BS EN 62439-5-2010 Industrial communication networks - High availability automation networks - Beacon redundancy protocol (BRP)《工业通信网络 高可靠性自动化网络 信标备用协议(BRP)》.pdf
《BS EN 62439-5-2010 Industrial communication networks - High availability automation networks - Beacon redundancy protocol (BRP)《工业通信网络 高可靠性自动化网络 信标备用协议(BRP)》.pdf》由会员分享,可在线阅读,更多相关《BS EN 62439-5-2010 Industrial communication networks - High availability automation networks - Beacon redundancy protocol (BRP)《工业通信网络 高可靠性自动化网络 信标备用协议(BRP)》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationIndustrial communication networks High availabilityautomation networksPart 5: Beacon Redundancy Protocol (BRP)BS EN 62439-5:2010National forewordThis British Standard is the UK i
2、mplementation of EN 62439-5:2010. It isidentical to IEC 62439-5:2010. Together with BS EN 62439-1:2010, BS EN 62439-2:2010, BS EN 62439-3:2010, BS EN 62439-4:2010 and BS EN 62439-6:2010, it supersedes BS EN 62439:2008 which is withdrawn.The UK participation in its preparation was entrusted to Techni
3、cal CommitteeAMT/7, Industrial communications: process measurement and control,including fieldbus.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are respons
4、ible for its correct application. BSI 2010ISBN 978 0 580 70829 9ICS 25.040.40; 35.040; 35.110Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 June 2010.Amendment
5、s issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62439-5:2010EUROPEAN STANDARD EN 62439-5 NORME EUROPENNE EUROPISCHE NORM March 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektr
6、otechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62439-5:2010 E ICS 25.040; 35.040 Supersedes EN 62439:2008 (partially)English version Industrial com
7、munication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP) (IEC 62439-5:2010) Rseaux de communication industrielle - Rseaux dautomatisme haute disponibilit - Partie 5 :Protocole de redondance balise (BRP) (CEI 62439-5:2010) Industrielle Kommunikationsnetze
8、 - Hochverfgbare Automatisierungsnetze - Teil 5: Funkbaken-Redundanz-Protokoll (BRP) (IEC 62439-5:2010) This European Standard was approved by CENELEC on 2010-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
9、Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English,
10、 French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belg
11、ium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. B
12、S EN 62439-5:2010EN 62439-5:2010 - 2 - Foreword The text of document 65C/583/FDIS, future edition 1 of IEC 62439-5, prepared by SC 65C, Industrial networks, of IEC TC 65, Industrial-process measurement, control and automation, was submitted to the IEC-CENELEC parallel vote and was approved by CENELE
13、C as EN 62439-5 on 2010-03-01. This EN 62439-5 together with EN 62439-1, EN 62439-2, EN 62439-3, EN 62439-4 and EN 62439-6 supersedes EN 62439:2008. EN 62439-5:2010 includes the following significant technical changes with respect to EN 62439:2008: adding a calculation method for RSTP (rapid spannin
14、g tree protocol, IEEE 802.1Q), adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol), moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to EN 62439-1, whi
15、ch serves now as a base for the other documents, moving Clause 5 (MRP) to EN 62439-2 with minor editorial changes, moving Clause 6 (PRP) was to EN 62439-3 with minor editorial changes, moving Clause 7 (CRP) was to EN 62439-4 with minor editorial changes, and moving Clause 8 (BRP) was to EN 62439-5 w
16、ith minor editorial changes, adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to EN 62439-1 as Clause 8, adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to EN 62439-3 as Clause 5,
17、 and introducing the DRP protocol as EN 62439-6. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest d
18、ate by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-03-01 Annex ZA has been added by CENELEC. _ BS EN 62439-
19、5:2010- 3 - EN 62439-5:2010 Endorsement notice The text of the International Standard IEC 62439-5:2010 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61158 serie
20、s NOTE Harmonized in EN 61158 series (not modified). IEC 62439-2 NOTE Harmonized as EN 62439-2. IEC 62439-3 NOTE Harmonized as EN 62439-3. IEC 62439-4 NOTE Harmonized as EN 62439-4. IEC 62439-6 NOTE Harmonized as EN 62439-6. BS EN 62439-5:2010EN 62439-5:2010 - 4 - Annex ZA (normative) Normative refe
21、rences to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (
22、including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-191 - International Electrotechnical Vocabulary (IEV) - Chapter 191: Dependability and qual
23、ity of service - - IEC 62439-1 2010 Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods EN 62439-1 2010 ISO/IEC/TR 8802-1 - Information technology - Telecommunications and information exchange between systems - Local and metrop
24、olitan area networks - Specific requirements - Part 1: Overview of Local Area Network Standards - - ISO/IEC 8802-3 2000 Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6243952010INDUSTRIALCOMMUNICATIONNETWORKSHIGHAVAILABILITYAUTOMATIONNETWORKSBEACONREDUNDANCYPROTOCOLBRP

链接地址:http://www.mydoc123.com/p-578480.html