《DLA A-A-59618-2002 CLEANER PRESSURE HOT-WATER SKID-MOUNTED [Superseded DLA XX-C-2866 CANC NOTICE 1 DLA XX-C-2866 NAVY MIL-C-29222 A CANC NOTICE 1 NAVY MIL-C-29222 A NAVY MIL-C-2922.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59618-2002 CLEANER PRESSURE HOT-WATER SKID-MOUNTED [Superseded DLA XX-C-2866 CANC NOTICE 1 DLA XX-C-2866 NAVY MIL-C-29222 A CANC NOTICE 1 NAVY MIL-C-29222 A NAVY MIL-C-2922.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH POUND A-A-59618 3 September 2002 SUPERSEDING XX-C-2866 5 January 2002 MIL-C-29222 31 July 1989 COMMERCIAL ITEM DESCRIPTION CLEANER, PRESSURE, HOT-WATER, SKID-MOUNTED The General Services Administration has authorized the use of this commercial item description (CID) for all federal agencies. 1
2、. SCOPE. This CID covers the general requirements for skid-mounted, hot water pressure cleaners. Pressure cleaners covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION. This CID uses a classification system that is included in the Part Identification Number (PIN
3、) as shown in the following example (see 7.1). AA59618 -X X X X CID number C = Solution container T = Solution tank 0 = No spare nozzles 1 = Spare nozzles 0 = No lifting and tie down attachments 1 = Lifting and tie down attachments 0 = No fungus resistance treatment 1 = Fungus resistance treatment E
4、xample PIN: AA59618-T100 is a cleaner with a solution tank and spare nozzles. 3. SALIENT CHARACTERISTICS. 3.1 Interface and physical dimensions. Pressure cleaners supplied to this CID shall be as specified herein. 3.2 Materials. All equipment, material, and articles incorporated in the work covered
5、by this specification are to be new and fabricated using materials produced from recovered materials to the maximum extent possible without jeopardizing the intended use. (See Section 4.) Unless otherwise specified, none of the above shall be interpreted to mean that the use of used or rebuilt produ
6、cts is allowed under this specification. 3.3 Performance. The cleaner shall be capable of continuous delivery of not less than 200 gph (760 Lph) of hot water at 180F (83C) at a minimum pressure of 1000 psig (6.90 MPa). The cleaner shall operate without excessive or undesirable vibration or pulsation
7、s. Valves shall close without causing water hammer. Cleaners shall not require frequent adjustment, suffer flame failure or erratic combustion, fail to maintain the specified operational pressures, or otherwise exhibit shutdowns or repeated malfunctions. Beneficial comments, recommendations, additio
8、ns, deletions, clarifications, etc., and any data which may improve this document should be sent to: Defense Supply Center, Columbus, ATTN: DSCC-VAI, Post Office Box 3990, Columbus OH 43216-5000, or telephone (614) 692-0538, or facsimile (FAX) (614) 692-6939. FSC 4940 DISTRIBUTION STATEMENT A. Appro
9、ved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59618 3.4 Design. The cleaner shall be UL 1776 certified and shall meet the requirements specified herein. The cleaner shall be designed and constr
10、ucted to withstand the normal shocks and stresses incident to transport by truck, air, sea, and rail. The design shall permit accessibility for maintenance and service of cleaners in the field. The cleaner shall be designed and equipped with a purge air connection to permit complete drainage of the
11、water from the heating coil, pump(s) and piping. Water and solution container shall be so designed and located as to prevent spillage or drainage on electrical equipment. 3.5 Safety. All mechanical or electrical parts that by their design or location may become a hazard to operating or maintenance p
12、ersonnel shall be enclosed or properly guarded. The cleaner noise level shall not exceed the value for an 8 h exposure as defined in 29 CFR 1910.95. 3.5.1 Controls. The cleaner shall be equipped with mechanical and electrical controls and devices necessary for safe and efficient operation. As a mini
13、mum, such controls shall include the following: a. Temperature control device to shut down the burner in the event the temperature of the heating coil exceeds a predetermined safe limit. b. Pressure control device to maintain the rated pressure in the heating coil and delivery hose. c. Automatic fue
14、l shutdown device to shut down fuel flow in the event of ignition interruption. d. A safety relief valve suitable for relieving overpressure before reaching a predetermined safe limit. 3.6 Heater section. The heater section shall consist essentially of a heating coil, a combustion chamber, and an oi
15、l burner. 3.6.1 Heating coil. The heating coil shall be continuous coiled seamless or welded carbon steel or alloy steel pipe or tubing having sufficient ductility for close coiling. The coil shall be capable of withstanding a hydrostatic test pressure of 2000 psi (13.8 MPa) for a period of at least
16、 2 min without any leakage or rupture. The nominal diameter of the tubing shall be at least 0.50 in (12.7 mm). The cleaner shall be equipped with accessible connections, fittings, and valves, as required, to permit coil blow down for the removal of scale deposits and sludge. The coil shall be design
17、ed and installed to allow for unequal expansion and contraction and to facilitate removal for soot cleaning, repair, or replacement. 3.6.2 Combustion chamber. The combustion chamber shall be of a preformed castable refractory; of a preformed ceramic fiber refractory; of a double, concentrically coil
18、ed, tangent tube water wall; or of a tangent tube water wall with metal liner. Both the castable and ceramic fiber refractories shall be rated to withstand exposure of the hot face to temperatures up to 2500 F (1370 C). 3.6.3 Oil burner. The oil burner shall be of the high-pressure mechanical atomiz
19、ing type or the low-pressure air atomizing type. The fuel system for mechanical atomizing burners shall include a positive displacement, electric motor driven fuel pump. Low-pressure burners shall include a fuel-metering device. Both type burners shall be equipped with high voltage electrode type sp
20、ark ignition and a forced draft blower. The burner firing cycle shall be thermostatically controlled to prevent excessive heating coil temperatures at reduced flow rates. The cleaner shall be equipped with a fuel tank having a minimum capacity for 2 h continuous operation. The burner shall be capabl
21、e of continuous operation at full rated capacity with a smoke density reading not to exceed ASTM D2156 Smoke Spot Number 2. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59618 The burner shall be suitable for firing any of the following fuel:
22、 a. Fuel oil, grade No. 2. b. Diesel fuel, grades DF-1 and DF-2. c. Jet fuel, grade JP-8. 3.7 Water pump. The pump shall be a positive displacement, electric motor driven packed plunger type. Pump check valves, including disk or balls, springs, seats, and any other associated metallic parts, shall b
23、e resistant to the corrosive effects of the cleaning compound and coil descaling acid solutions. Pump bearings shall be of the sealed, permanently lubricated type or shall run in an oil bath. 3.7.1 Damping device. The pump or piping connected thereto shall be equipped with a damping device to absorb
24、 pressure pulsations caused by the reciprocating action of the pump. 3.7.2 Water tank. A water tank with a constant-level float valve shall be provided to act as a reservoir for the incoming water supply. The tank shall be fabricated of corrosion resistant metal or metal treated to resist corrosion
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA596182002CLEANERPRESSUREHOTWATERSKIDMOUNTEDSUPERSEDEDDLAXXC2866CANCNOTICE1DLAXXC2866NAVYMILC29222ACANCNOTICE1NAVYMILC29222ANAVYMILC2922PDF

链接地址:http://www.mydoc123.com/p-687613.html