《DIN EN 28050-1992 Ferronickel ingots or pieces sampling for analysis (ISO 8050 1988) german version EN 28050 1992《镍铁锭和镍铁块 分析取样》.pdf》由会员分享,可在线阅读,更多相关《DIN EN 28050-1992 Ferronickel ingots or pieces sampling for analysis (ISO 8050 1988) german version EN 28050 1992《镍铁锭和镍铁块 分析取样》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Ferronickel ingots or pieces Sampling for analysis (IS0 8050 : 1988) Enalich version of DIN EN 28050 DIN - I EN 28050 This standard incorporates the English version of Is0 8050. Ferronickelbarren oder -stcke; Probennahme fr Analyse (IS0 8050 : 1988) European Standard EN 28 050 : 1988 has the status
2、of a DIN Standard. A comma is used as the decimal marker. National foreword This standard has been published in accordance with a decision taken by CEN/BT to adopt, without alteration, Interna- tional Standard IS0 8050 : 1988 as a European Standard. The responsible German body involved in the prepar
3、ation of this standard was the Normenausschu Nichteisenmetalle (Nonferrous Metals Standards Committee). The DIN Standards corresponding to the International Standards referred to in clause 2 of the EN are as follows: IS0 6352 IS0 6501 DIN EN 26 352 DIN EN 26 501 Standards referred to (and not includ
4、ed in Normative references) DIN EN 26 532 Ferronickel; determination of nickel content; gravimetric method using dimethylglyoxim (IS0 6352 : 1985) DIN EN 26 501 Ferronickel; specification and delivery requirements (IS0 6501 : 1988) International Patent Classification 823 B 35/00 B23 B 47/34 B23C 3/0
5、0 GO1 N 1/00 G O1 N 33/20 EN comprises 18 pages. Beurh Verlag GmbH, Berlin, has the exclusive right of sale for German Standards (DIN-Normen). DIN EN 28050 Engl. Price group 12 05.93 Sales No. 1112 EUROPEAN STANDARD EUROPISCHE NORM NORME EUROPENNE EN 28 050 May 1992 UDC 669.1524-198-4: 620.11 Descri
6、ptors: Ferroalloys, ferronickel, ingots, sampling, samples. English version Ferronickel ingots or pieces Sampling for analysis (IS0 8050 : 1988) Ferro-nickel en lingots ou en morceaux; chantillonage pour analyse (IS0 8050 : 1988) Ferronickelbarren oder -stcke; Probennahme fr Analyse (IS0 8050: 1988)
7、 This European Standard was approved by CEN on 1992-05-08 and is identical to the IS0 Standard as referred to. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alte
8、ration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A ver- sion in any other language made by tra
9、nslation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the offi- cial versions. CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxem
10、bourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom CEN European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Central Secretariat: rue de Stassart 36, 6-1050 Brussels O 1992. Copyright reserved to all CEN members. Ref. No
11、. EN 28050:1992 E Page 2 EN 28050:1992 foreword On the proposal of the CEN Central Secretariat, CEN/BT decided by Resolution BT C157/1990 to submit International Standard IS0 8050: 1988 to Formal Vote. The result was positive. In the countries bound to implement this European Standard, a national st
12、andard identical to this European Standard shall be published, and conflicting national standards withdrawn, by 1992-11 -30 at the latest. In accordance with the CEN/CENELEC Internal Regulations, the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finlan
13、d, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Ferronickel ingots; sampling for analysis Endorsement notice The text of the International Standard IS0 8050: 1988 was approved by CEN as a European Standard
14、 without any modifica- tion. Page 3 EN 28 050 : 1992 1 Scope This International Standard specifies a method for sampling of ferronickel lots in ingot or piece form with a View to obtaining a representative laboratory sample for the determination of the chemical composition of the lot. As agreed betw
15、een the purchaser and the supplier, a choice is to be made between two procedures: - The first procedure can be applied at the producers plant during casting (description in clauses 3 and 51. - The second procedure can be applied to lots as delivered at the buyers premises“ (description in clauses 4
16、 and 5). It includes two alternatives for sample taking (drill- ing and milling). Each party is entitled to participate in lor be represented at) sampling operations. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of thi
17、s International Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this International Standard are encour- aged to investigate the possibility of applying the most recent editions of the standards listed
18、below. Members of IEC and IS0 maintain registers of currently valid International Standards. IS0 513 : 1975, Appliwtion of wrbides for machining by chip removal - Designation of the main groups of chip removal and groups of application. IS0 3855 : iS, Milling cutters - Nomenclature. IS0 4957 : 1980,
19、 Tool steels. IS0 6352 : 1985, Ferronickel - Determination of nickel content - Dimethylglyoxime gravimetric method. IS0 651 : 1988, Ferronickel - Specifications and conditions of detivev. 3 Sampling of each heat at the producers plant 3.1 Taking the primary sample during casting 3.1.1 Each increment
20、2) shall be taken using a spoon and cast in a mould to obtain a suitable small ingot for chemical or physical analysis. The usual geometry of such ingots is that of a frustum. It is desirable that the dimensions lie within the follow- ing limits: - height: 100 to 140 mm - upper diameter: 35 to 50 mm
21、 - lower diameter: 30 to 40 mm The ingot mould shall be made of material that allows the sample to cod rapidly; a large block of copper would meet this requirement. If necessary, the sample shall be killed to obtain a small ingot of sound metal (free of cracks and blowholes). Killing is most often d
22、one with aluminium, in wire or chip form, at 1 to 2 g of aluminium per kilogram. The large height of the small ingots permits small shrinkholes to be confined to the upper part, thus ensuring that the lower part of the ingot is perfectly sound and homogenous and hence suitable for analysis. Generall
23、y, a height of 120 mm will guarantee that the sound portion extends at least 70 mm up from the base. 3.1.2 In general, the small ingots are used for physical analysis on solid metal after a disc is cut from them. Whenever possible, this analysis should produce results as ac- curate as those obtained
24、 from chemical analysis of chips. To achieve such accuracy, it is often necessary to analyse several small ingots several times each. A specified number of small ingots shall therefore be taken at regularly spaced intervals during the casting. Examples are given in annex A to indicate the number of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN280501992FERRONICKELINGOTSORPIECESSAMPLINGFORANALYSISISO80501988GERMANVERSIONEN280501992 镍铁锭 铁块

链接地址:http://www.mydoc123.com/p-673399.html