1、 EIA STANDARD TP-110 Thermal Cycling Test Procedure for Electrical Connectors and Sockets EIA/ECA-364-110 August 2006 EIA/ECA-364-110 ANSI/EIA-364-110-2006(R2013) Approved: August 25, 2006 Reaffirmed: January 15, 2013 NOTICE EIA Engineering Standards and Publications are designed to serve the public
2、 interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Pub
3、lications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the
4、standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation w
5、hatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC documen
6、t can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory
7、limitations before its use. (Created under Standards Proposal No. 5064 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards and reaffirmed under Project No. 5253.09). Published by Electronic Components Industry Association 2013 Engineering Department
8、 2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For informatio
9、n, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) i CONTENTS Clause Page1 Introduction . 11.1 Scope . 12 Test resources . 12.1 Test equipment 13 Test specimen 13.1 Description 13.2 Preparation 14 Test procedure . 25 D
10、etails to be specified . 46 Test documentation . 4Table 1 Test condition . 32 Test duration . 3ii(This page left blank) EIA/ECA-364-110 Page 1 TEST PROCEDURE No. 110 THERMAL CYCLING TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5064, formulated under the cogni
11、zance CE-2.0 EIA Committee on National Connector Standards.) 1 Introduction 1.1 Scope This standard establishes a test method to expose connectors and sockets to extremes of high and low temperatures at a specified ramp up and ramp down rate. NOTE If the ramp time between temperature extremes is 2.0
12、 minutes, this test procedure shall not be used. The procedure as specified in EIA-364-32 (Thermal Shock (Temperature Cycling) Test Procedure for Electrical Connectors and Sockets) shall be performed as a substitute. 2 Test resources 2.1 Test equipment The chamber and accessories shall be constructe
13、d of material that will not be affected by the temperature extremes as specified. A suitable open screen tray, rack or other suitable holding feature shall be provided to ensure that the specimen shall be exposed to circulating air. Specimens shall not be subjected to radiant heat from chamber condi
14、tioning processes. The circulation of air within the chamber shall be sufficient to assure a no-load temperature uniformity of 5C. A temperature recorder and controller shall be provided, capable of controlling and recording the temperature within 2C at any setting throughout the temperature range.
15、3 Test specimen 3.1 Description A test specimen shall consist of a mated connector, unless otherwise specified in the referencing document. 3.2 Preparation 3.2.1 The test specimen shall be assembled with contacts and all accessories required for proper function of the specimen under test, unless oth
16、erwise specified in the referencing document. EIA/ECA-364-110 Page 2 3.2.2 The test specimen shall be tested in a terminated and mated state, unless otherwise specified in the referencing document. 3.2.3 When applicable the conductor lengths (directly terminated to the contacts or as attached to sup
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EIAECA3641102006TP110THERMALCYCLINGTESTPROCEDUREFORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-705006.html