimens are unmated, remated, and switched so that group II goes through the group I cycle and group I goes through group II cycle. This provides a 48-hour cycle for each group. The transfer of specimens shall be accomplished within the first hour of the first phase of each cycle. Provis
27、ions shall be made to remove power from the connectors while they are unmated and remated. Table 1 - Temperature limits for use in test cycles Limit Temperature (T1) Temperature (T2) I 74 C (165 F) -55 C (-67 F) II 105 C (221 F) -55 C (-67 F) III 150 C (302 F) -55 C (-67 F) IV 200 C (392 F) -55 C (-
28、67 F) EIA/ECA-364-22B Page 4 4.2 Test condition B, heavy duty The test specimens initially at room temperature shall be divided into three groups, placed in suitable chambers and fixtures and subjected to the following cycles: 4.2.1 Group I 4.2.1.1 Initial chamber conditions 21 C 3 C (70 F 5 F), 50%
29、 5% relative humidity; maintain for 11 hours. 4.2.1.2 Within 1 hour change chamber conditions to 38 C 3 C (100 F 5 F), 80% 5% relative humidity; maintain for 11 hours. 4.2.1.3 Within 1 hour, return to initial conditions. 4.2.2 Group II 4.2.2.1 Initial chamber conditions 74 C 3 C (165 F 5 F), humidit
30、y uncontrolled. 4.2.2.2 With 2 hours, change to -55 C 3 C (-67 F 5 F), humidity uncontrolled; maintain for 10 hours. 4.2.3 Group III 4.2.3.1 Mount specimens, for vibration, in plane specified. 4.2.3.2 Vibrate as specified in continuous cycles for a duration of 24 hours. 4.2.4 After each group of spe
31、cimens has completed the 24-hour phase, they shall be rotated and tested to the next higher phase (group I goes to group II, group II goes to group III, group III goes to group I). This is continued until each group of specimens has been through each group of tests for a total of a 72-hour cycle. Ea
32、ch connector shall be unmated and remated during the transfer from group to group. Provisions shall be made to remove power from the connectors while they are unmated and remated. 4.3 Test condition C, aircraft The test specimens shall be placed in a sealed chamber of such size that can readily be a
33、ttached to a vibrator table. The wiring of the connectors, see 3.2.2, between the load and the connector, and between the source and the connector shall be such as to maintain the sealed condition of the chamber. The chamber conditions shall provide the following cycle: 4.3.1 Reduce chamber pressure
34、 to 4.39 x 103Pa 0.68 x 103Pa (1.3 inches of mercury 0.2 inch of mercury). Maintain for 8 hours. EIA/ECA-364-22B Page 5 4.3.2 Inject air, at atmospheric pressure, into the top of the chamber. The injected air shall be 88 C 3 C (190 F 5 F) and shall bubble through water at 88 C 3 C (190 F 5 F). Maint
35、ain for 4 hours at atmospheric pressure. 4.3.3 During the last hour of 4.3.2 vibrate chamber and connector package through one complete cycle as specified. This provides a 12 hour cycle. 4.4 Test condition D, marine The test specimens, initially at room temperature, shall be placed in suitable chamb
36、ers and subjected to the following cycle: 4.4.1 Initial chamber contains 21 C 3 C (70 F 5 F), 50% 5% relative humidity; maintain for 10 hours. 4.4.2 Within 1 hour change chamber conditions to 49 C 3 C (120 F 5 F), 80% 5% relative humidity; maintain for the remainder of a 10 hour period. 4.4.3 Immedi
37、ately upon completion of 4.4.2 remove specimens and submerge immediately in synthetic ocean water, (see ASTM D 1141-52) at room temperature. (Specimens shall be removed as soon as entire connector has passed beneath the surface). 4.4.4 Within 1/2 hour from completion of 4.4.2, place specimens in a c
38、hamber -55 C 3 C (-67 F 5 F), maintain for 2 hours. 4.4.5 The test specimens shall carry the load specified in 3.2.5 through 4.4.1, 4.4.2 and 4.4.4 of this cycle. At the end of the cycle, connectors shall be allowed to warm to room temperature and shall be unmated and remated. This provides a 23 hou
39、r cycle. Provisions shall be made to remove power from connectors while they are unmated and remated. 4.5 Test condition E, underwater The test specimens initially at room temperature shall be divided into two groups and subjected to the following cycles: 4.5.1 Group I 4.5.1.1 Initial chamber condit
40、ions 21 C 3 C (70 F 5 F), 50% 5% relative humidity; maintain for 10 hours. 4.5.1.2 Within 1 hour change chamber conditions to 49 C 3 C (120 F 5 F), 80% 5% relative humidity; maintain for the remainder of a 10 hour period. 4.5.1.3 With 1/2 hour place specimens in a chamber at -55 C 3 C (-67F 5 F), ma
41、intain for the remainder of a 4 hour period. EIA/ECA-364-22B Page 6 4.5.2 Group II 4.5.2.1 Submerge specimens in synthetic ocean water, see ASTM D 1141-52, at room temperature to the specified pressure limit of P 5%; see table 2; maintain for 23 hours. Table 2 - Pressure level Level Pressure (P) 5%,
42、 Pa (lb/in2) I 6.89 x 106(1,000) II 2.41 x 107(3,500) III 6.89 x 107(10,000) IV 1.10 x 108(16,000) 4.5.2.2 Remove specimens from pressure vessel and allow 1 hour for air drying. 4.5.3 After each group has completed one cycle as described above, the group II specimens are unmated, remated and switche
43、d so group I specimens go through group II test and group II specimens go through group I tests to provide a 48 hour cycle. The transfer of specimens shall be accomplished within the first hour of the first phase of each group. Provisions shall be provided to remove power from connectors while they
44、are unmated and remated. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Number of specimens to be tested 5.2 Conductor size, if not matched to the contact size; see 3.2.3 5.3 Wire type and configuration; see 3.2.3 5.4 Operating voltage and rated c
45、urrent; see 3.2.5 5.5 Number of unit cycles required; see 3.1 6 5.6 Related test condition to be tested to; see 4.1, 4.2, 4.3, 4.4 and 4.5 5.7 Temperature limits, where applicable; see table 1 and 4.1.2 5.8 Pressure limits; where applicable; see table 2 and 4.5 2.1 5.9 Vibration mounting and test co
46、ndition, where applicable: see 4.2.3 and 4.3.3 EIA/ECA-364-22B Page 7 6 Documentation Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1 Title of test 6.2 Specimen description, including fixturing if applicable 6.3 Test equipment used, and date
47、 of last and next calibration 6.4 Test procedure 6.5 Values and observations 6.6 Name of operator and date of test ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate i
48、nformation below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 170 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immedia
49、te: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 170 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.eciaonline