DIN EN 54-29-2015 Fire detection and fire alarm systems - Part 29 Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors German version EN 54-2.pdf
《DIN EN 54-29-2015 Fire detection and fire alarm systems - Part 29 Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors German version EN 54-2.pdf》由会员分享,可在线阅读,更多相关《DIN EN 54-29-2015 Fire detection and fire alarm systems - Part 29 Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors German version EN 54-2.pdf(100页珍藏版)》请在麦多课文档分享上搜索。
1、June 2015 Translation by DIN-Sprachendienst.English price group 31No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 1
2、3.220.20!%Ck“2322772www.din.deDDIN EN 54-29Fire detection and fire alarm systems Part 29: Multi-sensor fire detectors Point detectors using a combination of smoke and heat sensors;English version EN 54-29:2015,English translation of DIN EN 54-29:2015-06Brandmeldeanlagen Teil 29: Mehrfachsensor-Brand
3、melder Punktfrmige Melder mit kombinierten Rauch- und Wrmesensoren;Englische Fassung EN 54-29:2015,Englische bersetzung von DIN EN 54-29:2015-06Systmes de dtection et dalarme incendie Partie 29: Dtecteurs dincendie multi-capteurs Dtecteurs ponctuels utilisant une combinaison de capteurs de fume et d
4、e chaleur;Version anglaise EN 54-29:2015,Traduction anglaise de DIN EN 54-29:2015-06See start of applicationwww.beuth.deDocument comprises 100 pagesIn case of doubt, the German-language original shall be considered authoritative.05.15 DIN EN 54-29:2015-06 2 A comma is used as the decimal marker. Sta
5、rt of application The start of application of this standard is 2015-06-01. It should be noted that, in Germany, CE conformity marking of construction products will be permitted once this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal
6、Gazette) and from the date given therein. For further information, users of this standard should refer to the websites of the European Commission or of the relevant building authority. National foreword This document (EN 54-29:2015) has been prepared by Technical Committee CEN/TC 72 “Fire detection
7、and fire alarm systems” (Secretariat: BSI, United Kingdom). The responsible German body involved in its preparation was the DIN-Normenausschuss Feuerwehrwesen (DIN Standards Committee Firefighting and Fire Protection), Working Group NA 031-02-01-08 AK Brandmelder Gruppe A of Working Committee NA 031
8、-02-01 AA Brandmelde- und Feueralarmanlagen. This European product standard specifies requirements for multi-sensor fire detectors Point detectors using a combination of smoke and heat sensors for use in fire detection and alarm systems permanently installed in buildings (referred to in German as “B
9、MS” and “BMA” equipment). The system requirements and technical application rules for fire detection and fire alarm systems complying with this standard are specified in DIN 14675 and DIN VDE 0833-2 (VDE 0833-2). Certification of conformity of these products with the requirements specified in this E
10、uropean Standard is based on conformity evaluation of the products carried out by “Notified Bodies” in accordance with the EU Directive No. 305/2011 (see Annex ZA). It should be noted that, in Germany, smoke detection and the corresponding activation of fire protection dampers are to meet the requir
11、ements for building inspectorate approval by the Deutsches Institut fr Bautechnik (DIBt) (German Building Institute). DIN EN 54-29:2015-06 3 National Annex NA (informative) Bibliography DIN 14675, Fire detection and fire alarm systems Design and operation DIN VDE 0833-2 (VDE 0833-2), Alarm systems f
12、or fire, intrusion and hold up Part 2: Requirements for fire alarm systems EUV 305/2011, Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC D
13、IN EN 54-29:2015-06 4 This page is intentionally blank EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-29 April 2015 ICS 13.220.20 English Version Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors Syst
14、mes de dtection et dalarme incendie - Partie 29 : Dtecteurs dincendie multi-capteurs - Dtecteurs ponctuelsutilisant une combinaison de capteurs de fume et de chaleur Brandmeldeanlagen - Teil 29: Mehrfachsensor-Brandmelder - Punktfrmige Melder mit kombinierten Rauch- und Wrmesensoren This European St
15、andard was approved by CEN on 15 February 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concern
16、ing such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into
17、its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Ger
18、many, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE F
19、R NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 54-29:2015 EEN 54-29:2015 (E) 2 Contents Page Foreword 6 Introduction .8 1 Scope 9 2 Normative referenc
20、es 9 3 Terms and definitions 10 4 Requirements 10 4.1 General . 10 4.2 Nominal activation conditions/sensitivity 10 4.2.1 Individual alarm indication 10 4.2.2 Response to slowly developing fires 10 4.2.3 Repeatability of smoke response 11 4.2.4 Directional dependence of smoke response . 11 4.2.5 Dir
21、ectional dependence of heat response . 11 4.2.6 Lower limit of heat response . 11 4.2.7 Reproducibility of smoke response 11 4.2.8 Reproducibility of heat response 11 4.2.9 Air movement 11 4.2.10 Dazzling . 11 4.3 Operational reliability . 11 4.3.1 Connection of ancillary devices 11 4.3.2 Monitoring
22、 of detachable detectors 11 4.3.3 Manufacturers adjustments 12 4.3.4 On-site adjustment of response behaviour . 12 4.3.5 Protection against the ingress of foreign bodies 12 4.3.6 Software controlled detectors . 12 4.4 Tolerance to supply parameters . 13 4.4.1 Variation in supply parameters . 13 4.5
23、Performance parameters under fire conditions 14 4.5.1 Fire sensitivity . 14 4.6 Durability of nominal activation conditions/sensitivity 14 4.6.1 Temperature resistance . 14 4.6.2 Humidity resistance 14 4.6.3 Shock and vibration resistance . 14 4.6.4 Electrical stability . 15 4.6.5 Resistance to chem
24、ical agents . 15 5 Test and assessment and sampling methods . 15 5.1 General . 15 5.1.1 Atmospheric conditions for tests . 15 5.1.2 Operating conditions for tests 15 5.1.3 Mounting arrangements . 15 5.1.4 Tolerances . 16 5.1.5 Measurement of smoke response value 16 5.1.6 Measurement of heat response
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN54292015FIREDETECTIONANDFIREALARMSYSTEMSPART29MULTISENSORFIREDETECTORSPOINTDETECTORSUSINGACOMBINATIONOFSMOKEANDHEATSENSORSGERMANVERSIONEN542PDF

链接地址:http://www.mydoc123.com/p-671652.html