《DLA W-F-1814 65 D-2013 FUSE CARTRIDGE HIGH INTERRUPTING CAPACITY CLASSES RK1 AND RK5 (CURRENT-LIMITING) 600 VOLTS 101-200 AMPERES.pdf》由会员分享,可在线阅读,更多相关《DLA W-F-1814 65 D-2013 FUSE CARTRIDGE HIGH INTERRUPTING CAPACITY CLASSES RK1 AND RK5 (CURRENT-LIMITING) 600 VOLTS 101-200 AMPERES.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 5920 W-F-1814/65D 15 November 2013 SUPERSEDING W-F-1814/65C 20 November 2009 FEDERAL SPECIFICATION SHEET FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASSES RK1 AND RK5 (CURRENT-LIMITING) 600 VOLTS, 101-200 AMPERES The General Services Administration has authorized the use of this fed
2、eral specification sheet by all federal agencies. The complete requirements for procuring the fuses described herein shall consist of this document and the latest issue in effect of W-F-1814. Ltr Inches mm Ltr Inches mm Min Max Min Max Min Max Min Max A 9.620 9.630 244.34 244.60 G .433 .443 11.00 11
3、.25 B 1.375 (TYP) 34.93 (TYP) H - 1.970 - 50.04 C 6.125 6.781 155.58 172.24 J .183 .193 4.65 4.90 D .683 .693 17.35 17.60 K 1.125 (TYP) 28.58 (TYP) E .276 .286 7.01 7.26 L - 2.120 - 53.85 F 2.250 - 57.15 - M .979 .989 24.87 25.12 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given fo
4、r general information only. 3. Solid line indicates location, shape, and dimensions for minimum rejection groove. 4. Dashed line indicates location, shape, and dimensions for maximum rejection groove. 5. Unless otherwise specified, tolerances are .02 (0.51 mm) for two-place decimals and .005 (0.13 m
5、m) for three-place decimals. FIGURE 1. Classes RK1 and RK5 fuses, 600 volts, 101-200 amperes. INCH-POUND Provided by IHSNot for Resale-,-,-W-F-1814/65D 2 REQUIREMENTS: Interface and physical dimensions: See figure 1. Physical: Nonrenewable. Terminals: Knife blade type. Material: Copper, or copper al
6、loy. Strength: 5 inch-pound torque between body and blades. Body: Insulating material: Fiber, ceramic, melamine-impregnated glass fiber, or other suitable material. Electrical: Voltage: 600 volts or less. Frequency: 48 Hz to 60 Hz. Current: See table I. Current carrying capacity: 110 percent of rate
7、d current indefinitely with temperature rise not to exceed 50C (90F) above ambient on the body and 60C (108F) on the blades. Overload interrupt: Instantaneous: Shall interrupt within 2 hours at 135 percent of rated current and within 8 minutes at 200 percent of rated current. Time delay: In addition
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAWF181465D2013FUSECARTRIDGEHIGHINTERRUPTINGCAPACITYCLASSESRK1ANDRK5CURRENTLIMITING600VOLTS101200AMPERESPDF

链接地址:http://www.mydoc123.com/p-701589.html