BS EN 50306-2-2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Single core cables《轨道交通 有专门防火性能的铁路机车车辆电缆 薄壁 单芯电缆》.pdf
《BS EN 50306-2-2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Single core cables《轨道交通 有专门防火性能的铁路机车车辆电缆 薄壁 单芯电缆》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50306-2-2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Single core cables《轨道交通 有专门防火性能的铁路机车车辆电缆 薄壁 单芯电缆》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50306-2:2002 Railway applications Railway rolling stock cables having special fire performance Thin wall Part 2: Single core cables The European Standard EN 50306-2:2002 has the status of a British Standard ICS 13.220.40; 45.060.01 BS EN 50306-2:2002 This British Standard, hav
2、ing been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 13 November 2002 BSI 13 November 2002 ISBN 0 580 40742 X National foreword This British Standard is the official Eng
3、lish language version of EN 50306-2:2002. The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electrical cables, to Subcommittee GEL/20/12, Railway cables, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on re
4、quest to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI
5、 Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirer
6、s to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This documen
7、t comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 503
8、06-2 NORME EUROPENNE EUROPISCHE NORM October 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of e
9、xploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50306-2:2002 E ICS 13.220.40; 45.060.01 English version Railway applications - Railway rolling stock cables having special fire performance - Thin wall Part 2: Single core cables Applications ferroviaires -
10、Cbles pour matriel roulant ferroviaire ayant des performances particulires de comportement au feu - Isolation mince Partie 2: Cbles monoconducteurs Bahnanwendungen - Kabel und Leitungen fr Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Reduzierte Isolierwanddicken Teil 2: Einadrige Kabe
11、l und Leitungen This European Standard was approved by CENELEC on 2002-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and
12、bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsi
13、bility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Irelan
14、d, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.EN 50306-2:2002 - 2 - Foreword This European Standard was prepared by Working Group 12, Railway cables, of Technical Committee CENELEC TC 20, Electric cables, as part of the overall pr
15、ogramme of work in CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50306-2 on 2002-06-01. The following dates were fixed: - latest date by which the EN has to be implemented a
16、t national level by publication of an identical national standard or by endorsement (dop) 2003-07-01 - latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-07-01 Annexes designated “informative” are given for information only. In this standard, annexes
17、A and B are informative. _- 3 - EN 50306-2:2002 Contents Introduction 4 1 Scope 4 2 Normative references.5 3 Single core cables .6 4 Tests8 Annex A (informative) Guidance on selection of cables for type approval 16 Annex B (informative) Bibliography 16 Table 1 - Requirements for construction 8 Table
18、 2 - Test requirements .10 Table 3 - Pliability test requirements.13 Table 4 - Schedule of tests.15EN 50306-2:2002 - 4 - Introduction EN 50306 covers a range of sheathed and unsheathed cables with thin wall thickness insulation, based on halogen-free materials, for use in railway rolling stock. It i
19、s divided into four parts: Part 1: General requirements; Part 2: Single core cables; Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed; Part 4: Multicore and multipair cables standard wall sheathed. Special test methods referred to in EN 50306 are gi
20、ven in EN 50305. A guide to use is given in EN 50355 1) . The cables in EN 50306-2 are also required in other parts of this series of standards to build up cables with additional screening and sheathing and also in multicore and multipair combinations. EN 50306-1, General requirements, contains a mo
21、re extensive introduction to EN 50306 and should be read in conjunction with this European Standard. 1 Scope EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm 2to 2,5 mm 2single core) All ca
22、bles have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 C, and a maximum tem
23、perature for short-circuit conditions of 160 C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 C for 105 C are
24、defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to sati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5030622002RAILWAYAPPLICATIONSRAILWAYROLLINGSTOCKCABLESHAVINGSPECIALFIREPERFORMANCETHINWALLSINGLECORECABLES

链接地址:http://www.mydoc123.com/p-574781.html