DLA SMD-5962-01501 REV D-2007 MICROCIRCUIT HYBRID LINEAR 3 3-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路 3 3伏单通道直流-直流变换器》.pdf
《DLA SMD-5962-01501 REV D-2007 MICROCIRCUIT HYBRID LINEAR 3 3-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路 3 3伏单通道直流-直流变换器》.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-01501 REV D-2007 MICROCIRCUIT HYBRID LINEAR 3 3-VOLT SINGLE CHANNEL DC-DC CONVERTER《线性混合微电路 3 3伏单通道直流-直流变换器》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Added device type 02. Updated paragraph 4.3.5 to include RADHARD requirements. 01-10-26 Raymond Monnin B Add paragraph 1.5 and note 2. Table I, add note for enhanced low dose rate effects. Paragraph 4.3.5.a, correct paragraph to add component tes
2、ted dose rate. -sld 06-11-21 Raymond Monnin C Update Table I to include radiation level “L” for device type 02. Update table in paragraph 4.3.5 to include RHA level “L”. Add paragraph 3.2.3 for Radiation exposure circuit. 07-01-29 Joseph Rodenbeck D Added radiation hardened level P. -sld 07-06-04 Ro
3、bert M. Heber REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 PMIC N/A PREPARED BY Gary Zahn DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWI
4、NG IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Raymond Monnin AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 00-10-16 MICROCIRCUIT, HYBRID, LINEAR, 3.3-VOLT, SINGLE CHANNEL, DC-DC CONVERTER AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-01501 SHEET 1 OF 13 DSCC FORM 2
5、233 APR 97 5962-E438-07 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-01501 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This d
6、rawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in
7、 the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 01501 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardn
8、ess assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic
9、number Circuit function 01 MTR283R3S/883, MTR283R3SF/883 DC-DC converter, 20 W, +3.3 V output 02 SMTR283R3S, SMTR283R3SF DC-DC converter, 18 W, +3.3 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are d
10、efined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is inten
11、ded for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Ins
12、pections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) t
13、aken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality l
14、evel is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-01501 DEFENSE SUPPLY CENTER COLUMBUS COLUM
15、BUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 10 Dual-in-line Z See figure 1 10 Flange mount 1.2.5 Lead fini
16、sh. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range -0.5 V dc to +50 V dc Power dissipation (PD): Device types 01 and 02 (non-RHA) 12 W Device type 02 (RHA levels L and R) . 14 W Output power: Device type 01 (non-RHA) 20.6 W Device type 02
17、 (non-RHA) 18.5 W Device type 02 (RHA levels L and R) . 19.1 W Lead temperature (hand soldering, 10 seconds) +300C Storage temperature range -65C to +150C 1.4 Recommended operating conditions. Input voltage range +16 V dc to +40 V dc Case operating temperature range (TC) -55C to +125C 1.5 Radiation
18、features. Maximum total dose available (dose rate = 9 rad(Si)/s): Device type 02 (RHA levels L and R). 100 krad (Si) 2/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent spec
19、ified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircu
20、its. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ These parts may be dose rate sensitive in a
21、space enviroment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition C, tested at 9 rad(Si)/s.Provided by IHSNot for ResaleNo reproduction or networking
22、permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-01501 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standar
23、d Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a c
24、onflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596201501REVD2007MICROCIRCUITHYBRIDLINEAR33VOLTSINGLECHANNELDCDCCONVERTER 线性 混合 电路 33 通道 直流 变换器

链接地址:http://www.mydoc123.com/p-698195.html