DIN EN ISO 11140-4-2007 Sterilization of health care products - Chemical indicators - Part 4 Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of s.pdf
《DIN EN ISO 11140-4-2007 Sterilization of health care products - Chemical indicators - Part 4 Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of s.pdf》由会员分享,可在线阅读,更多相关《DIN EN ISO 11140-4-2007 Sterilization of health care products - Chemical indicators - Part 4 Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of s.pdf(43页珍藏版)》请在麦多课文档分享上搜索。
1、July 2007DEUTSCHE NORM English price group 17No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 11.080.20!,yh%“9866902www
2、.din.deDDIN EN ISO 11140-4Sterilization of health care products Chemical indicators Part 4: Class 2 indicators as an alternative to the Bowie and Dick-typetest for detection of steam penetration (ISO 11140-4:2007)English version of DIN EN ISO 11140-4:2007-07Sterilisation von Produkten fr die Gesundh
3、eitsvorsorge Chemische Indikatoren Teil 4: Indikatoren der Klasse 2, die alternativ zum Bowie-Dick-Test fr den Nachweis derDampfdurchdringung verwendet werden (ISO 11140-4:2007)Englische Fassung DIN EN ISO 11140-4:2007-07SupersedesDIN EN 867-4:2001-02www.beuth.deDocument comprises 43 pages09.07DIN E
4、N ISO 11140-4:2007-07 2 National foreword This standard has been prepared by Technical Committee ISO/TC 198 “Sterilization of health care products” in collaboration with Technical Committee CEN/TC 102 “Sterilizers for medical purposes” (Secretariat: DIN, Germany). The responsible German body involve
5、d in its preparation was the Normenausschuss Medizin (Medical Standards Committee), Technical Committee NA 063-04-08 AA Indikatoren. DIN EN ISO 11140 consists of the following parts under the general title Sterilization of health care products Chemical indicators1): Part 1: General requirements Part
6、 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration In addition, reference is made to DIN EN 867-5, Non-biological systems for use in sterilizers Part 5
7、: Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers type B and type S, which is intended to be revised under the Vienna Agreement. The test method described by Bowie in 1963 is carried out throughout the world in many variations. T
8、o detect steam penetration within the context of ISO 17665-1, two variations are possible: the Bowie and Dick test as described in EN 285:2006 and the alternative test (“Bowie and Dick-type test”) specified in this part of DIN EN ISO 11140. The Bowie and Dick test as in EN 285:2006 requires the use
9、of a standard test pack or a reduced test pack with an indicator as in Part 3 of DIN EN ISO 11140. The alternative test described here gives the same results when carried out under the specified conditions. The DIN Standards corresponding to the International Standards referred to in clause 2 and in
10、 the bibliography of the EN are as follows: IEC 60584-2 DIN IEC 60584-2 IEC 60751 DIN IEC 60751 ISO 187 DIN EN 20187 ISO 2248 DIN EN 22248 ISO 9001 DIN EN ISO 9001 ISO 10012-1 DIN EN ISO 10012 ISO 11140-1 DIN EN ISO 11140-1 ISO 11140-3 DIN EN ISO 11140-3 ISO 15882 DIN EN ISO 15882 ISO 17665-1 DIN EN
11、 ISO 17665-1 1) ISO 11140-2:1998, Test equipment and methods, has been withdrawn and superseded by ISO 18472:2006, Sterilization of health care products Biological and chemical indicators Test equipment. ISO 11140-5:2000, Class 2 indicators for Bowie and Dick-type air removal tests, has not been ado
12、pted by CEN as a European Standard. DIN EN ISO 11140-4:2007-07 3 Amendments This standard differs from DIN EN 867-4:2001-02 as follows: a) In the scope, the indicator class designation has been harmonized with the new designation system specified in DIN EN ISO 11140-1. Thus, “Class B indicators” are
13、 now referred to as “Class 2 indicators”. b) Now only six temperature sensors are required, rather than twelve. c) In the description of air removal by trans-atmospheric pulsing, requirements for any air injection system used are no longer specified. d) An ultimate pressure of 5 kPa has been specifi
14、ed for the evacuation of the chamber of the steam exposure apparatus. e) In Annex C, an illuminant has been specified for the apparatus. f) Requirements for the air injection system have been modified. g) The standard has been editorially revised. Previous editions DIN EN 867-4: 2001-02 National Ann
15、ex NA (informative) Bibliography DIN EN 20187, Paper, board and pulps Standard atmosphere for conditioning and testing and procedure for monitoring the atmosphere and conditioning of samples DIN EN 22248, Packaging Complete, filled transport packages Vertical impact test by dropping DIN EN ISO 9001,
16、 Quality management systems Requirements DIN EN ISO 10012, Measurement management systems Requirements for measurement processes and measuring equipment DIN EN ISO 11140-1, Sterilization of health care products Chemical indicators Part 1: General requirements DIN EN ISO 11140-3, Sterilization of hea
17、lth care products Chemical indicators Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test DIN EN ISO 15882, Sterilization of health care products Chemical indicators Guidance for selection, use and interpretation of results DIN EN ISO 17665-1, Sterilization of
18、 health care products Moist heat Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices DIN IEC 60584-2, Thermocouples Part 2: Tolerances DIN IEC 60751, Industrial platinum resistance thermometer sensors DIN EN ISO 11140-4:2007-07 4 Th
19、is page is intentionally blank EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 11140-4March 2007ICS 11.080.01 Supersedes EN 867-4:2000 English VersionSterilization of health care products - Chemical indicators - Part 4:type test for detection of steam penetration (ISO 11140-4:2007)Strilisation
20、 des produits de sant - Indicateurs chimiques -Partie 4: Indicateurs de Classe 2 comme alternative lessai de Bowie et Dick pour la dtection de la pntrationde la vapeur (ISO 11140-4:2007)Sterilisation von Produkten fr die Gesundheitsfrsorge -Chemische Indikatoren - Teil 4: Indikatoren der Klasse 2,di
21、e alternativ zum Bowie-Dick-Test fr den Nachweis derDampfdurchdringung verwendet werdenThis European Standard was approved by CEN on 14 March 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a
22、 national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version
23、in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
24、Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROP
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINENISO1114042007STERILIZATIONOFHEALTHCAREPRODUCTSCHEMICALINDICATORSPART4CLASS2INDICATORSASANALTERNATIVETOTHEBOWIEANDDICKTYPETESTFORDETECTIONOFSPDF

链接地址:http://www.mydoc123.com/p-678801.html