BS EN 50292-2013 Electrical apparatus for the detection of carbon monoxide in domestic premises caravans and boats Guide on the selection installation use and maintenance《探测家庭居室、大篷.pdf
《BS EN 50292-2013 Electrical apparatus for the detection of carbon monoxide in domestic premises caravans and boats Guide on the selection installation use and maintenance《探测家庭居室、大篷.pdf》由会员分享,可在线阅读,更多相关《BS EN 50292-2013 Electrical apparatus for the detection of carbon monoxide in domestic premises caravans and boats Guide on the selection installation use and maintenance《探测家庭居室、大篷.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 50292:2013Electrical apparatus for thedetection of carbon monoxidein domestic premises, caravansand boats Guide on theselection, installation, use andmaintenanceBS EN 50292:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50292
2、:2013. Itsupersedes BS EN 50292:2002 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EXL/31/1, Gas detectors.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include al
3、l the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 57013 1ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standa
4、rd was published under the authority of theStandards Policy and Strategy Committee on 30 November 2013.Amendments issued since publicationDate Text affectedBS EN 50292:2013EUROPEAN STANDARD EN 50292 NORME EUROPENNE EUROPISCHE NORM August 2013 CENELEC European Committee for Electrotechnical Standardi
5、zation Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50292:2013 E ICS 1
6、3.320 Supersedes EN 50292:2001 English version Electrical apparatus for the detection of carbon monoxide in domestic premises, caravans and boats - Guide on the selection, installation, use and maintenance Appareils lectriques pour la dtection de monoxyde de carbone dans les locaux usage domestique,
7、 caravanes et bateaux - Guide de slection, dinstallation, dutilisation et de maintenance Elektrische Gerte fr die Detektion von Kohlenmonoxid in Wohnhusern, Caravans und Booten - Leitfaden fr Auswahl, Installation, Benutzung und Instandhaltung This European Standard was approved by CENELEC on 2013-0
8、7-15. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obt
9、ained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified
10、to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greec
11、e, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 50292:2013EN 50292:2013 - 2 - Contents Page Foreword . 3 Introduction . 4 1 Scope 5 2 No
12、rmative references 5 3 Terms and definitions . 5 4 Sources of carbon monoxide . 7 4.1 General information 7 4.2 Normal exposure levels 7 4.3 Burning of carbonaceous materials for heating and cooking 7 4.4 Uncontrolled burning 8 4.5 Tobacco smoking 8 4.6 Internal combustion engines 8 4.7 Migration of
13、 CO 8 5 Installation 8 5.1 General . 8 5.2 Location of the apparatus . 8 5.3 Types of apparatus 10 6 Executive functions (type A apparatus only) 11 6.1 General . 11 6.2 Shut-off valve . 11 6.3 Ventilation fan 11 6.4 Mains electrical switch 11 6.5 Remote alarm . 11 6.6 Additional visual alarm . 12 6.
14、7 Link between detector and ancillary device . 12 7 Advice to the user 12 7.1 Use of alarm . 12 7.2 Manufacturers instructions . 12 7.3 Location 12 7.4 Power supply . 12 7.5 Indicators 12 7.6 Alarms . 13 7.7 Maintenance . 13 7.8 Lifetimes . 13 8 Emergency actions 13 Annex A (informative) Health effe
15、cts . 15 A.1 Toxic effects . 15 A.2 Chronic effects on high risk groups 16 A.3 Normal COHb levels 17 A.4 Tobacco smoking 17 Annex B (informative) Philosophy of setting alarm points . 18 Bibliography 20 BS EN 50292:2013- 3 - EN 50292:2013 Foreword This document (EN 50292:2013) has been prepared by CL
16、C/TC 216, “Gas detectors“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-07-15 latest date by which the national standards conflicting with this document have to
17、be withdrawn (dow) 2016-07-15 This document supersedes EN 50292:2001. EN 50292:2013 includes the following significant technical changes with respect to EN 50292:2001 (various minor changes have also been made). Title and definitions are revised to be more general, i.e. to cover domestic premises, b
18、oats and caravans. This is a result of the splitting of EN 50291 into EN 50291-1 and EN 50291-2. In 4.3.1 of EN 50292:2001, incorrect terminology “warm air systems“ is replaced by “ducted air heaters“ (in 4.3.2 of EN 50292:2013). In 4.7, a more general title replaces the previous one as CO migration
19、 applies not only to multi-occupancy and multi-storey buildings but also to any premises connected to other premises, such as semi-detached and terrace premises, where the migration of CO is possible. In 5.2.1 and 5.2.2, the use of caravans and boats is included in installation/location information.
20、 In 5.3, an additional type of apparatus is added, capable of identifying lower concentrations of CO than would be needed to trigger an alarm. Such features are available in certain products, and may be useful to some at-risk groups, especially people who have respiratory health issues. In 6.2, the
21、text is modified so that triggering a shut-off valve should be on the main gas supply, ideally at the gas meter/cylinder outlet, so that the entire installation is isolated (and not only individual appliances as stated in the previous version), as the source may not be that appliance. In 6.4, the te
22、xt is modified to state that it is more important that the gas supply is isolated rather than the electrical supply. There is no need to make an exception for a gas appliance with an electrical connection. The carbon monoxide detection apparatus should not be used to operate the mains electrical swi
23、tch, since such action may create unnecessary hazard for occupants of the premises. A new subclause 7.1 “Use of alarm“ is added. It includes the requirement to advise the user that a CO alarm does not replace the correct installation, commissioning and regular maintenance by a competent person. This
24、 is required in the instruction booklet by EN 50291-1:2010, 4.7.4, item n. NOTE This was already stated in the introduction to EN 50292 but it is emphasised in the new 7.1. In 7.5, text relating to hydrogen interference is added. In Clause 8, recommendation to isolate the emergency control valve for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN502922013ELECTRICALAPPARATUSFORTHEDETECTIONOFCARBONMONOXIDEINDOMESTICPREMISESCARAVANSANDBOATSGUIDEONTHESELECTIONINSTALLATIONUSEANDMAINTENANCE

链接地址:http://www.mydoc123.com/p-574774.html