BS EN 50299-2002 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72 5 kV to 550 kV《UDOWNm设备的最高电压从72 5 kV - 550 k.pdf
《BS EN 50299-2002 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72 5 kV to 550 kV《UDOWNm设备的最高电压从72 5 kV - 550 k.pdf》由会员分享,可在线阅读,更多相关《BS EN 50299-2002 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72 5 kV to 550 kV《UDOWNm设备的最高电压从72 5 kV - 550 k.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50299:2002 Incorporating Corrigendum No. 1 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment U mfrom 72,5 kV to 550 kV The European Standard EN 50299:2002 has the status of a British Standard ICS 29.180 BS EN 50299:2002
2、 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 19 November 2002 BSI 25 January 2005 ISBN 0 580 40795 0 National foreword This British St
3、andard is the official English language version of EN 50299:2002, including Corrigendum April 2004. The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers, which has the responsibility to: A list of organizations represented on this committee can be o
4、btained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facili
5、ty of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations.
6、 aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages
7、 This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments 15517 Corrigendum No. 1 25 Janua
8、ry 2005 Figure 2 replacement of column U maxwith ?UEUROPEAN STANDARD EN 50299 NORME EUROPENNE EUROPISCHE NORM November 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secreta
9、riat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50299:2002 E ICS 29.180 Incorporating Corrigendum April 2004 English version Oil-immersed cable connection assemblies for transformer
10、s and reactors having highest voltage for equipment U mfrom 72,5 kV to 550 kV Bote de raccordement de cble pour transformateurs immergs et bobine dinductance de tensions comprises entre 72,5 kV et 550 kV lgefllte Kabelanschlusseinheiten fr Transformatoren und Drosselspulen mit einer hchsten Spannung
11、 fr Betriebsmittel U mvon 72,5 kV bis 550 kV This European Standard was approved by CENELEC on 2002-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alte
12、ration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t
13、ranslation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Gre
14、ece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 50299:2002 2 Foreword This European Standard was prepared by the CENELEC Technical Committee TC 14, Power transformers. The text of the draft was submi
15、tted to the formal vote and was approved by CENELEC as EN 50299 on 2002-10-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-10-01 - latest date by which the national
16、 standards conflicting with the EN have to be withdrawn (dow) 2005-10-01 _ 3 EN 50299:2002 Contents 1 Scope.4 2 Normative references4 3 Definitions.5 4 Limits of supply. 6 5 Rated values6 6 Preferred values6 6.1 Highest voltage for equipment 6 6.2 Rated current6 7 Requirements.6 7.1 Temperature of c
17、onnection interface 6 7.2 Mechanical requirements . 7 7.3 Standard dimensions . 7 7.4 Disconnecting link 7 7.5 Protection against corrosion. 7 7.6 Mechanical forces on cable terminations 8 8 Tests 8 8.1 Factory tests.8 8.2 Tests after installation 8 Figure 1 Limits of supply for transformer end term
18、inal and cable termination.10 Figure 2 Standard dimensions for cable connection assembly.11 EN 50299:2002 4 1 Scope This standard covers the oil-immersed single-phase connection assembly of cables for transformers and reactors, designed in accordance with EN 60076 series and with EN 60289, respectiv
19、ely. NOTE In the standard the term “transformer“ is used as common definition for transformer and reactor. The purpose of EN 50299 is to establish for the cable assemblies: the electrical and mechanical requirements, including interchangeability; the limits of supply; the test to be carried out. It
20、complements and amends, if necessary, the relevant IEC standards and applies to oil immersed cable connections, suitable for fluid-filled or dry-type cable terminations. EN 50299 does not cover direct cable terminations (see 3.3.3), but, in this case, upon agreement between purchaser and supplier, t
21、he standard may be used for guidance except for Figure 1 and Figure 2 which are not applicable. This standard applies to oil-immersed cable connection boxes on transformers with highest voltage for equipment U m= 72,5 kV to 550 kV, including the current conductor terminal at the cable sealing end of
22、 the transformer. 2 Normative references This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amen
23、dments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 60076 Series Power transformers (IEC 60076 series, mo
24、d.) EN 60289 Reactors (IEC 60289, mod.) IEC 60141 Series Test on oil-filled and gas-pressure cables and their accessories IEC 60296 Specification for unused mineral insulating oils for transformers and switchgear IEC 60840 Power cables with extruded insulation and their accessories for rated voltage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN502992002OILIMMERSEDCABLECONNECTIONASSEMBLIESFORTRANSFORMERSANDREACTORSHAVINGHIGHESTVOLTAGEFOREQUIPMENTUMFROM725KVTO550KVUDOWNM

链接地址:http://www.mydoc123.com/p-574777.html