BS EN 50578-2013 Railways applications Direct current signalling relays《铁路应用设施 直流电传递信号继电器》.pdf
《BS EN 50578-2013 Railways applications Direct current signalling relays《铁路应用设施 直流电传递信号继电器》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50578-2013 Railways applications Direct current signalling relays《铁路应用设施 直流电传递信号继电器》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50578:2013Railways applications Directcurrent signalling relaysBS EN 50578:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50578:2013.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/9/1, Railway
2、 Electrotechnical Applications -Signalling and communications.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The
3、 British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 75609 2ICS 93.100Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June
4、2013.Amendments issued since publicationDate Text affectedBS EN 50578:2013EUROPEAN STANDARD EN 50578 NORME EUROPENNE EUROPISCHE NORM June 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Norm
5、ung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50578:2013 E ICS 93.100 English version Railways applications - Direct current signalling relays Applications ferrovia
6、ires - Relais de signalisation courant continu Bahnanwendungen - Gleichstrom-Signalrelais This European Standard was approved by CENELEC on 2013-05-20. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the s
7、tatus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, Fre
8、nch, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria
9、, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
10、Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50578:2013EN 50578:2013 - 2 - Contents Foreword 3 Introduction 4 1 Scope 5 2 Normative references . . 5 3 Terms and definitions. . 5 4 Classification 7 5 Essential requirements of the relays and their construction . . 8 5.1 Generic requiremen
11、ts for signalling relays . . 8 5.1.1 Forcibly guided (mechanically linked) contacts . 8 5.1.2 Forcibly guided (mechanically linked) operation . 8 5.2 Specific requirements . . 8 5.2.1 Relays of type N . . 8 5.2.2 Relays of type C . . 8 5.3 Mechanical construction of the signalling relays . . 9 5.3.1
12、 Connecting devices . 9 5.3.2 Materials . 9 5.4 Environmental conditions . 9 5.4.1 General . 9 5.4.2 Vibrations and shocks . 9 5.5 Magnetic system . . 9 5.5.1 General . 9 5.5.2 Requirements for new relays . . 9 5.5.3 Functioning during service . . 10 5.6 Design of insulation . 10 5.6.1 General . 10
13、5.6.2 Overvoltage . 10 5.6.3 Test voltage . . 11 5.6.4 Case of a supply circuit not connected to earth . . 11 5.6.5 Pollution . . 11 5.7 Contacts . 11 5.7.1 Spacing . 11 5.7.2 Break contact . . 11 5.7.3 Contact heating . 11 5.7.4 Service life . . 11 5.7.5 Minimum distance apart of the relay contact
14、elements. 12 5.7.6 Contact force . . 12 5.7.7 Self-cleaning . 12 5.7.8 Bounce . . 12 Bibliography . 13 BS EN 50578:2013- 3 - EN 50578:2013 Foreword This document (EN 50578:2013) has been prepared by SC 9XA, “Communication, signalling andprocessing systems“, of Technical Committee CENELEC TC 9X, “Ele
15、ctrical and electronic applicationsfor railways“. The following dates are fixed: latest date by which this document has to be implemented at national level bypublication of an identical national standard or by endorsement (dop) 2014-05-20 latest date by which the national standards conflicting with
16、this document have to be withdrawn (dow) 2016-05-20 This document is a transposition of the UIC leaflet 736, Signalling relays. Attention is drawn to the possibility that some of the elements of this document may be the subject ofpatent rights. CENELEC and/or CEN shall not be held responsible for id
17、entifying any or all suchpatent rights. BS EN 50578:2013EN 50578:2013 - 4 - Introduction This European Standard gives a set of generic and specific requirements for direct current signallingrelays. This European Standard introduces a set of recommendations and requirements for signalling relaycharac
18、teristics, construction, magnetic system, contacts and insulation. Requirements are coordinatedwith present international standards on all-or-nothing relays. BS EN 50578:2013- 5 - EN 50578:2013 1 Scope This European Standard gives requirements for direct current relays intended for safety-relatedapp
19、lications in railway signalling installations. This European Standard is applicable to monostable relays. However it can also be used as a guide forother relays such as with bistable relays. 2 Normative references The following documents, in whole or in part, are normatively referenced in this docum
20、ent and areindispensable for its application. For dated references, only the edition cited applies. For undatedreferences, the latest edition of the referenced document (including any amendments) applies. EN 50124-1, Railway applications Insulation coordination Part 1: Basic requirements Clearances
21、and creepage distances for all electrical and electronic equipment EN 50125-3:2003, Railway applications Environmental conditions for equipment Part 3:Equipment for signalling and telecommunications EN 60664-1, Insulation coordination for equipment within low-voltage systems Part 1: Principles,requi
22、rements and tests (IEC 60664-1) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 all-or-nothing relay electrical relay, which is intended to be energised by a quantity, the value of which is either within itsoperative range or effectively zero
23、 Note 1 to entry: “All-or-nothing relays“ include both “elementary relays“ and “time relays“. SOURCE: IEC 60050-444:2002, 444-01-02 3.2 armature moveable part of a relay that controls contact members 3.3 bistable relay electrical relay which, having responded to an energising quantity and having cha
24、nged its condition,remains in that condition after the quantity has been removed; a further appropriate energisation isrequired to make it change its condition SOURCE: IEC 60050-444:2002, 444-01-08 3.4 bounce time for a contact which is closing/opening its circuit, time interval between the instant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN505782013RAILWAYSAPPLICATIONSDIRECTCURRENTSIGNALLINGRELAYS 铁路 应用 设施 直流 电传递 信号 继电器 PDF

链接地址:http://www.mydoc123.com/p-575050.html