ECA EIA-60384-26-2014 Fixed Capacitors for Use in Electronic Equipment - Part 26 Sectional Specification - Fixed Aluminium Electrolytic Capacitors with Conductive Polymer Solid Ele.pdf
《ECA EIA-60384-26-2014 Fixed Capacitors for Use in Electronic Equipment - Part 26 Sectional Specification - Fixed Aluminium Electrolytic Capacitors with Conductive Polymer Solid Ele.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-60384-26-2014 Fixed Capacitors for Use in Electronic Equipment - Part 26 Sectional Specification - Fixed Aluminium Electrolytic Capacitors with Conductive Polymer Solid Ele.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD Fixed Capacitors for Use in Electronic Equipment Part 26: Sectional Specification Fixed Aluminium Electrolytic Capacitors with Conductive Polymer Solid Electrolyte EIA-60384-26 (IEC 60384-26:2010, IDT) September 2014 ANSI/EIA-60384-26-2014 Approved: September 22, 2014 EIA-60384-26 NOTI
2、CE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay t
3、he proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publicatio
4、ns preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not
5、 assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is identical (IDT) with the International Standard IEC Publication 60384-26:2010: Fixed Capacitors for Use in Electronic Equipment Part 26: Section
6、al Specification Fixed Aluminium Electrolytic Capacitors with Conductive Polymer Solid Electrolyte. This document is the EIA Standard EIA-60384-26-2014 Edition 1: Fixed Capacitors for Use in Electronic Equipment Part 26: Sectional Specification Fixed Aluminium Electrolytic Capacitors with Conductive
7、 Polymer Solid Electrolyte. The text, figures and tables of IEC 60384-26:2010 are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted material has been reproduced with permission from ANSI. The IEC Foreword and Introduction are
8、not part of the requirements of this standard but are included for information purposes only. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriat
9、e safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5265, formulated under the cognizance of the P-2.5 Committee on EIA Solid Electrolytic Capacitors Standards and given final approval by the Standards Steering Commi
10、ttee for Passive Electronic Components Standards (S-1). Published by Electronic Components Industry Association 2014 Engineering Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permis
11、sion. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) i CONTENTS FOREWORD 1 1 Gene
12、ral . 3 1.1 Scope . 3 1.2 Object . 3 1.3 Normative references 3 1.4 Information to be given in a detail specification . 3 1.4.1 Outline drawings and dimensions 4 1.4.2 Mounting . 4 1.4.3 Rating and characteristics 4 1.4.4 Marking . 5 1.5 Terms and definitions 5 1.6 Marking . 5 1.6.1 General . 5 1.6.
13、2 Marking on capacitor 5 1.6.3 Marking on package . 5 1.6.4 Additional markings 5 2 Preferred rating and characteristics . 5 2.1 Preferred characteristics 5 2.1.1 Preferred climatic categories 6 2.2 Preferred values of ratings . 6 2.2.1 Nominal capacitance (CN) 6 2.2.2 Tolerance on nominal capacitan
14、ce 6 2.2.3 Rated voltage (UR) 6 2.2.4 Surge voltage 6 2.2.5 Rated temperature . 6 3 Quality assessment procedures 7 3.1 Primary stage of manufacture 7 3.2 Structurally similar components 7 3.3 Declaration of conformity (basic requirements) 7 3.4 Test schedule and requirement for initial assessment (
15、mandatory and optional tests) . 7 3.4.1 Qualification approval on the basis of the fixed sample size procedures sampling 7 3.4.2 Tests . 7 3.5 Quality conformance inspection 15 3.5.1 Formation of inspection lots 15 3.5.2 The schedule . 16 3.5.3 Delayed delivery 16 3.5.4 Assessment levels . 16 4 Test
16、 and measurement procedures . 18 4.1 Pre-conditioning (if required) 18 4.2 Measuring conditions . 18 4.3 Visual examination and check of dimensions. 19 4.3.1 Visual examination . 19 4.3.2 Requirements 19 4.4 Electrical tests . 19 ii 4.4.1 Leakage current . 19 4.4.2 Capacitance. 19 4.4.3 Tangent of l
17、oss angle (tan ) 20 4.4.4 Equivalent series resistance (ESR) . 20 4.5 Robustness of terminations 20 4.5.1 Initial measurement 20 4.6 Resistance to soldering heat 20 4.6.1 Initial measurement 20 4.6.2 Test conditions 20 4.6.3 Final inspection, measurements and requirements . 21 4.7 Solderability 21 4
18、.7.1 Test conditions 21 4.7.2 Final inspection, measurements and requirements . 21 4.8 Rapid change of temperature . 21 4.8.1 Initial measurement 21 4.8.2 Test conditions 21 4.8.3 Final inspection, measurements and requirements . 21 4.9 Vibration . 21 4.9.1 Test condition 22 4.9.2 Final inspection,
19、measurements and requirements . 22 4.10 Shock . 22 4.10.1 Test conditions 22 4.10.2 Final inspection, measurements and requirements . 22 4.11 Bump 22 4.11.1 Test conditions 22 4.11.2 Final examination, measurements and requirements 22 4.12 Climatic sequence . 22 4.12.1 Initial measurement 23 4.12.2
20、Dry heat 23 4.12.3 Damp heat, cyclic, Test Db, first cycle . 23 4.12.4 Cold 23 4.12.5 Damp heat, cyclic, Test Db, remaining cycles 23 4.12.6 Recovery . 23 4.12.7 Final inspection, measurements and requirements . 23 4.13 Damp heat, steady state 23 4.13.1 Initial measurement 23 4.13.2 Test conditions
21、23 4.13.3 Final inspection, measurements and requirements . 23 4.14 Endurance 23 4.14.1 Initial measurement 23 4.14.2 Test conditions 23 4.14.3 Final inspection, measurements and requirements . 24 4.15 Surge 24 4.15.1 Initial measurement 24 4.15.2 Test procedure . 24 4.15.3 Final inspection, measure
22、ments and requirements . 24 4.16 Reverse voltage (if required by the detail specification) . 24 4.16.1 Initial measurement 24 iii 4.16.2 Test procedure . 24 4.16.3 Final inspection, measurements and requirements . 25 4.17 Component solvent resistance (if required by the detail specification) 25 4.17
23、.1 Test conditions 25 4.18 Solvent resistance of the marking (if required by the detail specification) 25 4.18.1 Test conditions 25 4.19 Storage at high temperature . 25 4.19.1 Initial measurement 25 4.19.2 Test conditions 25 4.19.3 Final measurements and requirements 25 4.20 Characteristics at high
24、 and low temperature 25 4.20.1 Measurements and requirements 25 4.21 Charge and discharge (if required by the detail specification) 25 4.21.1 Initial measurement 26 4.21.2 Test procedure . 26 4.21.3 Final inspection, measurements and requirements . 26 4.22 High surge current (if required by the deta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA60384262014FIXEDCAPACITORSFORUSEINELECTRONICEQUIPMENTPART26SECTIONALSPECIFICATIONFIXEDALUMINIUMELECTROLYTICCAPACITORSWITHCONDUCTIVEPOLYMERSOLIDELEPDF

链接地址:http://www.mydoc123.com/p-704453.html